Perforation of the small intestine caused by fixation plate penetration into the abdomen
The authors report a case of intestinal loop penetration and peritonitis caused by penetration of the tip of the fixation into the abdominal cavity after internal fixation of an unstable intertrochanteric fracture. Complete regression of acute infection was achieved by suturing the intestinal wound,...
Saved in:
Published in: | Der Unfallchirurg Vol. 97; no. 10; p. 545 |
---|---|
Main Authors: | , |
Format: | Journal Article |
Language: | English |
Published: |
Germany
01-10-1994
|
Subjects: | |
Online Access: | Get more information |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The authors report a case of intestinal loop penetration and peritonitis caused by penetration of the tip of the fixation into the abdominal cavity after internal fixation of an unstable intertrochanteric fracture. Complete regression of acute infection was achieved by suturing the intestinal wound, removing the internal fixation device and administering systemic and local antibiotic therapy. |
---|---|