Influence of cavity disinfectant and adhesive systems on the bonding procedure in demineralized dentin - a one-year in vitro evaluation

To evaluate the influence of a 2% chlorhexidine solution (CHX) on the bond strength and nano leakage of two self-etching adhesive systems on demineralized dentin over a 12-month period. The middle dentin from sound third molars was exposed and demineralized in vitro. Twelve groups were formed using...

Full description

Saved in:
Bibliographic Details
Published in:The journal of adhesive dentistry Vol. 14; no. 6; p. 575
Main Authors: Sacramento, Patrícia A, de Castilho, Aline R, Banzi, Efani C, Puppi-Rontani, Regina Maria
Format: Journal Article
Language:English
Published: Germany 01-12-2012
Subjects:
Online Access:Get more information
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract To evaluate the influence of a 2% chlorhexidine solution (CHX) on the bond strength and nano leakage of two self-etching adhesive systems on demineralized dentin over a 12-month period. The middle dentin from sound third molars was exposed and demineralized in vitro. Twelve groups were formed using different adhesive systems (Clearfil Protect Bond [PB], Clearfil SE Bond [SE]) dentin treatment (with or without CHX application), and water-storage times (24 h, 6 and 12 months). Composite resin cylinders were bonded to the prepared dentin, and these specimens underwent microshear bond strength (µSBS) testing and nano leakage evaluation. µSBS data were submitted to a three-way ANOVA and Tukey's test. The failure mode and nano leakage were analyzed descriptively by score. There was a statistically significant interaction only between the adhesive system and CHX, and adhesive system and water-storage times. SE showed the lowest µSBS just at 24 h water-storage time regardless of CHX. A significant decrease in µSBS values after 6 months of water storage occurred in all of the groups and was maintained until 12 months. Adhesive failure increased with storage time. All groups showed nano leakage at the resin/dentin interfaces and an increased silver deposition was noticed after 6 and 12 months of water storage. The highest percentages of nano leakage were found in CHX groups. CHX did not interfere with µSBS values for either self-etching adhesive system, but water storage did. Bond strength decreased for both adhesive systems after 6 and 12 months, regardless of CHX application. Nano leakage increased with water-storage time and with CHX application.
AbstractList To evaluate the influence of a 2% chlorhexidine solution (CHX) on the bond strength and nano leakage of two self-etching adhesive systems on demineralized dentin over a 12-month period. The middle dentin from sound third molars was exposed and demineralized in vitro. Twelve groups were formed using different adhesive systems (Clearfil Protect Bond [PB], Clearfil SE Bond [SE]) dentin treatment (with or without CHX application), and water-storage times (24 h, 6 and 12 months). Composite resin cylinders were bonded to the prepared dentin, and these specimens underwent microshear bond strength (µSBS) testing and nano leakage evaluation. µSBS data were submitted to a three-way ANOVA and Tukey's test. The failure mode and nano leakage were analyzed descriptively by score. There was a statistically significant interaction only between the adhesive system and CHX, and adhesive system and water-storage times. SE showed the lowest µSBS just at 24 h water-storage time regardless of CHX. A significant decrease in µSBS values after 6 months of water storage occurred in all of the groups and was maintained until 12 months. Adhesive failure increased with storage time. All groups showed nano leakage at the resin/dentin interfaces and an increased silver deposition was noticed after 6 and 12 months of water storage. The highest percentages of nano leakage were found in CHX groups. CHX did not interfere with µSBS values for either self-etching adhesive system, but water storage did. Bond strength decreased for both adhesive systems after 6 and 12 months, regardless of CHX application. Nano leakage increased with water-storage time and with CHX application.
Author de Castilho, Aline R
Banzi, Efani C
Puppi-Rontani, Regina Maria
Sacramento, Patrícia A
Author_xml – sequence: 1
  givenname: Patrícia A
  surname: Sacramento
  fullname: Sacramento, Patrícia A
  organization: State University of Campinas, Piracicaba Dental School, Piracicaba, Brazil
– sequence: 2
  givenname: Aline R
  surname: de Castilho
  fullname: de Castilho, Aline R
– sequence: 3
  givenname: Efani C
  surname: Banzi
  fullname: Banzi, Efani C
– sequence: 4
  givenname: Regina Maria
  surname: Puppi-Rontani
  fullname: Puppi-Rontani, Regina Maria
BackLink https://www.ncbi.nlm.nih.gov/pubmed/23240110$$D View this record in MEDLINE/PubMed
BookMark eNo1UMtOwzAQ9KGIlsKNM_IPpPiROM4RVTwqVeIC52pjb6irxI5ip1L4AX6bIOA0mtHMrHauyMIHj4TccraRomL3p80J7AaELiVbkBXPFc8KrosluYrxxJjUrCwuyVJIkTPO2Yp87XzTjugN0tBQA2eXJmpddL5Bk8AnCt5SsEeM7ow0TjFhF2nwNB2R1sFb5z9oPwSDdhyQOk8tds7jAK37RDszn2YxozCHMJsQhh_TfGcIFM_QjpBc8NfkooE24s0frsn70-Pb9iXbvz7vtg_7rBecp6yUlitpuFa5bnLNEGxtjVIVV7Ut61pKJkpdmYYpMz-fCwOoS1VpWchyXkKsyd1vbz_WHdpDP7gOhunwv4j4Bk0BZHs
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.3290/j.jad.a28730
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: ECM
  name: MEDLINE
  url: https://search.ebscohost.com/login.aspx?direct=true&db=cmedm&site=ehost-live
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Dentistry
ExternalDocumentID 23240110
Genre Journal Article
GroupedDBID ---
34H
53G
5GY
ABJNI
ACGFO
AENEX
AFFNX
ALMA_UNASSIGNED_HOLDINGS
C94
CGR
CUY
CVF
EBD
EBS
ECM
EIF
EJD
F5P
GROUPED_DOAJ
NPM
OK1
P2P
RQP
ID FETCH-LOGICAL-p211t-73d163c18648f480eadbdc66916bd7bb3302789cf06c46142cae8769835375182
ISSN 1461-5185
IngestDate Sat Sep 28 08:34:25 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 6
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-p211t-73d163c18648f480eadbdc66916bd7bb3302789cf06c46142cae8769835375182
PMID 23240110
ParticipantIDs pubmed_primary_23240110
PublicationCentury 2000
PublicationDate 2012-12-01
PublicationDateYYYYMMDD 2012-12-01
PublicationDate_xml – month: 12
  year: 2012
  text: 2012-12-01
  day: 01
PublicationDecade 2010
PublicationPlace Germany
PublicationPlace_xml – name: Germany
PublicationTitle The journal of adhesive dentistry
PublicationTitleAlternate J Adhes Dent
PublicationYear 2012
SSID ssj0038075
Score 2.0770326
Snippet To evaluate the influence of a 2% chlorhexidine solution (CHX) on the bond strength and nano leakage of two self-etching adhesive systems on demineralized...
SourceID pubmed
SourceType Index Database
StartPage 575
SubjectTerms Analysis of Variance
Chlorhexidine - pharmacology
Dental Bonding
Dental Leakage
Dental Stress Analysis
Dentin - pathology
Disinfectants - pharmacology
Drug Interactions
Humans
Resin Cements - pharmacology
Shear Strength
Statistics, Nonparametric
Tooth Demineralization - pathology
Water
Title Influence of cavity disinfectant and adhesive systems on the bonding procedure in demineralized dentin - a one-year in vitro evaluation
URI https://www.ncbi.nlm.nih.gov/pubmed/23240110
Volume 14
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lj9MwELZaOMBlxfuN5sCtMuThuskRtUXLAYTYReK2cmJbG8QmEe0elj_A32bGjhNTCQEHLlZrt3bi-TSe8bwYe2FMlteyElxV5ZILYQ0vJDa1MDJLK5sYS9HIxyer95-LzVZsZ7NQs23q-6-Uxj6kNUXO_gO1x0mxAz8jzbFFqmP7V3R_G6qOOIdx5UpD6Gbnna7U4FCu9Llxfus-kXMwGSyqzge5uGNNk23BOcteNC43dfMdpVMX2Nsu-ELhnwy_okRA-B3X-dZFucNjoZegGGWoGBd3U-32kyPyiarJV6x1pZ1c9QBnx98gfqY7V20Wa4WM6ev5EKFDcvLk9oiyrnNQ2FrVNtMd8IfLvm_4x67d-yJWiCuqSEGxSo2Krz7SLHIj8dxayJQvU1_zZ2TnIoJtzJuXvkTL4ZmRZ2XizowvSr9UqEB6O1EElf7CYYVkT5KW_jx6kME7DM3ZHOUxEtnX74K0kA_JoMdX8cEZ9FCv4keipNXDNAcKkBOETm-xo0GDgdceerfZzLR32I1NoOVd9mOEIHQWPAQhhiAgBCGgAAYIQtcCQhAGCMIIQWha-AWC4CEIHBQECNKPHARhguA99unN9nR9zId6H7zP0nTPV7lG7aBOCykKK4oEmVylaylRg6n0qqpysrEXZW0TWeN2iaxWBg_zEpWInKyH2X12rcV1HzLQdJ1ZJkttpRIpTmmkpXlUqcuqyMQj9sDv4Vnvk7qchd19_NuRJ-zmBMKn7LpFjmGesflOXz53NP0JNYOQrA
link.rule.ids 782
linkProvider EBSCOhost
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Influence+of+cavity+disinfectant+and+adhesive+systems+on+the+bonding+procedure+in+demineralized+dentin+-+a+one-year+in+vitro+evaluation&rft.jtitle=The+journal+of+adhesive+dentistry&rft.au=Sacramento%2C+Patr%C3%ADcia+A&rft.au=de+Castilho%2C+Aline+R&rft.au=Banzi%2C+Efani+C&rft.au=Puppi-Rontani%2C+Regina+Maria&rft.date=2012-12-01&rft.issn=1461-5185&rft.volume=14&rft.issue=6&rft.spage=575&rft_id=info:doi/10.3290%2Fj.jad.a28730&rft_id=info%3Apmid%2F23240110&rft_id=info%3Apmid%2F23240110&rft.externalDocID=23240110
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1461-5185&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1461-5185&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1461-5185&client=summon