Stress analysis in simulation models with or without implant threads representation
This study aimed to evaluate the influence of implants with or without threads representation on the outcome of a two-dimensional finite element (FE) analysis. Two-dimensional FE models that reproduced a frontal section of edentulous mandibular posterior bone were constructed using a standard crown/...
Saved in:
Published in: | The International journal of oral and maxillofacial implants Vol. 24; no. 6; p. 1040 |
---|---|
Main Authors: | , , , |
Format: | Journal Article |
Language: | English |
Published: |
United States
01-11-2009
|
Subjects: | |
Online Access: | Get more information |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Abstract | This study aimed to evaluate the influence of implants with or without threads representation on the outcome of a two-dimensional finite element (FE) analysis.
Two-dimensional FE models that reproduced a frontal section of edentulous mandibular posterior bone were constructed using a standard crown/implant/screw system representation. To evaluate the effect of implant threads, two models were created: a model in which the implant threads were accurately simulated (precise model) and a model in which implants with a smooth surface (press-fit implant) were used (simplified model). An evaluation was performed on ANSYS software, in which a load of 133 N was applied at a 30-degree angulation and 2 mm off-axis from the long axis of the implant on the models. The Von Mises stresses were measured.
The precise model (1.45 MPa) showed higher maximum stress values than the simplified model (1.2 MPa). Whereas in the cortical bone, the stress values differed by about 36% (292.95 MPa for the precise model and 401.14 MPa for the simplified model), in trabecular bone (19.35 MPa and 20.35 MPa, respectively), the stress distribution and stress values were similar. Stress concentrations occurred around the implant neck and the implant apex.
Considering implant and cortical bone analysis, remarkable differences in stress values were found between the models. Although the models showed different absolute stress values, the stress distribution was similar. |
---|---|
AbstractList | This study aimed to evaluate the influence of implants with or without threads representation on the outcome of a two-dimensional finite element (FE) analysis.
Two-dimensional FE models that reproduced a frontal section of edentulous mandibular posterior bone were constructed using a standard crown/implant/screw system representation. To evaluate the effect of implant threads, two models were created: a model in which the implant threads were accurately simulated (precise model) and a model in which implants with a smooth surface (press-fit implant) were used (simplified model). An evaluation was performed on ANSYS software, in which a load of 133 N was applied at a 30-degree angulation and 2 mm off-axis from the long axis of the implant on the models. The Von Mises stresses were measured.
The precise model (1.45 MPa) showed higher maximum stress values than the simplified model (1.2 MPa). Whereas in the cortical bone, the stress values differed by about 36% (292.95 MPa for the precise model and 401.14 MPa for the simplified model), in trabecular bone (19.35 MPa and 20.35 MPa, respectively), the stress distribution and stress values were similar. Stress concentrations occurred around the implant neck and the implant apex.
Considering implant and cortical bone analysis, remarkable differences in stress values were found between the models. Although the models showed different absolute stress values, the stress distribution was similar. |
Author | de Sousa, Edson Antonio Capello Assunção, Wirley Gonçalves Gomes, Erica Alves Barão, Valentim Adelino Ricardo |
Author_xml | – sequence: 1 givenname: Wirley Gonçalves surname: Assunção fullname: Assunção, Wirley Gonçalves email: wirley@foa.unesp.br organization: Department of Dental materials and Prosthodontics, Araçatuba Dental School, São Paulo State University, São Paulo, Brazil. wirley@foa.unesp.br – sequence: 2 givenname: Erica Alves surname: Gomes fullname: Gomes, Erica Alves – sequence: 3 givenname: Valentim Adelino Ricardo surname: Barão fullname: Barão, Valentim Adelino Ricardo – sequence: 4 givenname: Edson Antonio Capello surname: de Sousa fullname: de Sousa, Edson Antonio Capello |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/20162107$$D View this record in MEDLINE/PubMed |
BookMark | eNo1j8tKAzEYRrOo2Iu-guQFBpK_k8u_lOINCi6q65KZJDSSyQxJBunbW6quzuo7h29NFmlMbkFWTGtoQGm5JOtSvhgDzhnckiUwLoEztSKHQ82uFGqSiecSCg2JljDM0dQwJjqM1sVCv0M90TFfOc6VhmGKJlVaT9kZW2h208XiUr2u7siNN7G4-z9uyOfz08futdm_v7ztHvfNdGnXphXoPXLLPfRaShQaesM7i0ZCL0WHbquUEGAQdS-U8m1rnZWICC33uIUNefj1TnM3OHucchhMPh__38EPL8NNmA |
ContentType | Journal Article |
DBID | CGR CUY CVF ECM EIF NPM |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: ECM name: MEDLINE url: https://search.ebscohost.com/login.aspx?direct=true&db=cmedm&site=ehost-live sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
Discipline | Dentistry |
ExternalDocumentID | 20162107 |
Genre | Journal Article |
GroupedDBID | --- 0R~ 34H 53G 5GY 5RE 8RF AAWTL ABJNI ACGFO AENEX AFFNX ALMA_UNASSIGNED_HOLDINGS C94 CGR CUY CVF EBD EBS ECM EIF EJD F5P HZ~ NPM O9- P2P RQP SJN ZGI |
ID | FETCH-LOGICAL-p210t-459ff91d1f2c8669582ca1bd9a62c65b9e377552a998c577f44ded6999241f932 |
ISSN | 0882-2786 |
IngestDate | Sat Sep 28 07:46:34 EDT 2024 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 6 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-p210t-459ff91d1f2c8669582ca1bd9a62c65b9e377552a998c577f44ded6999241f932 |
PMID | 20162107 |
ParticipantIDs | pubmed_primary_20162107 |
PublicationCentury | 2000 |
PublicationDate | 2009-11-01 |
PublicationDateYYYYMMDD | 2009-11-01 |
PublicationDate_xml | – month: 11 year: 2009 text: 2009-11-01 day: 01 |
PublicationDecade | 2000 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | The International journal of oral and maxillofacial implants |
PublicationTitleAlternate | Int J Oral Maxillofac Implants |
PublicationYear | 2009 |
SSID | ssj0021102 |
Score | 2.0479994 |
Snippet | This study aimed to evaluate the influence of implants with or without threads representation on the outcome of a two-dimensional finite element (FE) analysis.... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 1040 |
SubjectTerms | Biomechanical Phenomena Computer Simulation Dental Implants Dental Models Dental Prosthesis Design Dental Stress Analysis - methods Elastic Modulus Finite Element Analysis Humans Models, Theoretical Osseointegration Surface Properties Weight-Bearing |
Title | Stress analysis in simulation models with or without implant threads representation |
URI | https://www.ncbi.nlm.nih.gov/pubmed/20162107 |
Volume | 24 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lb9swDBaS7rBdim7d1tcGHXYzDCSuLNvHNE3TS3dJtvUWyJYEGIitIGmK_vySshS7BVqsh16UWDQEQ_xEkZRIEvILj8ZwmwpVCoucRUqFeVrgY4rZ0vNUW4fb9Sz5fZteTtik1_M5XNu-d-U09AGvMXL2DdzeDQod8B94Di1wHdr_4vusCf4QPtlIWQebsnJFuprCNy6izaztL15MLqvVEqYYq_YAz-1JQhuWVHcV2PnusqX3InZyT9hof_TEV-KhXC6NFtYh70bfae8AiW1tT-gT255bd-2_co0CamocSSzv2_uNU-MDJ1BuB6Mu7UKsO8P8FbiPllUwkhhqbzB1AKwC49-WKpiZ7cbqzBOMN8P8CSDYTDC2V8HMEz9I5gICu-ISA41cYm0n25v4bIfhrqAGK3TQ3UGAiavKQgI0Ih65UryvU58l6vakPumD2oWa-fhmZ_uDlhV5gwY_EpNQu_efGTRWsZkfkH1nkdBRA6XPpKfqL-TjJU4iFgI8JLMGUtRDipY1bSFFG0hRhBI1a-ogRR3TqYMUfQqpr-TP1WQ-vg5dLY5wBd94F7I40zobyqGOipTzLE6jQgxzmQkeFTzOM3WeJHEcCTDfizhJNGNSSQ7mB6iIGoyEb2SvNrU6IpQVEdcDkReJlCxmElRUPVSCDQrFNR-IY_K9mY_Fqkm4svAzdfIi5ZR8ajFxRj5oWM3qB-lv5PanZcQja_1xWg |
link.rule.ids | 782 |
linkProvider | EBSCOhost |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Stress+analysis+in+simulation+models+with+or+without+implant+threads+representation&rft.jtitle=The+International+journal+of+oral+and+maxillofacial+implants&rft.au=Assun%C3%A7%C3%A3o%2C+Wirley+Gon%C3%A7alves&rft.au=Gomes%2C+Erica+Alves&rft.au=Bar%C3%A3o%2C+Valentim+Adelino+Ricardo&rft.au=de+Sousa%2C+Edson+Antonio+Capello&rft.date=2009-11-01&rft.issn=0882-2786&rft.volume=24&rft.issue=6&rft.spage=1040&rft_id=info%3Apmid%2F20162107&rft_id=info%3Apmid%2F20162107&rft.externalDocID=20162107 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0882-2786&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0882-2786&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0882-2786&client=summon |