Influence of Different Ablation Frequencies on the Clinical Results of Photorefractive Keratectomy Using the Same Excimer Laser Platform: A Contralateral Eye Study
The objective of this study was to evaluate postoperative clinical outcomes of photorefractive keratectomy (PRK) using different ablation frequencies. In this prospective, contralateral eye study, 56 eyes of 28 patients with myopia or myopic astigmatism were included. PRK was performed using the MEL...
Saved in:
Published in: | Klinische Monatsblatter fur Augenheilkunde Vol. 234; no. 5; p. 706 |
---|---|
Main Authors: | , , , , , |
Format: | Journal Article |
Language: | German |
Published: |
Germany
01-05-2017
|
Subjects: | |
Online Access: | Get more information |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Abstract | The objective of this study was to evaluate postoperative clinical outcomes of photorefractive keratectomy (PRK) using different ablation frequencies.
In this prospective, contralateral eye study, 56 eyes of 28 patients with myopia or myopic astigmatism were included. PRK was performed using the MEL90 excimer laser system (Carl Zeiss Meditec, Germany). One eye of each patient was treated with a repetition rate of 250 Hz, while the other one was treated with a repetition rate of 500 Hz. The treatment pattern in the 250 Hz and 500 Hz group only differed in terms of ablation frequency; there was no difference in laser pulse energy, spot size or ablation profile. Postoperative follow-ups were at 3 and 7 days and 1, 3 and 6 months. The following parameters were assessed: Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), higher-order aberrations (HOAs), corneal re-epithelisation time and corneal haze.
Ablation depth was proportional to laser pulse counts at both frequencies. At 6 months, 100.0% of the eyes in the 250 Hz group and 96.4% in the 500 Hz group had a UDVA of 0.00 logMAR or better; 100% of the eyes in both groups were within ± 1.00D of the attempted correction. All eyes had a postoperative CDVA of 0.00 logMAR or better. There was no difference between the groups in postoperative HOAs, corneal re-epithelisation time or corneal haze.
Photorefractive keratectomy with a repetition rate of 250 Hz and 500 Hz showed comparable efficacy, safety and predictability in the correction of myopia. There were no significant complications due to the high repetition rate, such as postsurgical corneal haze. |
---|---|
AbstractList | The objective of this study was to evaluate postoperative clinical outcomes of photorefractive keratectomy (PRK) using different ablation frequencies.
In this prospective, contralateral eye study, 56 eyes of 28 patients with myopia or myopic astigmatism were included. PRK was performed using the MEL90 excimer laser system (Carl Zeiss Meditec, Germany). One eye of each patient was treated with a repetition rate of 250 Hz, while the other one was treated with a repetition rate of 500 Hz. The treatment pattern in the 250 Hz and 500 Hz group only differed in terms of ablation frequency; there was no difference in laser pulse energy, spot size or ablation profile. Postoperative follow-ups were at 3 and 7 days and 1, 3 and 6 months. The following parameters were assessed: Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), higher-order aberrations (HOAs), corneal re-epithelisation time and corneal haze.
Ablation depth was proportional to laser pulse counts at both frequencies. At 6 months, 100.0% of the eyes in the 250 Hz group and 96.4% in the 500 Hz group had a UDVA of 0.00 logMAR or better; 100% of the eyes in both groups were within ± 1.00D of the attempted correction. All eyes had a postoperative CDVA of 0.00 logMAR or better. There was no difference between the groups in postoperative HOAs, corneal re-epithelisation time or corneal haze.
Photorefractive keratectomy with a repetition rate of 250 Hz and 500 Hz showed comparable efficacy, safety and predictability in the correction of myopia. There were no significant complications due to the high repetition rate, such as postsurgical corneal haze. |
Author | Gye, H J Tandogan, T Kim, D Khoramnia, R Auffarth, G U Choi, C Y |
Author_xml | – sequence: 1 givenname: T surname: Tandogan fullname: Tandogan, T organization: International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg – sequence: 2 givenname: R surname: Khoramnia fullname: Khoramnia, R organization: International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg – sequence: 3 givenname: H J surname: Gye fullname: Gye, H J organization: Sungkyunkwan University School of Medicine, Kangbuk Samsung Hospital, Department of Ophthalmology, Seoul, Republic of Korea – sequence: 4 givenname: G U surname: Auffarth fullname: Auffarth, G U organization: International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg – sequence: 5 givenname: D surname: Kim fullname: Kim, D organization: Department of Electrical Engineering, Kyung Hee University, Seoul, Republic of Korea – sequence: 6 givenname: C Y surname: Choi fullname: Choi, C Y organization: International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/27130976$$D View this record in MEDLINE/PubMed |
BookMark | eNo1kM1OwzAQhC0EolB65Ir8AgHbcZyYW1VaqKhEBfRcOcmaWkrsYjuIPA8vSsrPZVczo29H2nN0bJ0FhC4puaYky25CQghnCSWMCHqEzihPZZJKKUdoEoIpSZamksmCnqIRy2lKZC7O0NfS6qYDWwF2Gt8ZrcGDjXhaNioaZ_HCw_shNxDwIOMO8Kwx1lSqwc8QuiaGA7neueg8aK-qaD4AP4JXEaro2h5vgrFvP-SLagHPPyvTgscrFYa5Hnq08-0tnuKZs9GrwRjgBs_7AYhd3V-gE62aAJO_PUabxfx19pCsnu6Xs-kq2VNOYyIZyzmIrJZaK8irQpUCiooTzmnGeVbmeVaoitUChCBKKE1SwkROa1awQlA2Rle_d_dd2UK93XvTKt9v_7_FvgFpiG60 |
ContentType | Journal Article |
Copyright | Georg Thieme Verlag KG Stuttgart · New York. |
Copyright_xml | – notice: Georg Thieme Verlag KG Stuttgart · New York. |
DBID | CGR CUY CVF ECM EIF NPM |
DOI | 10.1055/s-0042-102061 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: ECM name: MEDLINE url: https://search.ebscohost.com/login.aspx?direct=true&db=cmedm&site=ehost-live sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
DocumentTitleAlternate | Einfluss unterschiedlicher Ablationsfrequenzen auf die klinischen Ergebnisse bei photorefraktiver Keratektomie unter Verwendung derselben Excimer-Laser-Plattform: Ein kontralateraler Vergleich |
EISSN | 1439-3999 |
ExternalDocumentID | 27130976 |
Genre | Controlled Clinical Trial Journal Article Comparative Study |
GroupedDBID | ABJNI ALMA_UNASSIGNED_HOLDINGS CGR CUY CVF ECM EIF NPM |
ID | FETCH-LOGICAL-p141t-92274e65d9ffae7c8ab6e8c404415445b7758ac2d6e660a6af0302671d2828612 |
IngestDate | Fri Feb 23 03:52:46 EST 2024 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 5 |
Language | German |
License | Georg Thieme Verlag KG Stuttgart · New York. |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-p141t-92274e65d9ffae7c8ab6e8c404415445b7758ac2d6e660a6af0302671d2828612 |
PMID | 27130976 |
ParticipantIDs | pubmed_primary_27130976 |
PublicationCentury | 2000 |
PublicationDate | 2017-May |
PublicationDateYYYYMMDD | 2017-05-01 |
PublicationDate_xml | – month: 05 year: 2017 text: 2017-May |
PublicationDecade | 2010 |
PublicationPlace | Germany |
PublicationPlace_xml | – name: Germany |
PublicationTitle | Klinische Monatsblatter fur Augenheilkunde |
PublicationTitleAlternate | Klin Monbl Augenheilkd |
PublicationYear | 2017 |
SSID | ssib053392981 |
Score | 2.134689 |
Snippet | The objective of this study was to evaluate postoperative clinical outcomes of photorefractive keratectomy (PRK) using different ablation frequencies.
In this... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 706 |
SubjectTerms | Equipment Design Equipment Failure Analysis Female Humans Lasers, Excimer Male Photorefractive Keratectomy - instrumentation Photorefractive Keratectomy - methods Refractive Errors - diagnosis Refractive Errors - therapy Treatment Outcome Visual Acuity |
Title | Influence of Different Ablation Frequencies on the Clinical Results of Photorefractive Keratectomy Using the Same Excimer Laser Platform: A Contralateral Eye Study |
URI | https://www.ncbi.nlm.nih.gov/pubmed/27130976 |
Volume | 234 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lj9MwELZauHBBIN4v-cAtMiQhiRNuUTdQtAghdlfitnISm1Y0bbVNEP09_FFm_EjSIgQcuEStIzdu5pPnm_E8CHmuXoUiSxVnmRQxi2LuMwF6hKEuklUSpr4-PZ-f8Q-f05MiKiYT15V1GPuvkoYxkDVmzv6DtPsfhQH4DDKHK0gdrn8l93eu6wjSwBPb_qT18tIEvQFTNcHTS-kOCryZy478JHfdygR3fFxsWuxBopOovknvFIsvo4e_2XsmzABnnolGesX3atnIK-89KETdBalFIuxS3rXzWGCe88or9iZw8eAo-RSfDja23l9Eu8OFYuVG1V15eQf_cyGXq6-Y6zZ4Gdb15ovtq9xrjAWAuVmb2N8hrGivHbbz4fQr75QSNizyrXcx9nqAJu1jDF9Is1MDk2LArrLxVh5ax-hyfFquN2au6xr8qjD8GGtr7JhOUwKy5ZvS8COgbBuNlBCseT_jyZ_vHtXvdremZApsDAn7rPcnAdcGepoGtvgrLOblwVKwVLWdfmT2aPpzfovctHYLzQ3gbpNJLe-QHz3Y6EbRHmzUgY2OwEbhK0CGOrBRCzaceQQ2OgIb1WDTMxFs1IKNarBRB7bXNKcHUKMANaqhdpdcvCnOZ3Nmu36wbRAFLcvCkEcyiesM4CB5lYoykWkV-Wj5R1FccjBxRRXWiUwSXyRCgZ4KEx7U6D0Awn6PXFtv1vIBoULGZRn6SghgonUqMh6U3A_KWsYKiLN8SO6bd3q5NaVdLt3bfvTbO4_JjQGPT8h1BfuGfEqmu7p7pmX7EwAdkq0 |
link.rule.ids | 782 |
linkProvider | EBSCOhost |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Influence+of+Different+Ablation+Frequencies+on+the+Clinical+Results+of+Photorefractive+Keratectomy+Using+the+Same+Excimer+Laser+Platform%3A+A+Contralateral+Eye+Study&rft.jtitle=Klinische+Monatsblatter+fur+Augenheilkunde&rft.au=Tandogan%2C+T&rft.au=Khoramnia%2C+R&rft.au=Gye%2C+H+J&rft.au=Auffarth%2C+G+U&rft.date=2017-05-01&rft.eissn=1439-3999&rft.volume=234&rft.issue=5&rft.spage=706&rft_id=info:doi/10.1055%2Fs-0042-102061&rft_id=info%3Apmid%2F27130976&rft_id=info%3Apmid%2F27130976&rft.externalDocID=27130976 |