Calibration System Established at TBTAK UME for Infrared Ear Thermometers (IRETs)
The traceable calibration of infrared ear thermometers, which have been used intensively in the health field, has always been issue in Turkey. Moreover, the accuracy of measurements depends entirely on the information determined by the device manufacturer or suppliers on the exception of traceabilit...
Saved in:
Published in: | 2018 IEEE International Symposium on Medical Measurements and Applications (MeMeA) pp. 1 - 6 |
---|---|
Main Authors: | , , , , |
Format: | Conference Proceeding |
Language: | English |
Published: |
IEEE
01-06-2018
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Abstract | The traceable calibration of infrared ear thermometers, which have been used intensively in the health field, has always been issue in Turkey. Moreover, the accuracy of measurements depends entirely on the information determined by the device manufacturer or suppliers on the exception of traceability chain of our National Metrology Institute (TÜBİTAK UME). However, many years ago, intensive and systematic studies were conducted in America, European Union and Japan to discipline this area. A recent study has also been initiated in Turkey at TÜBİTAK UME which aims to develop a reference calibration system for Infrared (IR) Ear Thermometers. This reference system consists of custom design stirred calibration bath together with blackbody cavities in accordance with both EN and ASTM standards which can be considered as basic standards describing the requirements for the IR ear thermometer calibration system in detail. With the use of the system installed, the calibrations of the infrared ear thermometers will now be able to be performed in our institute. |
---|---|
AbstractList | The traceable calibration of infrared ear thermometers, which have been used intensively in the health field, has always been issue in Turkey. Moreover, the accuracy of measurements depends entirely on the information determined by the device manufacturer or suppliers on the exception of traceability chain of our National Metrology Institute (TÜBİTAK UME). However, many years ago, intensive and systematic studies were conducted in America, European Union and Japan to discipline this area. A recent study has also been initiated in Turkey at TÜBİTAK UME which aims to develop a reference calibration system for Infrared (IR) Ear Thermometers. This reference system consists of custom design stirred calibration bath together with blackbody cavities in accordance with both EN and ASTM standards which can be considered as basic standards describing the requirements for the IR ear thermometer calibration system in detail. With the use of the system installed, the calibrations of the infrared ear thermometers will now be able to be performed in our institute. |
Author | Karaboce, Baki Kalemci, Murat Korkmaz, Micahit Durmus, Huseyin Okan Pehlivan, Ozlem |
Author_xml | – sequence: 1 givenname: Huseyin Okan surname: Durmus fullname: Durmus, Huseyin Okan organization: Medical Metrology Laboratory, TÜBİTAK, National Metrology Institute (UME), Kocaeli, Turkey – sequence: 2 givenname: Baki surname: Karaboce fullname: Karaboce, Baki organization: Medical Metrology Laboratory, TÜBİTAK, National Metrology Institute (UME), Kocaeli, Turkey – sequence: 3 givenname: Ozlem surname: Pehlivan fullname: Pehlivan, Ozlem organization: Temperature Laboratory, TÜBİTAK, National Metrology Institute (UME), Kocaeli, Turkey – sequence: 4 givenname: Micahit surname: Korkmaz fullname: Korkmaz, Micahit organization: Temperature Laboratory, TÜBİTAK, National Metrology Institute (UME), Kocaeli, Turkey – sequence: 5 givenname: Murat surname: Kalemci fullname: Kalemci, Murat organization: Temperature Laboratory, TÜBİTAK, National Metrology Institute (UME), Kocaeli, Turkey |
BookMark | eNotj01LxDAURSMo6IzzB3STpS5akyZtkmUdqhaniFrXw2vzwlT6IUk38--n4Kzu5Vw4cFfkcpxGJOSOs5hzZp4qrDCPE8Z1rKXQmeYXZMXTpQlhkuSabEL4ZYwlmZZKsBvyuYW-azzM3TTS72OYcaBFmKHpu3BAS2Gm9XOdv9OfqqBu8rQcnQe_LAV4Wh_QD9OAM_pAH8qvog6Pt-TKQR9wc841qV-KevsW7T5ey22-izrD5ihrTaOYA8kaoxLdWGmVZMkCU6ekstC2ClOwxrYNipZrdM5osGigtRJTsSb3_9oOEfd_vhvAH_fn0-IE9b9PmQ |
ContentType | Conference Proceeding |
DBID | 6IE 6IL CBEJK RIE RIL |
DOI | 10.1109/MeMeA.2018.8438681 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Electronic Library Online IEEE Proceedings Order Plans (POP All) 1998-Present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library Online url: http://ieeexplore.ieee.org/Xplore/DynWel.jsp sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
EISBN | 1538633922 9781538633922 |
EndPage | 6 |
ExternalDocumentID | 8438681 |
Genre | orig-research |
GroupedDBID | 6IE 6IF 6IL 6IN AAJGR ABLEC ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK IEGSK OCL RIE RIL |
ID | FETCH-LOGICAL-i90t-6c9b70fa40b9728bd4d74029b75f747dacc7e5ad9dcbe3c18eff98ade9acd4e53 |
IEDL.DBID | RIE |
IngestDate | Thu Jun 29 18:39:48 EDT 2023 |
IsPeerReviewed | false |
IsScholarly | false |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-i90t-6c9b70fa40b9728bd4d74029b75f747dacc7e5ad9dcbe3c18eff98ade9acd4e53 |
PageCount | 6 |
ParticipantIDs | ieee_primary_8438681 |
PublicationCentury | 2000 |
PublicationDate | 2018-June |
PublicationDateYYYYMMDD | 2018-06-01 |
PublicationDate_xml | – month: 06 year: 2018 text: 2018-June |
PublicationDecade | 2010 |
PublicationTitle | 2018 IEEE International Symposium on Medical Measurements and Applications (MeMeA) |
PublicationTitleAbbrev | MeMeA |
PublicationYear | 2018 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
SSID | ssj0002684730 |
Score | 1.7092063 |
Snippet | The traceable calibration of infrared ear thermometers, which have been used intensively in the health field, has always been issue in Turkey. Moreover, the... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 1 |
SubjectTerms | ASTM Blackbody cavity Calibration Cavity resonators Infrared Ear Thermometers (IRETs) Stability criteria Temperature measurement Thermal stability TUBITAK UME |
Title | Calibration System Established at TBTAK UME for Infrared Ear Thermometers (IRETs) |
URI | https://ieeexplore.ieee.org/document/8438681 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1LSwMxEA62J08qrfgmBw8Kbpt2kyY5Vt3SIhUfK3grk2QCHrqVbfv_TXZrRfDiLQRCYCaPmcn3fSHkEoTqp-hlIpCLhAuG4RxElnA1MEJai6mOROHxq3x8V_dZlMm52XJhELECn2EnNqu3fLew61gq6yqeqkHkWTekVjVXa1tPiaolYbV-82KY7k5xisMI3lKdzcBfP6hUF8ho739T75P2DxOPPm3vmAOyg0WLPEdClaldR2vJcZqFKK8GuDsKK5rf5sMH-jbNaAhK6aTwZQSa0wxKGhZGOV_MIwxmSa8mL1m-vG6TfJTld-Nk8zVC8qHZKhlYbSTzwJnRsq-M406GRDB0Ch_yAwfWShTgtLMGU9tT6L1W4FCDdRxFekiaxaLAI0KFd0Jyb8GkKbdeA4AEcKznwsiwYY9JK1pj9lmLX8w2hjj5u_uU7EaD11iqM9JclWs8J42lW19U7voC0xiXiA |
link.rule.ids | 310,311,782,786,791,792,798,27936,54770 |
linkProvider | IEEE |
linkToHtml | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1LTwIxEG4UD3pSA8a3PXjQxIVCW9oeUZdAYImPNfFGuu008cBiFvj_truIMfHirWnSNJnpY2b6fV8RutZcdig4EXFgPGKcgD8HgURMdjMujAGqAlF48Com7_IxDjI5dxsuDACU4DNohmb5lm_nZhVKZS3JqOwGnvUOZ0KQiq21qagE3RK_Xr-ZMUS1EkigF-Bbsrke-usPlfIK6e__b_ID1Pjh4uGnzS1ziLYgr6PnQKnKKufhSnQcxz7OqyDuFuslTu_T3gi_JTH2YSke5q4IUHMc6wL7pVHM5rMAhFngm-FLnC5uGyjtx-nDIFp_jhB9KLKMukZlgjjNSKZER2aWWeFTQd_Jnc8QrDZGANdWWZMBNW0JzimpLShtLANOj1Atn-dwjDB3lgvmjM4oZcYprbXQ2pK29SP9lj1B9WCN6WclfzFdG-L07-4rtDtIk_F0PJyMztBeMH6FrDpHtWWxggu0vbCry9J1X_ISmtM |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2018+IEEE+International+Symposium+on+Medical+Measurements+and+Applications+%28MeMeA%29&rft.atitle=Calibration+System+Established+at+TBTAK+UME+for+Infrared+Ear+Thermometers+%28IRETs%29&rft.au=Durmus%2C+Huseyin+Okan&rft.au=Karaboce%2C+Baki&rft.au=Pehlivan%2C+Ozlem&rft.au=Korkmaz%2C+Micahit&rft.date=2018-06-01&rft.pub=IEEE&rft.spage=1&rft.epage=6&rft_id=info:doi/10.1109%2FMeMeA.2018.8438681&rft.externalDocID=8438681 |