Long-range magnetic tracking
Two magnetic trackers are described in this paper. The first one is fully magnetic and has 1 meter range. This device can measure distance with 1 mm resolution and 1 cm total accuracy. The second system is a hybrid tracker using active magnetic ranger, three optical gyros and three micromachined inc...
Saved in:
Published in: | 2012 IEEE Sensors pp. 1 - 4 |
---|---|
Main Authors: | , , |
Format: | Conference Proceeding |
Language: | English |
Published: |
IEEE
01-10-2012
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Two magnetic trackers are described in this paper. The first one is fully magnetic and has 1 meter range. This device can measure distance with 1 mm resolution and 1 cm total accuracy. The second system is a hybrid tracker using active magnetic ranger, three optical gyros and three micromachined inclinometers. It has 15 m range and for distances below 5 m the position accuracy is 50cm. The heading error is below 0.1 deg. |
---|---|
ISBN: | 9781457717666 1457717662 |
ISSN: | 1930-0395 2168-9229 |
DOI: | 10.1109/ICSENS.2012.6411065 |