The P4DI hybrid characterization results and application in the localization of radioactive spots
The P4DI CMOS and hybrid pixel detector has 1250 pixels with 400um pitch. Pixels give simultaneously the collected charge and the time of occurrence of the hit. With different combinations of gain and peaking time it can measure signal up to 218000 electrons. A detecting plane consisting of 8 hybrid...
Saved in:
Published in: | 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) pp. 1 - 3 |
---|---|
Main Authors: | , , , , , , |
Format: | Conference Proceeding |
Language: | English |
Published: |
IEEE
01-10-2017
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Abstract | The P4DI CMOS and hybrid pixel detector has 1250 pixels with 400um pitch. Pixels give simultaneously the collected charge and the time of occurrence of the hit. With different combinations of gain and peaking time it can measure signal up to 218000 electrons. A detecting plane consisting of 8 hybrids with 10000 pixels using two different bump bonding processes and Al/CdTe/Pt Schottky diodes 0.75mm and 1mm thick has been assembled. Energy resolution from the cumulative spectrum from all pixels is: 2.9KeV FWHM at 59.54 KeV, 3 KeV FWHM at 122 KeV and 5.74 KeV FWHM at 356 KeV at 23°C. Timing resolution is 7\mu {\mathrm {s}} FWHM. The detecting plane is used in experiments for the localization of radioactive sources with the aid of coded apertures. Angular resolution of 4.6° within a Fully Coded Field of View of 75°× 75° has been demonstrated. |
---|---|
AbstractList | The P4DI CMOS and hybrid pixel detector has 1250 pixels with 400um pitch. Pixels give simultaneously the collected charge and the time of occurrence of the hit. With different combinations of gain and peaking time it can measure signal up to 218000 electrons. A detecting plane consisting of 8 hybrids with 10000 pixels using two different bump bonding processes and Al/CdTe/Pt Schottky diodes 0.75mm and 1mm thick has been assembled. Energy resolution from the cumulative spectrum from all pixels is: 2.9KeV FWHM at 59.54 KeV, 3 KeV FWHM at 122 KeV and 5.74 KeV FWHM at 356 KeV at 23°C. Timing resolution is 7\mu {\mathrm {s}} FWHM. The detecting plane is used in experiments for the localization of radioactive sources with the aid of coded apertures. Angular resolution of 4.6° within a Fully Coded Field of View of 75°× 75° has been demonstrated. |
Author | Loukas, D. Papadimitropoulos, C. Kaissas, I. Lambropoulos, C. P. Kazas, I. Hatzistratis, D. Potiriadis, C. |
Author_xml | – sequence: 1 givenname: D. surname: Hatzistratis fullname: Hatzistratis, D. organization: Technological Education Institute of Sterea Ellada, Psahna - Evia, 34400, Greece – sequence: 2 givenname: I. surname: Kazas fullname: Kazas, I. organization: National Center for Scientific Research Demokritos, Institute of Nuclear and Particle Physics, Agia Paraskevi- Attiki, 15310, Greece – sequence: 3 givenname: I. surname: Kaissas fullname: Kaissas, I. organization: Greek Atomic Energy Commission, Agia Paraskevi- Attiki, Greece – sequence: 4 givenname: C. surname: Papadimitropoulos fullname: Papadimitropoulos, C. organization: Greek Atomic Energy Commission, Agia Paraskevi-Attiki, 15310, Greece – sequence: 5 givenname: C. surname: Potiriadis fullname: Potiriadis, C. organization: Greek Atomic Energy Commission, Agia Paraskevi-Attiki, 15310, Greece – sequence: 6 givenname: D. surname: Loukas fullname: Loukas, D. organization: National Center for Scientific Research Demokritos, Institute of Nuclear and Particle Physics, Agia Paraskevi- Attiki, 15310, Greece – sequence: 7 givenname: C. P. surname: Lambropoulos fullname: Lambropoulos, C. P. organization: Technological Education Institute of Sterea Ellada, Psahna - Evia, 34400, Greece |
BookMark | eNo1kMtqwzAURNXSQpM0X5CNfsDplWS9liV9GdIHJPtwLclExbWN5BbSr28g6WpgmDkwMyVXXd8FQhYMloyBvXvbbF6r1ZID00sjBbcgLsjcasOkMIpzw_UlmXCpdQGG2xsyzfkTgIMoywnB7T7Qj_KhovtDnaKnbo8J3RhS_MUx9h1NIX-3Y6bYeYrD0EZ38mNHx2O37R22_9m-oQl97I-A-BNoHvox35LrBtsc5medke3T43b1Uqzfn6vV_bqIFsaCozXKO98opZGBLIOVXiEGByCVqevGo9IKlGbS1r5Gq5xhELgRAsVx94wsTtgYQtgNKX5hOuzOh4g_kIpYQQ |
ContentType | Conference Proceeding |
DBID | 6IE 6IH CBEJK RIE RIO |
DOI | 10.1109/NSSMIC.2017.8532903 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan (POP) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Electronic Library Online IEEE Proceedings Order Plans (POP) 1998-present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library Online url: http://ieeexplore.ieee.org/Xplore/DynWel.jsp sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Physics |
EISBN | 9781538622827 1538622823 |
EISSN | 2577-0829 |
EndPage | 3 |
ExternalDocumentID | 8532903 |
Genre | orig-research |
GroupedDBID | 29I 6IE 6IF 6IH 6IK 6IL AAJGR ADZIZ ALMA_UNASSIGNED_HOLDINGS CBEJK CHZPO JC5 OCL RIE RIO |
ID | FETCH-LOGICAL-i90t-2a986dcdf667a1054e95d6aaec00568bbfda676067159bdba96c810e2833a3853 |
IEDL.DBID | RIE |
IngestDate | Wed Jun 26 19:29:01 EDT 2024 |
IsPeerReviewed | false |
IsScholarly | false |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-i90t-2a986dcdf667a1054e95d6aaec00568bbfda676067159bdba96c810e2833a3853 |
PageCount | 3 |
ParticipantIDs | ieee_primary_8532903 |
PublicationCentury | 2000 |
PublicationDate | 2017-Oct. |
PublicationDateYYYYMMDD | 2017-10-01 |
PublicationDate_xml | – month: 10 year: 2017 text: 2017-Oct. |
PublicationDecade | 2010 |
PublicationTitle | 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) |
PublicationTitleAbbrev | NSSMIC |
PublicationYear | 2017 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
SSID | ssj0020344 ssj0002685655 |
Score | 1.7174224 |
Snippet | The P4DI CMOS and hybrid pixel detector has 1250 pixels with 400um pitch. Pixels give simultaneously the collected charge and the time of occurrence of the... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 1 |
SubjectTerms | Apertures Cameras Correlation Detectors Energy resolution Time measurement |
Title | The P4DI hybrid characterization results and application in the localization of radioactive spots |
URI | https://ieeexplore.ieee.org/document/8532903 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV07a8MwEBZNoNCpj6T0jYaOVeL4IUtzk9AuIeAM3cJZDxoodontof--J9l1W-jSzQhjJB34vu903ydC7gEizWNuGeQiZnEqEgahCpkF0FHCwcmLXekiS1cvYr5wNjkPvRbGGOObz8zEPfqzfF2qxpXKpphaQumsPQepFK1Wq6-nhFwkXmPZkS1nZde5DM0COV1lGS7LtXKlk-4zv-5T8elkefy_iZyQ8bcuj677jHNKDkxxRg59E6eqRgQw5nQdz5_p64cTYlHVuzG3YkuK3Lp5qysKhaY_jq7prqAIBKlPbF_vlpbuQe9K8H9EivS3rsZks1xsHp9Yd4UC28mgZiFIwbXSlvMUEEnFRiaaAxjlLEBFnlsNPEUOkyKqyXUOkisxCwxijggiXOU5GRZlYS4I5YbnCNYU4i0VCyMhMHFirQBEiMi65CUZuX3avrcmGdtui67-Hr4mRy4UbVfcDRnW-8bckkGlmzsf1k883qMN |
link.rule.ids | 310,311,782,786,791,792,798,27936,54770 |
linkProvider | IEEE |
linkToHtml | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV3PS8MwFA46ET35YxN_m4NHu3Vtmh9nt7HhLIPt4G28JikOpJW1Pfjfm6S1KnjxVkIpSR70fd_L-74gdA8QKkpo6kHCiUcYjzwIZOClACqMKFh5sS1dLFn8wkdja5Pz0GphtNau-Uz37aM7y1e5rGypbGBSSyCstedeRBjza7VWW1EJKI-cyrKhW9bMrvEZGvpiEC-XZmG2mYv1mw_9ulHFJZTJ0f-mcox638o8vGhzzgna0dkp2ndtnLLoIjBRxwsymuHXDyvFwrL1Y67lltiw6-qtLDBkCv84vMabDBsoiF1q-3o3T_EW1CYH90_EhgCXRQ-tJuPV49RrLlHwNsIvvQAEp0qqlFIGBksRLSJFAbS0JqA8SVIFlBkWwwyuSVQCgko-9LVBHSGEZpVnqJPlmT5HmGqaGLgmDeKShGsBviZRmnIwGNHwLnGBunaf1u-1Tca62aLLv4fv0MF09Txfz2fx0xU6tGGpe-SuUafcVvoG7RaqunUh_gT2CqZY |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2017+IEEE+Nuclear+Science+Symposium+and+Medical+Imaging+Conference+%28NSS%2FMIC%29&rft.atitle=The+P4DI+hybrid+characterization+results+and+application+in+the+localization+of+radioactive+spots&rft.au=Hatzistratis%2C+D.&rft.au=Kazas%2C+I.&rft.au=Kaissas%2C+I.&rft.au=Papadimitropoulos%2C+C.&rft.date=2017-10-01&rft.pub=IEEE&rft.eissn=2577-0829&rft.spage=1&rft.epage=3&rft_id=info:doi/10.1109%2FNSSMIC.2017.8532903&rft.externalDocID=8532903 |