Analytical design of low-cost wearable servo valve using buckled tubes
Power assisted nursing care systems have received much attentions and those researches have been done actively. In such a control system, an actuator and a control valve are mounted on the human body. Designing the system, the size and weight of the valve become serious concerns. This paper presents...
Saved in:
Published in: | 2015 IEEE International Symposium on Robotics and Intelligent Sensors (IRIS) pp. 60 - 64 |
---|---|
Main Authors: | , , , |
Format: | Conference Proceeding |
Language: | English |
Published: |
IEEE
01-10-2015
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Abstract | Power assisted nursing care systems have received much attentions and those researches have been done actively. In such a control system, an actuator and a control valve are mounted on the human body. Designing the system, the size and weight of the valve become serious concerns. This paper presents a novel, low-cost and wearable servo valve using buckled tube. In the previous study, such a valve was proposed and tested. The analytical model of the valve was also reported. In this paper, the analytical design using the model is carried out. Pressure control performance of the valve is also estimated theoretically with various design parameters As a result, the suitable design parameters can be obtained from the simulation using the model of the valve. |
---|---|
AbstractList | Power assisted nursing care systems have received much attentions and those researches have been done actively. In such a control system, an actuator and a control valve are mounted on the human body. Designing the system, the size and weight of the valve become serious concerns. This paper presents a novel, low-cost and wearable servo valve using buckled tube. In the previous study, such a valve was proposed and tested. The analytical model of the valve was also reported. In this paper, the analytical design using the model is carried out. Pressure control performance of the valve is also estimated theoretically with various design parameters As a result, the suitable design parameters can be obtained from the simulation using the model of the valve. |
Author | Nasir, Abdul Koga, Keiichiro Akagi, Tetsuya Dohta, Shujiro |
Author_xml | – sequence: 1 givenname: Keiichiro surname: Koga fullname: Koga, Keiichiro email: t15rm01kk@ous.jp organization: Dept. of Intell. Mech. Eng., Okayama Univ. of Sci., Okayama, Japan – sequence: 2 givenname: Tetsuya surname: Akagi fullname: Akagi, Tetsuya email: akagi@are.ous.ac.jp organization: Dept. of Intell. Mech. Eng., Okayama Univ. of Sci., Okayama, Japan – sequence: 3 givenname: Shujiro surname: Dohta fullname: Dohta, Shujiro email: dohta@are.ous.ac.jp organization: Dept. of Intell. Mech. Eng., Okayama Univ. of Sci., Okayama, Japan – sequence: 4 givenname: Abdul surname: Nasir fullname: Nasir, Abdul email: nasir688@gmail.com organization: Dept. of Intell. Mech. Eng., Okayama Univ. of Sci., Okayama, Japan |
BookMark | eNotz9FKwzAUgOEIeqFzDyDe5AU6c5q0SS7HcFoYDHT34yQ5GcXYStN27O0V3NV398P_wG67viPGnkCsAIR9aT6az1UpoFppVUFl9A1bWm1A1VpqKJW-Z9t1h-kyth4TD5TbU8f7yFN_LnyfR34mHNAl4pmGueczppn4lNvuxN3kvxIFPk6O8iO7i5gyLa8u2GH7eti8F7v9W7NZ74q2knUBRnsXJAlURkZfBqijsFBZhSoGY7E2OqIPylpnADD-IUoJ6AglmSAX7Pk_2xLR8Wdov3G4HK9z8hfZ4kk1 |
ContentType | Conference Proceeding |
DBID | 6IE 6IL CBEJK RIE RIL |
DOI | 10.1109/IRIS.2015.7451587 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Electronic Library Online IEEE Proceedings Order Plans (POP All) 1998-Present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library Online url: http://ieeexplore.ieee.org/Xplore/DynWel.jsp sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
EISBN | 9781467371247 1467371246 9781467371230 1467371238 |
EndPage | 64 |
ExternalDocumentID | 7451587 |
Genre | orig-research |
GroupedDBID | 6IE 6IL CBEJK RIE RIL |
ID | FETCH-LOGICAL-i536-187cbd3e0a483fc2d16f091594a4fd89a687facd499b811af9b80231abea3e8d3 |
IEDL.DBID | RIE |
IngestDate | Thu Jun 29 18:36:32 EDT 2023 |
IsPeerReviewed | false |
IsScholarly | false |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-i536-187cbd3e0a483fc2d16f091594a4fd89a687facd499b811af9b80231abea3e8d3 |
PageCount | 5 |
ParticipantIDs | ieee_primary_7451587 |
PublicationCentury | 2000 |
PublicationDate | 2015-Oct. |
PublicationDateYYYYMMDD | 2015-10-01 |
PublicationDate_xml | – month: 10 year: 2015 text: 2015-Oct. |
PublicationDecade | 2010 |
PublicationTitle | 2015 IEEE International Symposium on Robotics and Intelligent Sensors (IRIS) |
PublicationTitleAbbrev | IRIS |
PublicationYear | 2015 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
Score | 1.6153833 |
Snippet | Power assisted nursing care systems have received much attentions and those researches have been done actively. In such a control system, an actuator and a... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 60 |
SubjectTerms | analytical design Mathematical model Robots servo valve using buckled tubes |
Title | Analytical design of low-cost wearable servo valve using buckled tubes |
URI | https://ieeexplore.ieee.org/document/7451587 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1LSwMxEB5sT55UWvFNDh7ddrebbLJnbbEXEduDt5LHRATpittt_76Z7FIRvHjKEAIhycBkZr75BuC2MNxJ43liuPTBQSEOSKkwMdJYblNdCoxNbBfy6VU9TIkm525fC4OIEXyGIxJjLt9VtqFQ2VjyYH2V7EFPlqqt1eoSlVlajucv8wVhtcSoW_erYUq0F7Oj_-10DMOfwjv2vDcpJ3CA6wHMInFIjDkzFwEXrPLso9oltqo3bBd0leqfGMVXKxY0Z4uM4OxvzMTErWObxmA9hOVsurx_TLr2B8m7yIskU9Ial2Oqucq9nbis8MG4i5Jr7p0qdaGk19YFl8WoLNM-DETmpg3qHJXLT6G_rtZ4BoxbYlkX4S9XIHfCKOEVNRjzk0kZJH4OA7qC1WdLcLHqTn_x9_QlHNItt4i2K-hvvhq8hl7tmpv4JN8TMI9e |
link.rule.ids | 310,311,782,786,791,792,798,27934,54767 |
linkProvider | IEEE |
linkToHtml | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1LSwMxEB5sPehJpRXf5uDRbbvdZJM9a0uLtYjtwVvJYyKC7IrbtX_fJLtUBC-eMoRASDIwmZlvvgG4SRU1XFkaKcqtc1A8ByQXGCmuNNUDmTEMTWwXfP4i7keeJud2WwuDiAF8hj0vhly-KXTlQ2V9Tp31FbwFu4zylNfVWk2qMh5k_enzdOHRWqzXrPzVMiVYjPHB__Y6hO5P6R152hqVI9jBvAPjQB0Sos7EBMgFKSx5LzaRLso12Tht9RVQxEdYC-J05wuJB7S_EhVSt4asK4VlF5bj0fJuEjUNEKI3lqRRLLhWJsGBpCKxemji1DrzzjIqqTUik6ngVmrjnBYl4lhaN3g6N6lQJihMcgztvMjxBAjVnmedud9citQwJZgVvsWYHQ4zJ9FT6PgrWH3UFBer5vRnf09fw95k-Thbzabzh3PY9zde49suoL3-rPASWqWprsLzfAPQ-pKv |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2015+IEEE+International+Symposium+on+Robotics+and+Intelligent+Sensors+%28IRIS%29&rft.atitle=Analytical+design+of+low-cost+wearable+servo+valve+using+buckled+tubes&rft.au=Koga%2C+Keiichiro&rft.au=Akagi%2C+Tetsuya&rft.au=Dohta%2C+Shujiro&rft.au=Nasir%2C+Abdul&rft.date=2015-10-01&rft.pub=IEEE&rft.spage=60&rft.epage=64&rft_id=info:doi/10.1109%2FIRIS.2015.7451587&rft.externalDocID=7451587 |