AC losses in first and second generation high T/sub c/ tapes and MgB/sub 2/ tapes

Technical and economical assessments for future power applications of High T/sub c/ superconductivity require the evaluation and comparison of AC losses in first and second generation high T/sub c/ tapes. An electrical and a thermometric method were developed and used to measure transport AC loss in...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on applied superconductivity Vol. 15; no. 2; pp. 2847 - 2850
Main Authors: Ginocchio, S., Perini, E., Jakomin, R., Fontana, F., Zannella, S., Martini, L.
Format: Journal Article
Language:English
Published: IEEE 01-06-2005
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Technical and economical assessments for future power applications of High T/sub c/ superconductivity require the evaluation and comparison of AC losses in first and second generation high T/sub c/ tapes. An electrical and a thermometric method were developed and used to measure transport AC loss in OPIT Bi-2223/Ag tapes, Y-123 coated conductors and in new MgB/sub 2/-based superconductors, simulating the AC conditions typical of power devices. The results were compared with analytical models for AC losses calculation. The effect of the magnetic substrates used in coated conductors was also investigated and a simple calculation model was proposed.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:1051-8223
1558-2515
DOI:10.1109/TASC.2005.848245