Quantitative analysis of myocardial motion in cardiac magnetic resonance imaging using covariance function

The extraction of additional quantitative features are needed in cardiac magnetic resonance (CMR) exam to characterize the regional wall motion abnormalities related to several cardiac pathologies. The aim of this study is to present a method for myocardial wall motion analysis based on the covarian...

Full description

Saved in:
Bibliographic Details
Published in:2017 International Conference on Engineering & MIS (ICEMIS) pp. 1 - 6
Main Authors: Benameur, Narjes, Kraiem, Tarek, Arous, Younes, ben Abdallah, Nejmeddine
Format: Conference Proceeding
Language:English
Published: IEEE 01-05-2017
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract The extraction of additional quantitative features are needed in cardiac magnetic resonance (CMR) exam to characterize the regional wall motion abnormalities related to several cardiac pathologies. The aim of this study is to present a method for myocardial wall motion analysis based on the covariance function. We tested the proposed method on cine MRI images related to 26 subjects (12 with myocardial infarction, 5 with myocarditis, 5 healthy subjects and 4 with dilated cardiomyopathy (CMD)) with age ranging from 19 to 80. The outcomes of this study show that the proposed image based on the covariance image is able to represent a tool to identify the location, the transmurality of wall motion abnormalities related to different cardiac pathologies. Therefore, this technique is likely to provide additional information to CMR clinical practice.
AbstractList The extraction of additional quantitative features are needed in cardiac magnetic resonance (CMR) exam to characterize the regional wall motion abnormalities related to several cardiac pathologies. The aim of this study is to present a method for myocardial wall motion analysis based on the covariance function. We tested the proposed method on cine MRI images related to 26 subjects (12 with myocardial infarction, 5 with myocarditis, 5 healthy subjects and 4 with dilated cardiomyopathy (CMD)) with age ranging from 19 to 80. The outcomes of this study show that the proposed image based on the covariance image is able to represent a tool to identify the location, the transmurality of wall motion abnormalities related to different cardiac pathologies. Therefore, this technique is likely to provide additional information to CMR clinical practice.
Author Kraiem, Tarek
Arous, Younes
ben Abdallah, Nejmeddine
Benameur, Narjes
Author_xml – sequence: 1
  givenname: Narjes
  surname: Benameur
  fullname: Benameur, Narjes
  organization: Laboratery of Biophys. & Med. Technol., Univ. of Tunis El Manar, Tunis, Tunisia
– sequence: 2
  givenname: Tarek
  surname: Kraiem
  fullname: Kraiem, Tarek
  organization: Laboratery of Biophys. & Med. Technol., Univ. of Tunis El Manar, Tunis, Tunisia
– sequence: 3
  givenname: Younes
  surname: Arous
  fullname: Arous, Younes
  organization: Mil. Hosp. of Instruction of Tunis, Tunis, Tunisia
– sequence: 4
  givenname: Nejmeddine
  surname: ben Abdallah
  fullname: ben Abdallah, Nejmeddine
  organization: Mil. Hosp. of Instruction of Tunis, Tunis, Tunisia
BookMark eNotUNtOAjEQrUYTEfkCXvoDi9Pd7bZ9NASFBGOM-kym3VlSAq3ZLiT79y7Cy5nMuUxO5pHdhRiIsamAmRBgnlfzxfvqa5aDUDOdq9wofcMmAwoJBiqltLplo1wqmYki1w9sktIOAAphACSM2O7ziKHzHXb-RBwD7vvkE48NP_TRYVt73PND7HwM3Ad-YRw_4DZQ5x1vKcWAwRH3A-fDlh_TGV08Yev_heYY3Dn_xO4b3CeaXOeY_bwuvufLbP3xtpq_rDMvlOwyV5WWyrKolSaLUA5bbXVubSEkSm1qIxsCDU5JUUlr6nrwlMJKI7VCqooxm17ueiLa_LZDsbbfXL9T_AEHvF1H
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/ICEMIS.2017.8272978
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume
IEEE Xplore All Conference Proceedings
IEEE Electronic Library Online
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library Online
  url: http://ieeexplore.ieee.org/Xplore/DynWel.jsp
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
EISBN 9781509067787
1509067787
EISSN 2575-1328
EndPage 6
ExternalDocumentID 8272978
Genre orig-research
GroupedDBID 6IE
6IF
6IL
6IN
AAJGR
ABLEC
ADZIZ
ALMA_UNASSIGNED_HOLDINGS
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CBEJK
CHZPO
IEGSK
OCL
RIE
RIL
ID FETCH-LOGICAL-i175t-c64be443d78eba044bedb82bb315a589d95fe080c75165b9dd04441b59587ae63
IEDL.DBID RIE
IngestDate Wed Jun 26 19:24:27 EDT 2024
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i175t-c64be443d78eba044bedb82bb315a589d95fe080c75165b9dd04441b59587ae63
PageCount 6
ParticipantIDs ieee_primary_8272978
PublicationCentury 2000
PublicationDate 2017-May
PublicationDateYYYYMMDD 2017-05-01
PublicationDate_xml – month: 05
  year: 2017
  text: 2017-May
PublicationDecade 2010
PublicationTitle 2017 International Conference on Engineering & MIS (ICEMIS)
PublicationTitleAbbrev ICEMIS
PublicationYear 2017
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0003190050
ssj0001968510
Score 1.6706824
Snippet The extraction of additional quantitative features are needed in cardiac magnetic resonance (CMR) exam to characterize the regional wall motion abnormalities...
SourceID ieee
SourceType Publisher
StartPage 1
SubjectTerms cardiac magnetic resonance
covariance
Heart
Image segmentation
Magnetic resonance
Magnetic resonance imaging
Motion segmentation
Myocardium
quantification
wall motion abnormalities
Title Quantitative analysis of myocardial motion in cardiac magnetic resonance imaging using covariance function
URI https://ieeexplore.ieee.org/document/8272978
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV09T8MwELVoJ1j4aBHf8sCI26SJY99cWpUFgQoSW2XHdlVEkwoaJP49PidqQWJhix0lin1W7s6-9x4h19xFLtEmZsY4xdJUAQNwhrkoxzNfoWVIFCdTcf8ib0dIk3OzwcJYa0Pxme3hZTjLN2Ve4VZZXw58KChki7QEyBqrtd1PgcwHD9Gm7ZcWcps0RENxBP27oR_ZFKu5RK950y9JleBRxvv_-5YD0t1C8-jDxukckh1bHJG9H6yCHfL6WKkiYMf8n4yqhnWElo4uv7znwhXxRmv1HrooaN2T06WaF4hopD4BL5GGw9LFMmgYUSyOn9O8_PSJdbiB3hCf75Ln8ehpOGGNpAJb-DhhzfIs1TZNEyOk1SpKfctoOdA6ibniEgxwZ30QmQseZ1yDMcgnF2sOXApls-SYtIuysCeEgvM21ahWrJE1UEFmIXEwcKmIwMnolHRw1marmjVj1kzY2d_d52QXDVOXEl6Q9vq9spek9WGqq2Dnb7kHqhc
link.rule.ids 310,311,782,786,791,792,798,27934,54767
linkProvider IEEE
linkToHtml http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV3PT8IwFG4UD-rFH2D8bQ8eHWysXdszQiAi0YCJN9KuLcHIZpSZ-N_b1y2giRdva5cta1-z9177vu9D6Jra0MZKR4HWVgaESBEIYXVgwxTOfJniPlHsj9nomd92gSbnZoWFMcb44jPThEt_lq_ztICtshZvu1CQ8U20RQlLWInWWu-oiMSFD-Gq7RYXsJtUVENRKFqDjhvbGOq5WLN61y9RFe9Tenv_-5p91FiD8_DDyu0coA2THaLdH7yCdfTyWMjMo8fcvwzLincE5xYvvpzvgjXxikv9HjzPcNmT4oWcZYBpxC4Fz4GIw-D5wqsYYSiPn-E0_3Sptb8B_hCeb6CnXnfS6QeVqEIwd5HCMkgTogwhsWbcKBkS19KKt5WKIyopF1pQa1wYmTIaJVQJrYFRLlJUUM6kSeIjVMvyzBwjLKyzqgK9YgW8gVIkRsRWtC1hobA8PEF1mLXpW8mbMa0m7PTv7iu03Z_cD6fDwejuDO2AkcrCwnNUW74X5gJtfuji0tv8G9lyrWg
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2017+International+Conference+on+Engineering+%26+MIS+%28ICEMIS%29&rft.atitle=Quantitative+analysis+of+myocardial+motion+in+cardiac+magnetic+resonance+imaging+using+covariance+function&rft.au=Benameur%2C+Narjes&rft.au=Kraiem%2C+Tarek&rft.au=Arous%2C+Younes&rft.au=ben+Abdallah%2C+Nejmeddine&rft.date=2017-05-01&rft.pub=IEEE&rft.eissn=2575-1328&rft.spage=1&rft.epage=6&rft_id=info:doi/10.1109%2FICEMIS.2017.8272978&rft.externalDocID=8272978