Use of RF-based technique as a metrology tool for TSV reliability analysis

In this work, radio frequency (RF) based measurement technique is used as a prognostic tool for the assessment of the effect of thermal cycling on the reliability of through-silicon via (TSV) stacked dies. It was found that RF signal integrity in TSV daisy chains degraded with thermal cycling. Focus...

Full description

Saved in:
Bibliographic Details
Published in:2013 IEEE 63rd Electronic Components and Technology Conference pp. 186 - 191
Main Authors: Okoro, Chukwudi, Kabos, Pavel, Obrzut, Jan, Hummler, Klaus, Obeng, Yaw S.
Format: Conference Proceeding
Language:English
Published: IEEE 01-05-2013
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In this work, radio frequency (RF) based measurement technique is used as a prognostic tool for the assessment of the effect of thermal cycling on the reliability of through-silicon via (TSV) stacked dies. It was found that RF signal integrity in TSV daisy chains degraded with thermal cycling. Focused ion beam (FIB) based failure analysis, showed that the root cause for this trend was due to the formation and propagation of voids with thermal cycling.
ISBN:9781479902330
1479902330
ISSN:0569-5503
2377-5726
DOI:10.1109/ECTC.2013.6575570