Radiation Dosimetry for Indium-111-Pentetreotide
We present radiation dose estimates for 111In-pentetreotide. Kinetic data were gathered in 10 subjects at two different sites. A compartmental model was used to fit the data, including retention, in three major organs and excretion. The data were consistent for the subjects at both sites. The organ...
Saved in:
Published in: | The Journal of nuclear medicine (1978) Vol. 38; no. 12; pp. 1919 - 1922 |
---|---|
Main Authors: | , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Reston, VA
Soc Nuclear Med
01-12-1997
Society of Nuclear Medicine |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | We present radiation dose estimates for 111In-pentetreotide.
Kinetic data were gathered in 10 subjects at two different sites. A compartmental model was used to fit the data, including retention, in three major organs and excretion.
The data were consistent for the subjects at both sites. The organ receiving the highest dose was the kidneys (0.52 mGy/MBq); the effective dose equivalent was 0.1 mSv/MBq, and the effective dose was 0.073 mSv/MBq.
The results of this study provide the basis for evaluation of radiation safety of this drug. |
---|---|
ISSN: | 0161-5505 1535-5667 |