Influence of intraaortic balloon pump counterpulsation on transesophageal echocardiography derived determinants of diastolic function

Intraaortic balloon pump counterpulsation (IABP) is often used in patients with acute coronary syndrome for its favourable effects on left ventricular (LV) systolic function and coronary perfusion. However, the effects of IABP on LV diastolic function have not been comprehensively investigated. Acut...

Full description

Saved in:
Bibliographic Details
Published in:PloS one Vol. 10; no. 3; p. e0118788
Main Authors: Nowak-Machen, Martina, Hilberath, Jan N, Rosenberger, Peter, Schmid, Eckhard, Memtsoudis, Stavros G, Angermair, Johannes, Tuli, Jayshree K, Shernan, Stanton K
Format: Journal Article
Language:English
Published: United States Public Library of Science 04-03-2015
Public Library of Science (PLoS)
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Intraaortic balloon pump counterpulsation (IABP) is often used in patients with acute coronary syndrome for its favourable effects on left ventricular (LV) systolic function and coronary perfusion. However, the effects of IABP on LV diastolic function have not been comprehensively investigated. Acute diastolic dysfunction has been linked to increased morbidity and mortality. The aim of this study was to examine the influence of IABP on LV diastolic dysfunction using standard TEE derived parameters. Intraoperative TEE was performed in 10 patients (mean age 65 ± 11 yrs) undergoing urgent coronary artery bypass graft surgery (CABG), who had received an IABP preoperatively. TEE derived measures of diastolic dysfunction included early to late transmitral Doppler inflow velocity ratio (E/A), deceleration time (Dt), pulmonary venous systolic to diastolic Doppler velocity ratio (S/D), transmitral propagation velocity (Vp), and the ratio of early to late mitral annular tissue Doppler velocities (e'/a'). Statistical analyses included the Wilcoxon Sign-Rank test, and a p<0.05 was considered significant. Transmitral inflow E/A ratios increased significantly from 0.86 to 1.07 (p < 0.05), while Dt decreased significantly from 218 to 180 ms (p < 0.05) with the use of IABP. Significant increases in Vp (34 cm/s to 43 cm/s; p < 0.05), and e'/a' (0.58 to 0.71; p < 0.05) suggested a favourable influence of intraaortic counterpulsation on diastolic function. The use of perioperative IABP significantly improves TEE derived parameters of diastolic function consistent with a favourable impact on LV relaxation in cardiac surgery patients undergoing CABG.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Competing Interests: The authors have read the journal’s policy and the authors of this manuscript have the following competing interests: Stanton K. Shernan is editor of E-echocardiography.com and a lecturer at Philips, Healthcare, Inc.
Conceived and designed the experiments: MNM JNH SKS PR. Performed the experiments: MNM SGM PR. Analyzed the data: MNM JKT ES JA. Wrote the paper: MNM JNH SKS.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0118788