Displacements of fiducial markers in patients with prostate cancer treated with image guided radiotherapy: A single-institution descriptive study
Abstract Aim To describe daily displacements when using fiducial markers as surrogates for the target volume in patients with prostate cancer treated with IGRT. Background The higher grade of conformity achieved with the use of modern radiation technologies in prostate cancer can increase the risk o...
Saved in:
Published in: | Reports of practical oncology and radiotherapy Vol. 20; no. 1; pp. 38 - 42 |
---|---|
Main Authors: | , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Netherlands
Elsevier Urban & Partner Sp. z.o.o
01-01-2015
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Abstract Aim To describe daily displacements when using fiducial markers as surrogates for the target volume in patients with prostate cancer treated with IGRT. Background The higher grade of conformity achieved with the use of modern radiation technologies in prostate cancer can increase the risk of geographical miss; therefore, an associated protocol of IGRT is recommended. Materials and methods A single-institution, retrospective, consecutive study was designed. 128 prostate cancer patients treated with daily on-line IGRT based on 2D kV orthogonal images were included. Daily displacement of the fiducial markers was considered as the difference between the position of the patient when using skin tattoos and the position after being relocated using fiducial markers. Measures of central tendency and dispersion were used to describe fiducial displacements. Results The implant itself took a mean time of 15 min. We did not detect any complications derived from the implant. 4296 sets of orthogonal images were identified, 128 sets of images corresponding to treatment initiation were excluded; 91 (2.1%) sets of images were excluded from the analysis after having identified that these images contained extreme outlier values. If IGRT had not been performed 25%, 10% or 5% of the treatments would have had displacements superior to 4, 7 or 9 mm respectively in any axis. Conclusions Image guidance is required when using highly conformal techniques; otherwise, at least 10% of daily treatments could have significant displacements. IGRT based on fiducial markers, with 2D kV orthogonal images is a convenient and fast method for performing image guidance. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 Centro de Control de Cancer, Bogota, Colombia. |
ISSN: | 1507-1367 2083-4640 |
DOI: | 10.1016/j.rpor.2014.08.002 |