Tibialis anterior analysis from functional and architectural perspective during isometric foot dorsiflexion: a cross‐sectional study of repeated measures

Background The purpose of the present study is to establish the relationship and degree of contribution between torque and sonomiography variables (pennation angle – muscle thickness), and electromyography variables (EMGAreaUnderCurve – EMGMaximalPeak) of the tibialis anterior muscle during (TA) max...

Full description

Saved in:
Bibliographic Details
Published in:Journal of foot and ankle research Vol. 8; no. 1; pp. 74 - n/a
Main Authors: Ruiz Muñoz, Maria, González‐Sánchez, Manuel, Cuesta‐Vargas, Antonio I.
Format: Journal Article
Language:English
Published: London BioMed Central 18-12-2015
BioMed Central Ltd
Wiley
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background The purpose of the present study is to establish the relationship and degree of contribution between torque and sonomiography variables (pennation angle – muscle thickness), and electromyography variables (EMGAreaUnderCurve – EMGMaximalPeak) of the tibialis anterior muscle during (TA) maximal and relative isometric foot dorsiflexion (IFD). Secondary aim: To determine the measurement's reliability. Methods Cross‐sectional study. 31 participants (15 men; 16 women) performed IFD at different intensities (100, 75, 50, and 25 %) of the maximal voluntary contraction (MVC) (three times for each intensity). Outcome variables: To determine the torque, pennation angle, muscle thickness, EMGMaximalPeak, and EMGAreaUnderCurve. Statistical analysis: In order to test the measurement's reliability, Cronbach's alpha and standard error of the measurement were determined. An inferential analysis was carried out using Pearson correlations(r). For each contraction intensity, a multiple regression analysis was performed, where the dependent variable was torque and the independent variables were EMGAreaUnderCurve, EMGMaximalPeak, muscle thickness and pennation angle. Results All outcome variables show excellent reliability. The highest correlation value was 0.955 (thickness 100 % – thickness 25 %). R2 values ranged from 0.713 (100 % MVC) to 0.588 (25 % MVC). Conclusion The outcome variables demonstrated excellent reliability in terms of measuring IFD at different intensities. The correlations between all outcome variables were moderate‐to‐strong. TA functional and architectural variables have a significant impact on the torque variance during IFD at different intensities.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1757-1146
1757-1146
DOI:10.1186/s13047-015-0132-3