Episiotomy characteristics and risks for obstetric anal sphincter injuries: a case-control study

Please cite this paper as: Stedenfeldt M, Pirhonen J, Blix E, Wilsgaard T, Vonen B, Øian P. Episiotomy characteristics and risks for obstetric anal sphincter injuries: a case‐control study. BJOG 2012;119:724–730. Objectives  To investigate the association between the geometrical properties of episio...

Full description

Saved in:
Bibliographic Details
Published in:BJOG : an international journal of obstetrics and gynaecology Vol. 119; no. 6; pp. 724 - 730
Main Authors: Stedenfeldt, M, Pirhonen, J, Blix, E, Wilsgaard, T, Vonen, B, Øian, P
Format: Journal Article
Language:English
Published: Oxford, UK Blackwell Publishing Ltd 01-05-2012
Blackwell
Wiley Subscription Services, Inc
Blackwell Science Ltd
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Please cite this paper as: Stedenfeldt M, Pirhonen J, Blix E, Wilsgaard T, Vonen B, Øian P. Episiotomy characteristics and risks for obstetric anal sphincter injuries: a case‐control study. BJOG 2012;119:724–730. Objectives  To investigate the association between the geometrical properties of episiotomy and obstetric anal sphincter injuries (OASIS) because episiotomies angled at 40–60° are associated with fewer OASIS than episiotomies with more acute angles. Design  Case–control study. Setting  University Hospital of North Norway, Tromsø and Nordland Hospital, Bodø, Norway. Sample  Seventy‐four women who had one vaginal birth and episiotomy. Cases (n = 37) have sustained OASIS at birth, while controls (n = 37) had not. The groups were matched for instrumental delivery. Methods  Two groups of women with history of only one vaginal birth were compared. Episiotomy scar was identified and photographed and relevant measures were taken. Data were analysed using conditional logistic analysis. Main outcome measures  Mean episiotomy angle, length, depth, incision point. Results  The risk of sustaining OASIS decreased by 70% (odds ratio [OR] 0.30; 95% CI 0.14–0.66) for each 5.5‐mm increase in episiotomy depth, decreased by 56% (OR 0.44; 95% CI 0.23–0.86) for each 4.5‐mm increase in the distance from the midline to the incision point of the episiotomy, and decreased by 75% (OR 0.25; 95% CI 0.10–0.61) for each 5.5‐mm increase in episiotomy length. Lastly, there was no difference in mean angle between groups but there was a “U‐shaped” association between angle and OASIS (OR 2.09; 95% CI 1.02–4.28) with an increased risk (OR 9.00; 95% CI 1.1–71.0) of OASIS when the angle was either smaller than 15°or >60°. Conclusion  The present study showed that scarred episiotomies with depth > 16 mm, length > 17 mm, incision point > 9 mm lateral of midpoint and angle range 30–60° are significantly associated with less risk of OASIS. Shrinkage of tissue must be considered.
Bibliography:ArticleID:BJO3293
istex:F2B4C95F9DA3E7A5F039B4F810192F8176844595
ark:/67375/WNG-27J4M5GW-W
http://wileyonlinelibrary.com/onlineopen#OnlineOpen_Terms
Re‐use of this article is permitted in accordance with the Terms and Conditions set out at
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Please cite this paper as: Stedenfeldt M, Pirhonen J, Blix E, Wilsgaard T, Vonen B, Øian P. Episiotomy characteristics and risks for obstetric anal sphincter injuries: a case-control study. BJOG 2012;119:724–730.
ISSN:1470-0328
1471-0528
DOI:10.1111/j.1471-0528.2012.03293.x