Real-time sonoelastography using an external reference material: test–retest reliability of healthy Achilles tendons
Objective To establish the test–retest reliability of sonoelastography (SE) on healthy Achilles tendons in contracted and relaxed states using an external reference system. Materials and Methods Forty-eight Achilles tendons from 24 healthy volunteers were assessed using ultrasound and real-time SE w...
Saved in:
Published in: | Skeletal radiology Vol. 45; no. 8; pp. 1045 - 1052 |
---|---|
Main Authors: | , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Berlin/Heidelberg
Springer Berlin Heidelberg
01-08-2016
Springer Springer Nature B.V |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Objective
To establish the test–retest reliability of sonoelastography (SE) on healthy Achilles tendons in contracted and relaxed states using an external reference system.
Materials and Methods
Forty-eight Achilles tendons from 24 healthy volunteers were assessed using ultrasound and real-time SE with an external reference material. Tendons were analyzed under relaxed and contracted conditions. Strain ratios between the tendons and the reference material were calculated. The intraclass correlation coefficient (ICC
2.k
) and Bland–Altman plot were used to assess test–retest reliability.
Results
The reliability of SE measurements under relaxed conditions ranged from high to very high, with an ICC
2.k
of 0.84 (95 % CI: 0.64–0.92) for reference material, 0.91 (95 % CI: 0.83–0.95) for Achilles tendons and 0.95 (95 % CI: 0.91–0.97) for Kager fat pads (KFP). The ICC
2.k
value for skin was 0.30 (95 % CI: –0.26 to 0.61). Reliability for measurements in the contracted state ranged from high to very high, with an ICC
2.k
of 0.93 (95 % CI: 0.87–0.96) for reference material, 0.72 (95 % CI: 0.50–0.84) for skin, 0.93 (95 % CI: 0.87–0.96) for Achilles tendons, and 0.81 (95 % CI: 0.66–0.89) for KFP. Reliability of the strain ratio (tendon/reference) under relaxed conditions was high with an ICC
2.k
of 0.87 (95 % CI: 0.75–0.93), and in the contracted state, it was very high with an ICC
2.k
of 0.94 (95 % CI: 0.90–0.97).
Conclusion
Sonoelastography using an external reference material is a reliable and simple technique for the assessment of the elasticity of healthy Achilles tendons. The use of an external material as a reference, along with strain ratios, could provide a quantitative measure of elasticity. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0364-2348 1432-2161 |
DOI: | 10.1007/s00256-016-2382-y |