Impact of Distal Protection with Filter-Type Device on Long-term Outcome after Percutaneous Coronary Intervention for Acute Myocardial Infarction: Clinical Results with Filtrap

Aim: Although distal embolization during percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI) deteriorates cardiac function, whether distal protection (DP) can improve prognosis is still controversial. We investigated whether a filter-type DP device, Filtrap®, could improve...

Full description

Saved in:
Bibliographic Details
Published in:Journal of Atherosclerosis and Thrombosis Vol. 23; no. 12; pp. 1313 - 1323
Main Authors: Teramoto, Ryota, Sakata, Kenji, Miwa, Kenji, Matsubara, Takao, Yasuda, Toshihiko, Inoue, Masaru, Okada, Hirofumi, Kanaya, Honin, Kawashiri, Masa-aki, Yamagishi, Masakazu, Hayashi, Kenshi
Format: Journal Article
Language:English
Published: Japan Japan Atherosclerosis Society 01-12-2016
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Aim: Although distal embolization during percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI) deteriorates cardiac function, whether distal protection (DP) can improve prognosis is still controversial. We investigated whether a filter-type DP device, Filtrap®, could improve long-term outcomes after PCI for AMI.Method: We studied 164 patients (130 men, mean age: 65.7 years) who underwent PCI. Patients were divided into two groups based on the use of Filtrap®. The occurrence of congestive heart failure (CHF) and major adverse cardiac events (MACE) defined as cardiac death, recurrent AMI, and target vessel revascularization were compared.Result: Between DP (n=53, 41 men, mean age: 65.5 years) and non-DP (n=111, 89 men, mean age: 65.8 years) groups, although there was significantly greater plaque area in the DP group than in the non-DP group, there were no significant differences in coronary reperfusion flow after PCI. Interestingly, patients with CHF in the non-DP group exhibited a higher CK level than those in the DP group. During a 2-year follow-up period, cumulative CHF was significantly lower in the DP group than in the non-DP group (log-rank p=0.018), and there was no significant difference in the MACE rate (log-rank p=0.238). The use of DP device could not predict MACE, but could predict CHF by multivariate analysis (odds ratio=0.099, 95% CI: 0.02–0.42, p=0.005).Conclusion: These results demonstrate that favorable clinical outcomes could be achieved by the filter-type DP device in AMI, particularly in patients with CHF.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1340-3478
1880-3873
DOI:10.5551/jat.34215