CO2 driven endotracheal tube cuff control in critically ill patients: A randomized controlled study

To determine the safety and clinical efficacy of an innovative integrated airway system (AnapnoGuard™ 100 system) that continuously monitors and controls the cuff pressure (Pcuff), while facilitating the aspiration of subglottic secretions (SS). This was a prospective, single centre, open-label, ran...

Full description

Saved in:
Bibliographic Details
Published in:PloS one Vol. 12; no. 5; p. e0175476
Main Authors: De Pascale, Gennaro, Pennisi, Mariano Alberto, Vallecoccia, Maria Sole, Bello, Giuseppe, Maviglia, Riccardo, Montini, Luca, Di Gravio, Valentina, Cutuli, Salvatore Lucio, Conti, Giorgio, Antonelli, Massimo
Format: Journal Article
Language:English
Published: United States Public Library of Science 11-05-2017
Public Library of Science (PLoS)
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To determine the safety and clinical efficacy of an innovative integrated airway system (AnapnoGuard™ 100 system) that continuously monitors and controls the cuff pressure (Pcuff), while facilitating the aspiration of subglottic secretions (SS). This was a prospective, single centre, open-label, randomized, controlled feasibility and safety trial. The primary endpoint of the study was the rate of device related adverse events (AE) and serious AE (SAE) as a result of using AnapnoGuard (AG) 100 during mechanical ventilation. Secondary endpoints were: (1) mechanical complications rate (2) ICU staff satisfaction; (3) VAP occurrence; (4) length of mechanical ventilation; (5) length of Intensive Care Unit stay and mortality; (6) volume of evacuated subglottic secretions. Sixty patients were randomized to be intubated with the AG endotracheal-tube (ETT) and connected to the AG 100 system allowing Pcuff adjustment and SS aspiration; or with an ETT combined with SS drainage and Pcuff controlled manually. No difference in adverse events rate was identified between the groups. The use of AG system was associated with a significantly higher incidence of Pcuff determinations in the safety range (97.3% vs. 71%; p<0.01) and a trend to a greater volume of aspirated SS secretions: (192.0[64-413] ml vs. 150[50-200], p = 0.19 (total)); (57.8[20-88.7] ml vs. 50[18.7-62] ml, p = 0.11 (daily)). No inter-group difference was detected using AG system vs. controls in terms of post-extubation throat pain level (0 [0-2] vs. 0 [0-3]; p = 0.7), hoarseness (42.9% vs. 75%; p = 0.55) and tracheal mucosa oedema (16.7% vs. 10%; p = 0.65). Patients enrolled in the AG group had a trend to reduced VAP risk of ventilator-associated pneumonia(VAP) (14.8% vs. 40%; p = 0.06), which were more frequently monomicrobial (25% vs. 70%; p = 0.03). No statistically significant difference was observed in duration of mechanical ventilation, ICU stay, and mortality. The use AG 100 system and AG tube in critically ill intubated patients is safe and effective in Pcuff control and SS drainage. Its protective role against VAP needs to be confirmed in a larger randomized trial. ClinicalTrials.gov NCT01550978. Date of registration: February 21, 2012.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-News-1
ObjectType-Feature-3
content type line 23
Competing Interests: The authors have declared that no competing interests exist.
Conceptualization: GDP MAP GC MA.Data curation: VDG SLC MSV.Formal analysis: GDP.Funding acquisition: MA GC.Investigation: GDP GB RM LM.Methodology: GDP MA.Project administration: GDP MA.Resources: GC MA.Software: GDP MA.Supervision: GC MA.Validation: GC MA.Visualization: GDP MA.Writing – original draft: GDP.Writing – review & editing: MA GC MAP.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0175476