Histological and Histomorphometric Evaluation of Zirconia Dental Implants Modified by Femtosecond Laser versus Titanium Implants: An Experimental Study in Fox Hound Dogs

Purpose This study applied femtosecond laser technology to zirconia dental implants (Bredent GmbH & Co.KG, Senden, Germany) to generate a surface texture of microgrooves over the entire intraosseous surface, analyzing its behavior in an in vivo model in comparison with titanium implants with san...

Full description

Saved in:
Bibliographic Details
Published in:Clinical implant dentistry and related research Vol. 17; no. 3; pp. 525 - 532
Main Authors: Calvo-Guirado, Jose Luis, Aguilar-Salvatierra, Antonio, Delgado-Ruiz, Rafael Arcesio, Negri, Bruno, Fernández, María Piedad Ramírez, Maté Sánchez de Val, José Eduardo, Gómez-Moreno, Gerardo, Romanos, Georgios E.
Format: Journal Article
Language:English
Published: United States Blackwell Publishing Ltd 01-06-2015
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Purpose This study applied femtosecond laser technology to zirconia dental implants (Bredent GmbH & Co.KG, Senden, Germany) to generate a surface texture of microgrooves over the entire intraosseous surface, analyzing its behavior in an in vivo model in comparison with titanium implants with sandblasted and acid‐etched surfaces. Materials and Methods The study used six American Fox Hound dogs. Each received four implants per hemi‐mandible, making a total of eight implants per animal. The 48 immediate loaded implants were divided into two groups of 24 titanium implants (control group) and 24 zirconia implants (study/test group), distributed randomly. Bone‐to‐implant contact (BIC) values and crestal resorption were determined at 1 and 3 months, also measuring calcium, phosphorous, and carbon concentrations by means of energy dispersive x‐ray. Results BIC percentages after 30 days were 51.36% for titanium implants and 44.68% for zirconia implants. After 90 days, values increased to 61.73% in titanium and 47.94% in zirconia implants. After 30 days, there was more crestal bone lost in the titanium group (0.77 mm) compared with the zirconia group (0.01 mm). After 90 days, zirconia implants showed greater marginal bone resorption (1.25 mm) compared with the titanium group (0.37 mm). Conclusions The present study shows that zirconia implants with modified surfaces can produce good osseointegration values when compared with titanium implants in terms of BIC and crestal bone resorption at 1 and 3 months.
Bibliography:ArticleID:CID12162
ark:/67375/WNG-PTW337T4-G
istex:B149F8630AF2B007967BD9E99B933E0D286F35A8
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1523-0899
1708-8208
DOI:10.1111/cid.12162