Analysis of inorganic cations in biological samples by the combination of micro-electrodialysis and capillary electrophoresis with capacitively coupled contactless conductivity detection

Micro-electrodialysis (μED) and CE were combined for rapid pretreatment and subsequent determination of inorganic cations in biological samples. Combination of μED with CE greatly improved the analytical performance of the latter as the adsorption of high molecular weight compounds present in real s...

Full description

Saved in:
Bibliographic Details
Published in:Electrophoresis Vol. 32; no. 3-4; pp. 464 - 471
Main Authors: Doan, Thi Kieu Oanh, Kubáň, Pavel, Kubáň, Petr, Kiplagat, Isaac K, Boček, Petr
Format: Journal Article
Language:English
Published: Weinheim Wiley-VCH Verlag 01-02-2011
WILEY-VCH Verlag
WILEY‐VCH Verlag
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Micro-electrodialysis (μED) and CE were combined for rapid pretreatment and subsequent determination of inorganic cations in biological samples. Combination of μED with CE greatly improved the analytical performance of the latter as the adsorption of high molecular weight compounds present in real samples on the inner capillary wall was eliminated. Fifty microliter of 80-fold diluted human body fluids such as plasma, serum and whole blood was used in the donor compartment of the μED system requiring less than 1 μL of the original body fluid per analysis. Inorganic cations that migrated through a cellulose acetate dialysis membrane with molecular weight cut-off value of 500 Da were collected in the acceptor solution and were then analyzed using CE-C⁴D. Baseline separation of inorganic cations was achieved in a BGE solution consisting of 12.5 mM maleic acid, 15 mM L-arginine and 3 mM 18-crown-6 at pH 5.5. Repeatability of the CE-C⁴D method was better than 0.5% and 2.5% for migration times and peak areas, respectively; limits of detection of all inorganic cations in the presence of 2 mM excess of Na⁺ were around 1 μM and calibration curves were linear with correlation coefficients better than 0.998. Repeatability of the sample pretreatment procedure was calculated for six independent electrodialysis runs of artificial and real samples and was better than 11.8%. Recovery values between 96.3 and 110% were achieved for optimized electrodialysis conditions of standard solutions and real samples; lifetime of the dialysis membranes for pretreatment of real samples was estimated to 100 runs.
Bibliography:http://dx.doi.org/10.1002/elps.201000423
Grant Agency of the Czech Republic - No. P206/10/1219; No. 203/08/1536
Academy of Sciences of the Czech Republic (Institute Research Funding) - No. AV0Z40310501
istex:8DA6198BCE8FB7127BB07A8990F52671F36D5265
ArticleID:ELPS201000423
Grant Agency of the Academy of Sciences of the Czech Republic - No. IAA 400310703
ark:/67375/WNG-D8GPS48B-X
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Article-2
ObjectType-Feature-1
ISSN:0173-0835
1522-2683
1522-2683
DOI:10.1002/elps.201000423