Microcatheter Re-Shaping Using Fusion Image in Coil Embolization: A Technical Note
Objective: We report the utility of microcatheter reshaping by referring to fusion images with 3D-DSA and microcatheter 3D images made using non-subtraction and non-contrast (non-SC) rotational images.Case Presentations: Case 1: The patient was a 74-year-old man who had an internal carotid-anterior...
Saved in:
Published in: | Journal of Neuroendovascular Therapy Vol. 15; no. 11; pp. 755 - 761 |
---|---|
Main Authors: | , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
The Japanese Society for Neuroendovascular Therapy
01-01-2021
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Abstract | Objective: We report the utility of microcatheter reshaping by referring to fusion images with 3D-DSA and microcatheter 3D images made using non-subtraction and non-contrast (non-SC) rotational images.Case Presentations: Case 1: The patient was a 74-year-old man who had an internal carotid-anterior choroidal artery bifurcation aneurysm with a tortuous proximal parent artery. The initial attempt to introduce the microcatheter into the aneurysm was unsuccessful. During this unsuccessful microcatheter introduction, we created fusion images with 3D-DSA and microcatheter 3D images by acquiring positional information of the microcatheter using the non-SC method. By reshaping the microcatheter with reference to the fusion images, the direction of the distal end of the microcatheter was reshaped to be in accordance with the long axis of the aneurysm, a shape more suitable for coiling. Case 2: The patient was a 47-year-old man who had an anterior communicating (A-com) artery aneurysm with two daughter sacs. We successfully placed two microcatheters in the direction of each sac to make more stable framing by referring to 3D fusion images after the first microcatheter was positioned. In both cases, microcatheter reshaping was necessary because of the vessel and aneurysm anatomy. We have used this technique successfully in 15 patients, for both ruptured and unruptured aneurysms. The average number of microcatheter reshaping was 1.3 times.Conclusion: This method provides effective microcatheter reshaping for coil embolization of aneurysms, particularly those with differences between the axis of the parent artery and the vertical axis of aneurysm, or with a tortuous proximal artery. |
---|---|
AbstractList | Objective: We report the utility of microcatheter reshaping by referring to fusion images with 3D-DSA and microcatheter 3D images made using non-subtraction and non-contrast (non-SC) rotational images.Case Presentations: Case 1: The patient was a 74-year-old man who had an internal carotid-anterior choroidal artery bifurcation aneurysm with a tortuous proximal parent artery. The initial attempt to introduce the microcatheter into the aneurysm was unsuccessful. During this unsuccessful microcatheter introduction, we created fusion images with 3D-DSA and microcatheter 3D images by acquiring positional information of the microcatheter using the non-SC method. By reshaping the microcatheter with reference to the fusion images, the direction of the distal end of the microcatheter was reshaped to be in accordance with the long axis of the aneurysm, a shape more suitable for coiling. Case 2: The patient was a 47-year-old man who had an anterior communicating (A-com) artery aneurysm with two daughter sacs. We successfully placed two microcatheters in the direction of each sac to make more stable framing by referring to 3D fusion images after the first microcatheter was positioned. In both cases, microcatheter reshaping was necessary because of the vessel and aneurysm anatomy. We have used this technique successfully in 15 patients, for both ruptured and unruptured aneurysms. The average number of microcatheter reshaping was 1.3 times.Conclusion: This method provides effective microcatheter reshaping for coil embolization of aneurysms, particularly those with differences between the axis of the parent artery and the vertical axis of aneurysm, or with a tortuous proximal artery. |
ArticleNumber | tn.2020-0192 |
Author | Yokota, Kazuma Srivatanakul, Kittipong Hirayama, Akihiro Sorimachi, Takatoshi Shigematsu, Hideaki Matsumae, Mitsunori |
Author_xml | – sequence: 1 fullname: Hirayama, Akihiro organization: Department of Neurosurgery, Tokai University School of Medicine, Isehara, Kanagawa, Japan – sequence: 2 fullname: Srivatanakul, Kittipong organization: Department of Neurosurgery, Tokai University School of Medicine, Isehara, Kanagawa, Japan – sequence: 3 fullname: Shigematsu, Hideaki organization: Department of Neurosurgery, Tokai University School of Medicine, Isehara, Kanagawa, Japan – sequence: 4 fullname: Yokota, Kazuma organization: Department of Neurosurgery, Tokai University School of Medicine, Isehara, Kanagawa, Japan – sequence: 5 fullname: Sorimachi, Takatoshi organization: Department of Neurosurgery, Tokai University School of Medicine, Isehara, Kanagawa, Japan – sequence: 6 fullname: Matsumae, Mitsunori organization: Department of Neurosurgery, Tokai University School of Medicine, Isehara, Kanagawa, Japan |
BookMark | eNpVkNtq3DAQhkVJodskD9A7vYC3Gh0suzclLDlBDpAm10KW5bUWr7TI2kL79JFwWFpdzFyM_u-f-b-iMx-8RegbkLWQrfy-8zatk19TQklFoKWf0IpCU1eUt_wMraBpaMWJpF_Q5TzvSH41gQb4Cr08OhOD0Wm0yUb8Yqtfoz44v8Vvc6k3x9kFj-_3emux83gT3ISv912Y3F-d8ugHvsKv1ozeGT3hp5DsBfo86Gm2lx_9HL3dXL9u7qqH59v7zdVDZbiUtKKU6Zb3vGM12IH1ndA9bdum6-q-JqzngzTStFJaxihjeqBaaE6ZZFB3Giw7Rz8X7uHY7W1vrE9RT-oQ3V7HPypop_6feDeqbfitgDAJhIhMgIWQI5jnaIeTGIgqyaqSrEpelWRVSTZrbhdNBpeTg5-ct2oXjtHna5UZRBGNRQKKEBCQW-YRKUQuNbAWGs6K-91C2s0pp3vy1jE5M9nFG4TK-lz_XeL0xYw6KuvZOzBboAI |
Cites_doi | 10.5137/1019-5149.JTN.5527-11.0 10.1007/s00701-018-3642-5 10.1016/j.compbiomed.2016.07.005 10.1177/159101991301900207 10.1227/01.NEU.0000370891.67129.2F 10.1016/j.wneu.2015.03.006 10.5797/jnet.tn.2016-0051 |
ContentType | Journal Article |
Copyright | 2021 The Japanese Society for Neuroendovascular Therapy 2021 The Japanese Society for Neuroendovascular Therapy 2021 |
Copyright_xml | – notice: 2021 The Japanese Society for Neuroendovascular Therapy – notice: 2021 The Japanese Society for Neuroendovascular Therapy 2021 |
CorporateAuthor | Tokai University School of Medicine Department of Neurosurgery |
CorporateAuthor_xml | – name: Department of Neurosurgery – name: Tokai University School of Medicine |
DBID | AAYXX CITATION 5PM |
DOI | 10.5797/jnet.tn.2020-0192 |
DatabaseName | CrossRef PubMed Central (Full Participant titles) |
DatabaseTitle | CrossRef |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
DocumentTitleAlternate | Hirayama A, et al |
EISSN | 2186-2494 |
EndPage | 761 |
ExternalDocumentID | 10_5797_jnet_tn_2020_0192 cf5jneth_2021_001511_010_0755_07613918435 article_jnet_15_11_15_tn_2020_0192_article_char_en |
GroupedDBID | ABDBF ABJNI ALMA_UNASSIGNED_HOLDINGS GROUPED_DOAJ JMI JSF JSH KQ8 MOJWN OK1 RJT RPM RZJ AAYXX CITATION 5PM |
ID | FETCH-LOGICAL-c4772-223a94d4b361ef3db5ad2998bb6d603d4f7c7c977e33233af2a5a4237316ba1e3 |
IEDL.DBID | RPM |
ISSN | 1882-4072 |
IngestDate | Tue Sep 17 21:31:14 EDT 2024 Fri Aug 23 03:22:50 EDT 2024 Fri Nov 08 06:52:52 EST 2024 Sun Jul 28 05:07:45 EDT 2024 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 11 |
Language | English |
License | This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c4772-223a94d4b361ef3db5ad2998bb6d603d4f7c7c977e33233af2a5a4237316ba1e3 |
Notes | Email: a-hira@is.icc.u-tokai.ac.jp |
OpenAccessLink | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10371005/ |
PageCount | 7 |
ParticipantIDs | pubmedcentral_primary_oai_pubmedcentral_nih_gov_10371005 crossref_primary_10_5797_jnet_tn_2020_0192 medicalonline_journals_cf5jneth_2021_001511_010_0755_07613918435 jstage_primary_article_jnet_15_11_15_tn_2020_0192_article_char_en |
PublicationCentury | 2000 |
PublicationDate | 20210101 |
PublicationDateYYYYMMDD | 2021-01-01 |
PublicationDate_xml | – month: 1 year: 2021 text: 20210101 day: 1 |
PublicationDecade | 2020 |
PublicationTitle | Journal of Neuroendovascular Therapy |
PublicationTitleAlternate | JNET |
PublicationYear | 2021 |
Publisher | The Japanese Society for Neuroendovascular Therapy |
Publisher_xml | – name: The Japanese Society for Neuroendovascular Therapy |
References | 1) Suzuki H, Maki H, Taki W: Evaluation of cerebral arteriovenous malformations using image fusion combining three-dimensional digital subtraction angiography with magnetic resonance imaging. Turk Neurosurg 2012; 22: 341–345. 2) Baxter BW, Rosso D, Lownie SP: Double microcatheter technique for detachable coil treatment of large, wide-necked intracranial aneurysms. AJNR Am J Neuroradiol 1998; 19: 1176–1178. 6) Kwon BJ, Im SH, Park JC, et al: Shaping and navigating methods of microcatheters for endovascular treatment of paraclinoid aneurysms. Neurosurgery 2010; 67: 34–40; discussion 40. 8) Jia ZY, Song YS, Sheen JJ, et al: Loop microcatheter technique for coil embolization of paraclinoid aneurysms. Acta Neurochir (Wien) 2018; 160: 1755–1760. 4) Namba K, Higaki A, Kaneko N, et al: Microcatheter shaping for intracranial aneurysm coiling using the 3-dimensional printing rapid prototyping technology: preliminary result in the first 10 consecutive cases. World Neurosurg 2015; 84: 178–186. 3) Ishibashi T, Takao H, Suzuki T, et al: Tailor-made shaping of microcatheters using three-dimensional printed vessel models for endovascular coil embolization. Comput Biol Med 2016; 77: 59–63. 5) Ohshima T, Imai T, Goto S, et al: A novel technique of microcatheter shaping with cerebral aneurysmal coil embolization: in vivo printing method. JNET J Neuroendvasc Ther 2016; 11: 48–52. 7) Xiaochuan H, Xiaoyun S, Youxiang L, et al: Endovascular treatment of unruptured A1 segment aneurysms. Interv Neuroradiol 2013; 19: 186–194. 1 2 3 4 5 6 7 8 |
References_xml | – ident: 2 – ident: 1 doi: 10.5137/1019-5149.JTN.5527-11.0 – ident: 8 doi: 10.1007/s00701-018-3642-5 – ident: 3 doi: 10.1016/j.compbiomed.2016.07.005 – ident: 7 doi: 10.1177/159101991301900207 – ident: 6 doi: 10.1227/01.NEU.0000370891.67129.2F – ident: 4 doi: 10.1016/j.wneu.2015.03.006 – ident: 5 doi: 10.5797/jnet.tn.2016-0051 |
SSID | ssj0000601814 ssib040212986 ssib051641539 ssib002919271 |
Score | 2.1829848 |
Snippet | Objective: We report the utility of microcatheter reshaping by referring to fusion images with 3D-DSA and microcatheter 3D images made using non-subtraction... |
SourceID | pubmedcentral crossref medicalonline jstage |
SourceType | Open Access Repository Aggregation Database Publisher |
StartPage | 755 |
SubjectTerms | coil embolization fusion image microcatheter shaping Technical Note |
Title | Microcatheter Re-Shaping Using Fusion Image in Coil Embolization: A Technical Note |
URI | https://www.jstage.jst.go.jp/article/jnet/15/11/15_tn.2020-0192/_article/-char/en http://mol.medicalonline.jp/en/journal/download?GoodsID=cf5jneth/2021/001511/010&name=0755-0761e https://pubmed.ncbi.nlm.nih.gov/PMC10371005 |
Volume | 15 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
ispartofPNX | Journal of Neuroendovascular Therapy, 2021, Vol.15(11), pp.755-761 |
link | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1NT-MwELUo4oC0QiAWbfmSD5yQ0iZxHCecqEorOIAQ7Ep7s-zYVouaFEH7_5mx06rlyCWX2I41tuM34zfPhFzlpSpMkVVRGdsiyrRjkUpFGRVcmZixXBmNicL3r-Lpf3E3QpmcfJUL40n7lZ72mlnda6YTz618r6v-iifWf34cYm5bAtOn3yEdAIcbPnr4_6IIlT9ORviICmDhOJOLUvTfwOPvLVD5NEVGVplubUh7b4DJMNn-Vx3OSYJexXfG5MYWND4kBy12pIPQxyOyY5tj8vKIlDqvvgomoi82ep0oTIKing1Ax0uMh9GHGj5Ipw0dzqczOqr1fNZmYN7QAfUBduwIfZov7G_ybzz6O7yP2osSoioDdBzBFq_KzGSa5Yl1zGgwNGwzhda5yWNmMicqUQHSs4yljCmXKq6QD8OSXKvEshOy28wb-4dQp3MnuIs11IDlXSqlBCsAh2mAZsbFXXK9spZ8D3oYEvwINK1E08pFI9G0Ek3bJYNgz3XRdhRD0YSD_4HPzTrrIph1Bku3S263hkK2a-xTVo5jMxOsmyA3D7AjNAHNCM4lxmdYibfZ8C4ptkZv3RuU1t5-AzPOS2yvZtjpz6uekX3sWAjXnJPdxcfSXpDOp1leesf_0s_aL3EU8ho |
link.rule.ids | 230,315,729,782,786,866,887,27933,27934,53800,53802 |
linkProvider | National Library of Medicine |
linkToHtml | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1ba9swFBa9DDYY68o2lu5SPfSp4MS2LMva00KWkLImlLaDvQnJkkhK7JQ1-f89x3JCsse--EUXZH26HB195xMhF7nUhS2yMpKxK6LMeBbpVMio4NrGjOXaGgwUHt-J6d_i1xBlcvJNLExD2i_NvFsvqm49nzXcyseq7G14Yr2byQBj2xIYPr1DcgwTNo53TulhBUYZquZCGQ1I1AALF5pcSNF7gDN_d4XapylysmS6tyW9egCrDMPt31bhpiQoVvzPmdzZhEYnL23-e_KuNTtpP6SfkgNXfyC3E2TjNcKt0Lv01kV3M43xU7QhEtDRGl1p9KqCltJ5TQfL-YIOK7NctMGbP2ifNr55_AM6Xa7cR_JnNLwfjKP2jYWozMCwjsA60DKzmWF54jyzBjCCHaowJrd5zGzmRSlKMBIdYylj2qeaa6TSsCQ3OnHsEzmql7X7TKg3uRfcxwZKwMogtdYCwJHcgFVnfdwhl5tuVo9BSkPBEQQxUYiJWtUKMVGISYf0AxDbrG0PhqwJh6MLfnfLbLNgwBrM-g75uYehaqfnkyo9x2pmWDZBWh-YnVAFVCM4V-jaYRIfwuEdUuzBvm0NqnLvpwDajTr3Bt2zlxc9J6_H95NrdX01_f2FvMFGBq_PV3K0-rd238jhk11_bwb9MykjBt4 |
linkToPdf | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1LbxshEEZNWlWVoj7URnXapBx6qrTeB8uy5FTLsZWojRUlrdQbggVkR9611dj_vzPL2rJzbC57WUDAx2MYvvkg5GshdWnLvIpk4sooN55FOhMyKrm2CWOFtgYDhS_vxORPeTFCmZzzTSxMS9qvzKzfzOt-M5u23MplXcUbnlh8cz3E2LYUhk-8tD4-IM9h0ibZzkk9rMIoRdVeKqMRiTpg4VKTCyniezj391eof5ohL0tme9vSi3uwzDDk_qgOtyVBteIxb3JnIxq_eUoT3pLXnflJByHNO_LMNe_J7TWy8loBV-hleuuiu6nGOCraEgroeI0uNXpVQ23prKHDxWxOR7VZzLsgznM6oK2PHltBJ4uV-0B-j0e_hpdR99ZCVOVgYEdgJWiZ29ywInWeWQNYwU5VGlPYImE296ISFRiLjrGMMe0zzTVSalhaGJ06dkwOm0XjPhLqTeEF94mBHLBCSK21AIAkN2DdWZ_0yLdNV6tlkNRQcBRBXBTiolaNQlwU4tIjgwDGNmnXiyFpyuEIg9_dPNskGLgGs79Hvu_hqLpp-qAqz7GYKeZNkd4H5icUAcUIzhW6eJjEB3F4j5R70G9rg-rc-38A8Vale4Pwyf9n_UJe3lyM1c-ryY9P5BXWMTh_PpPD1d-1OyUHD3Z91o77f3QxCV4 |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Microcatheter+Re-Shaping+Using+Fusion+Image+in+Coil+Embolization%3A+A+Technical+Note&rft.jtitle=Journal+of+neuroendovascular+therapy&rft.au=Hirayama%2C+Akihiro&rft.au=Srivatanakul%2C+Kittipong&rft.au=Shigematsu%2C+Hideaki&rft.au=Yokota%2C+Kazuma&rft.date=2021-01-01&rft.pub=The+Japanese+Society+for+Neuroendovascular+Therapy&rft.issn=1882-4072&rft.eissn=2186-2494&rft.volume=15&rft.issue=11&rft.spage=755&rft.epage=761&rft_id=info:doi/10.5797%2Fjnet.tn.2020-0192&rft.externalDBID=PMC10371005 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1882-4072&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1882-4072&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1882-4072&client=summon |