Comparison of I-gel with proseal LMA in adult patients undergoing elective surgical procedures under general anesthesia without paralysis: A prospective randomized study

We compared i-gel and ProSeal laryngeal mask airway (PLMA) regarding time taken for insertion, effective seal, fiberoptic view of larynx, ease of Ryle's tube insertion, and postoperative sore throat assessment. In a prospective, randomized manner, 48 adult patients of American Society of Anesth...

Full description

Saved in:
Bibliographic Details
Published in:Journal of anaesthesiology, clinical pharmacology Vol. 30; no. 2; pp. 183 - 187
Main Authors: Kini, Gurudas, Devanna, Gopalkrishna Mettinadka, Mukkapati, Koteswara Rao, Chaudhuri, Souvik, Thomas, Daniel
Format: Journal Article
Language:English
Published: India Medknow Publications and Media Pvt. Ltd 01-04-2014
Medknow Publications & Media Pvt Ltd
Wolters Kluwer Medknow Publications
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We compared i-gel and ProSeal laryngeal mask airway (PLMA) regarding time taken for insertion, effective seal, fiberoptic view of larynx, ease of Ryle's tube insertion, and postoperative sore throat assessment. In a prospective, randomized manner, 48 adult patients of American Society of Anesthesiologists I-II of either gender between 18 and 60 years presenting for a short surgical procedure were assigned to undergo surgery under general anesthesia on spontaneous ventilation using either the i-gel or PLMA. An experienced nonblinded anesthesiologist inserted appropriate sized i-gel or PLMA in patients using standard insertion technique and assessed the intraoperative findings of the study regarding regarding time taken for respective device insertion, effective seal, fiberoptic view of larynx, ease of Ryle's tube insertion, and postoperative sore throat assessment. Postoperative assessment of sore throat was done by blinded anesthesia resident. The time required for insertion of i-gel was lesser (21.98 ± 5.42 and 30.60 ± 8.51 s in Group I and Group P, respectively; P = 0.001). Numbers of attempts for successful insertions were comparable and in majority, device was inserted in first attempt. The mean airway leak pressures were comparable. However, there were more number of patients in Group P who had airway leak pressure >20 cm H2O. The fiberoptic view of glottis, ease of Ryle's tube insertion, and incidence of complications were comparable. Time required for successful insertion of i-gel was less in adult patients undergoing short surgical procedure under general anesthesia on spontaneous ventilation. Patients with airway leak pressure >20 cm H2O were more in PLMA group which indicates its better suitability for controlled ventilation.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0970-9185
2231-2730
DOI:10.4103/0970-9185.130008