Cardiac output measurements in congenital heart disease: validation of a simple, portable Doppler method
Noninvasive Doppler cardiac output measurements are clinical standards in adults and children. Presently, these standard Doppler methods generally require relatively expensive and large imaging equipment with complex signal‐processing techniques. Thus, universal access to these important measurement...
Saved in:
Published in: | Journal of ultrasound in medicine Vol. 20; no. 4; pp. 365 - 370 |
---|---|
Main Authors: | , , , |
Format: | Journal Article |
Language: | English |
Published: |
Laurel, MD
Am inst Ulrrasound Med
01-04-2001
American Institute of Ultrasound in Medicine |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Abstract | Noninvasive Doppler cardiac output measurements are clinical standards in adults and children. Presently, these standard Doppler methods generally require relatively expensive and large imaging equipment with complex signal‐processing techniques. Thus, universal access to these important measurements has been limited. Simple, portable Doppler methods have been validated previously and applied to infants and children without cardiac disease. Nevertheless, these specific, inexpensive techniques have not been validated in children with complex congenital heart disease. Accordingly, we compared a noninvasive, suprasternal, non‐image‐guided, pulsed Doppler cardiac output with standard invasive Fick cardiac outputs in 20 patients (age range, 1 month to 15 years) with congenital heart disease. Doppler cardiac output was displayed by multiplying the mean velocity with an operator‐selected angiographic or echographic estimate of the aortic diameter. The values from linear regression analysis were r = 0.96; Doppler cardiac output = 0.98 x Fick cardiac output ‐ 0.08 L/min (range, 0.55‐3.10 L/min). The 95% confidence limits were less than 35% of the mean of Doppler and Fick cardiac outputs across the range of measurements. We conclude that relatively linear and accurate measurements of cardiac output can be made by this simple, inexpensive, portable method in selected infants and children with various forms of congenital heart disease. |
---|---|
AbstractList | Noninvasive Doppler cardiac output measurements are clinical standards in adults and children. Presently, these standard Doppler methods generally require relatively expensive and large imaging equipment with complex signal-processing techniques. Thus, universal access to these important measurements has been limited. Simple, portable Doppler methods have been validated previously and applied to infants and children without cardiac disease. Nevertheless, these specific, inexpensive techniques have not been validated in children with complex congenital heart disease. Accordingly, we compared a noninvasive, suprasternal, non-image-guided, pulsed Doppler cardiac output with standard invasive Fick cardiac outputs in 20 patients (age range, 1 month to 15 years) with congenital heart disease. Doppler cardiac output was displayed by multiplying the mean velocity with an operator-selected angiographic or echographic estimate of the aortic diameter. The values from linear regression analysis were r = 0.96; Doppler cardiac output = 0.98 x Fick cardiac output - 0.08 L/min (range, 0.55-3.10 L/min). The 95% confidence limits were less than 35% of the mean of Doppler and Fick cardiac outputs across the range of measurements. We conclude that relatively linear and accurate measurements of cardiac output can be made by this simple, inexpensive, portable method in selected infants and children with various forms of congenital heart disease. |
Author | Gentles, T. L Caulder, A. L Neutze, J. M Greene, E. R |
Author_xml | – sequence: 1 fullname: Gentles, T. L – sequence: 2 fullname: Neutze, J. M – sequence: 3 fullname: Caulder, A. L – sequence: 4 fullname: Greene, E. R |
BackLink | http://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=928938$$DView record in Pascal Francis https://www.ncbi.nlm.nih.gov/pubmed/11316315$$D View this record in MEDLINE/PubMed |
BookMark | eNqFkEtv1DAUhS1URKeFH8AGWUJ0RQa_EieIDZryVBEburZuYqdx5cTBdoj67_Eoo7Jkcy1dfef43HOBziY_GYReUrKXdcXf3S_jnhFC89iLPa_KJ2hHy5IUTUX5GdoRJutCsEaeo4sY7wlhhErxDJ1TymnFablDwwGCttBhv6R5SXg0EJdgRjOliO2EOz_dmckmcHgwEBLWNmbEvMd_wFkNyfoJ-x4DjnacnXmLZx8StM7gaz_nRciWafD6OXrag4vmxem9RLefP_06fC1ufn75dvh4U3RCirKoRENkS2ipOdOag9R1r1sgtdBUNpXglJlK17ylDeE1rSSwvme6qvsGhCCMX6KrzXcO_vdiYlKjjZ1xDibjl6ikJFLk8zNIN7ALPsZgejUHO0J4UJSoY70q16uO9eahhMr1Zs2rk_nSjkb_U5z6zMDrEwCxA9cHmDobH7mG1Q2vM_Vho1brzMP__1Xfb38cF4yILcWbTT7Yu2G1wag4gnM5E1Xruj6m_Qu6qKPo |
CODEN | JUMEDA |
CitedBy_id | crossref_primary_10_1097_ACO_0000000000000408 crossref_primary_10_1007_s12630_014_0265_z crossref_primary_10_1097_00005237_200604000_00013 crossref_primary_10_1007_s10877_015_9757_9 |
ContentType | Journal Article |
Copyright | 2016 by the American Institute of Ultrasound in Medicine 2001 INIST-CNRS |
Copyright_xml | – notice: 2016 by the American Institute of Ultrasound in Medicine – notice: 2001 INIST-CNRS |
DBID | IQODW CGR CUY CVF ECM EIF NPM AAYXX CITATION 7X8 |
DOI | 10.7863/jum.2001.20.4.365 |
DatabaseName | Pascal-Francis Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed CrossRef MEDLINE - Academic |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) CrossRef MEDLINE - Academic |
DatabaseTitleList | MEDLINE - Academic CrossRef MEDLINE |
Database_xml | – sequence: 1 dbid: ECM name: MEDLINE url: https://search.ebscohost.com/login.aspx?direct=true&db=cmedm&site=ehost-live sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine Physics |
EISSN | 1550-9613 |
EndPage | 370 |
ExternalDocumentID | 10_7863_jum_2001_20_4_365 11316315 928938 JUM2001204365 www20_4_365 |
Genre | article Journal Article Comparative Study |
GroupedDBID | - 0R 1KJ 1OC 34G 39C 53G 55 5GY 5RE 5VS AAWTL AAZKR ABCUV ABDQB ABFLS ABOCM ACGFS ACPOU ACXQS ADACO ADBBV ADXAS ADZMN AENEX AEUQT AFBPY AFFNX AJYGW ALMA_UNASSIGNED_HOLDINGS ALUQN BFHJK DCZOG DRJOP DU5 EBS F5P G8K GJ H13 KQ8 LATKE LOXES LUTES LYRES MEWTI MRJOP MSJOP MXJOP O9- OK1 P2P P2W RHF RHI ROL RS9 TUL TWZ WIH WIJ WIK WOHZO X7M ZXP ZZTAW --- .55 .GJ 0R~ 18M 1OB 33P 6PF AAHHS AANLZ ABJNI ABLJU ABQWH ACCFJ ACCZN ACGFO ACGOF ADBTR ADKYN AEEZP AEIGN AEQDE AEUYR AFFPM AHBTC AITYG AIURR AIWBW AJBDE AMYDB C45 EJD HDBZQ HGLYW LEEKS N4W OVD SAMSI SUPJJ TEORI USG WXSBR ZGI ZVN 68V AAUGY IQODW CGR CUY CVF ECM EIF NPM AAMNL AAYXX ABDPE CITATION 7X8 |
ID | FETCH-LOGICAL-c4745-64907b015d32dd3a7d8fdba084d17964312e6d83b19038167a2ff2d68f9a44023 |
IEDL.DBID | 33P |
ISSN | 0278-4297 |
IngestDate | Thu Oct 24 22:56:34 EDT 2024 Thu Nov 21 22:22:08 EST 2024 Sat Sep 28 08:37:01 EDT 2024 Sun Oct 22 16:09:32 EDT 2023 Sat Aug 24 00:58:52 EDT 2024 Tue Nov 10 19:47:47 EST 2020 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 4 |
Keywords | Human Heart Doppler ultrasound study Measurement Angiography Price Analysis Aortic arch Echography Child Congenital disease |
Language | English |
License | CC BY 4.0 |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c4745-64907b015d32dd3a7d8fdba084d17964312e6d83b19038167a2ff2d68f9a44023 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
PMID | 11316315 |
PQID | 77074131 |
PQPubID | 23479 |
PageCount | 6 |
ParticipantIDs | proquest_miscellaneous_77074131 crossref_primary_10_7863_jum_2001_20_4_365 pubmed_primary_11316315 pascalfrancis_primary_928938 wiley_primary_10_7863_jum_2001_20_4_365_JUM2001204365 highwire_smallpub1_www20_4_365 |
ProviderPackageCode | RHF RHI |
PublicationCentury | 2000 |
PublicationDate | Apr 2001 |
PublicationDateYYYYMMDD | 2001-04-01 |
PublicationDate_xml | – month: 04 year: 2001 text: Apr 2001 |
PublicationDecade | 2000 |
PublicationPlace | Laurel, MD |
PublicationPlace_xml | – name: Laurel, MD – name: England |
PublicationTitle | Journal of ultrasound in medicine |
PublicationTitleAlternate | J Ultrasound Med |
PublicationYear | 2001 |
Publisher | Am inst Ulrrasound Med American Institute of Ultrasound in Medicine |
Publisher_xml | – name: Am inst Ulrrasound Med – name: American Institute of Ultrasound in Medicine |
SSID | ssj0020174 |
Score | 1.635781 |
Snippet | Noninvasive Doppler cardiac output measurements are clinical standards in adults and children. Presently, these standard Doppler methods generally require... |
SourceID | proquest crossref pubmed pascalfrancis wiley highwire |
SourceType | Aggregation Database Index Database Publisher |
StartPage | 365 |
SubjectTerms | Adolescent Biological and medical sciences Cardiac Catheterization Cardiac Output Cardiology. Vascular system Child Child, Preschool Congenital heart diseases. Malformations of the aorta, pulmonary vessels and vena cava Echocardiography, Doppler, Pulsed - methods Heart Heart Defects, Congenital - diagnostic imaging Heart Defects, Congenital - physiopathology Heart Function Tests - methods Humans Infant Infant, Newborn Linear Models Medical sciences Oxygen - blood Oxygen Consumption |
Title | Cardiac output measurements in congenital heart disease: validation of a simple, portable Doppler method |
URI | http://www.jultrasoundmed.org/cgi/content/abstract/20/4/365 https://onlinelibrary.wiley.com/doi/abs/10.7863%2Fjum.2001.20.4.365 https://www.ncbi.nlm.nih.gov/pubmed/11316315 https://search.proquest.com/docview/77074131 |
Volume | 20 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1La9wwEBZpIKWXtklf26apDjmVOo0etrS9hU1CCKQUmkBvQlpJdMvGDvGa_fudkexdlhQKpReDjT3I85Dm02hmCDlkOoYAC3mhNCsLWYqysMqxgtuowlRybjlmI198V19_6NMzLJMzGXJhcn2I1YYbWkaar9HArUtdSJSusNjAry4lkiPGO5JHosJEc0ALKY1DfFuBruO-EjMHtARzr8qRTaTx-QGFzbVpqBeMxyVtCxyLudXFn3zRTdc2rU3nz_7LXz0nT3vXlJ5kXdolW6HeI4-v-uD7HtlJp0Wn7Qvyc5L0akqbbnHXLejteqOxpbOaAsYGvcR2JBQbZi9oHwb6QkGvZ7mLE20itbSdYXXiTzShADcP9LQBtzjc09zZ-iW5OT-7nlwUfcuGYiqVLItKAth24GJ4wb0XVnkdvbPHWnqGSa-C8VB5LRz4IRiyVJbHyH2l49hKgLLiFdmumzq8IdSzsWPRVUBKyeC0HgcthS-l4AFAXBiRj4OwzF2uzGEA0SAfDXAR-2syuBhpgIsjcjCI07S3dj4HsTGzXC7XL-xvCHlFcgyIVOgR-TDI3ID9YVDF1qHpWqMUOmWCjcjrrArrwcDTSjAgXSaJ_32U5vLmiqd0Zgl3b__xu3fkST4oh8eL9sn24r4L78mj1ncHyTR-A4D3C-I |
link.rule.ids | 315,782,786,1408,27933,27934,46064,46488 |
linkProvider | Wiley-Blackwell |
linkToHtml | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV3db9MwED-xIRgvfAwGhbH5gSdExvyR2OUNrZsKrBMSm8Sb5dSOKOqSaWnUf587J2lVgYSEeImUKDk592Hfz-e7A3jDTRECLuSJNjxNVCrTxOmcJ8IVOkyVEE5QNvL4m774bkanVCZn1OfCtPUhVhtuZBlxviYDpw1psnJtMqo28LOJmeQE8o7UkczSLbirMlRISuSQX1ew67irxSwQL-Hsq9vYJhF5_xuJzdWprxhMByZdjTwr2mYXf_JGN53buDqdPfo___UYHnbeKfvYqtMTuBPKXbg_6eLvu3AvHhid1k_hx0lUrSmrmsVNs2DX673Gms1KhjAbVZM6kjDqmb1gXSToA0PVnrWNnFhVMMfqGRUofsciEMjngY0q9IzDLWubWz-Dq7PTy5Nx0nVtSKZKqzTJFOLtHL0ML4X30mlvCp-7Y6M8p7xXyUXIvJE5uiIUtdROFIXwmSmGTiGalXuwXVZleAHM82HOizxDUlqF3JhhMEr6VEkREMeFAbztpWVv2uIcFkEN8dEiF6nFJseLVRa5OICDXp62vnbzOcqN2-VyuX5hf0PKK5JDBKXSDOCwF7pFE6S4iitD1dRWa_LLJB_A81YX1oPBp5nkSDqNIv_7KO3nq4mIGc0K717-43eHsDO-nJzb808XX17Bg_bcHJ022oftxW0TXsNW7ZuDaCe_AHCNEAo |
linkToPdf | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1Za9wwEB6alIa-9EivbdNED30qdRIdtrR9K7tZ0iMh0Ab6JuSVRLds7CVes3-_Mz52WVoolL4YbOxBnkOaT6OZAXjDTQwBF_JEG54mKpVp4nTOE-GiDlMlhBOUjXz-VV9-N-MzKpMz6nNh2voQ6w03soxmviYDX_hIRq5NRsUGftZNIjlhvGN1LLN0B-4qdMepgL6UV2vUddqVYhYIl3Dy1W1ok4ic_EZie3HqCwbTeUlXIcti2-viT87otm_bLE6Th__ltx7Bg843ZR9aZXoMd0KxD3sXXfR9H-41x0Wn1RP4MWoUa8rKermol-xms9NYsVnBEGSjYlI_EkYds5esiwO9Z6jYs7aNEysjc6yaUXnid6yBAfk8sHGJfnG4ZW1r66dwPTn7NjpPup4NyVRplSaZQrSdo4_hpfBeOu1N9Lk7NcpzynqVXITMG5mjI0IxS-1EjMJnJg6dQiwrn8FuURbhBTDPhzmPeYaktAq5McNglPSpkiIgigsDeNsLyy7a0hwWIQ3x0SIXqcEmx4tVFrk4gMNenLa6cfM5io3b1Wq1eeFgS8hrkkOEpNIM4KiXuUUDpKiKK0JZV1Zr8sokH8DzVhU2g8GnmeRIOm0k_vdR2k_XF6LJZ1Z49_IfvzuCvavxxH75ePn5FdxvD83RUaMD2F3e1uE17FS-Pmys5BcJvQ6w |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Cardiac+output+measurements+in+congenital+heart+disease%3A+validation+of+a+simple%2C+portable+Doppler+method&rft.jtitle=Journal+of+ultrasound+in+medicine&rft.au=Gentles%2C+T+L&rft.au=Neutze%2C+J+M&rft.au=Caulder%2C+A+L&rft.au=Greene%2C+E+R&rft.date=2001-04-01&rft.pub=American+Institute+of+Ultrasound+in+Medicine&rft.issn=0278-4297&rft.eissn=1550-9613&rft.volume=20&rft.issue=4&rft.spage=365&rft.epage=370&rft_id=info:doi/10.7863%2Fjum.2001.20.4.365&rft.externalDBID=10.7863%252Fjum.2001.20.4.365&rft.externalDocID=JUM2001204365 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0278-4297&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0278-4297&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0278-4297&client=summon |