Evaluation of a novel MRI-safe needle guidance toolkit for streamlined arthrography procedures

Currently, Magnetic Resonance arthrography procedures require two rooms and two imaging modalities: fluoroscopically guided needle insertion in a fluoroscopy suite, followed by diagnostic MRI in a separate MRI suite. The use of fluoroscopy for needle placement exposes patients to ionizing radiation,...

Full description

Saved in:
Bibliographic Details
Published in:Scientific reports Vol. 13; no. 1; p. 17610
Main Authors: Monfaredi, Reza, Yarmolenko, Pavel, Lee, Eung-Joo, Cleary, Kevin, Sharma, Karun
Format: Journal Article
Language:English
Published: London Nature Publishing Group UK 17-10-2023
Nature Publishing Group
Nature Portfolio
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Currently, Magnetic Resonance arthrography procedures require two rooms and two imaging modalities: fluoroscopically guided needle insertion in a fluoroscopy suite, followed by diagnostic MRI in a separate MRI suite. The use of fluoroscopy for needle placement exposes patients to ionizing radiation, which is an important concern, especially in pediatrics. The need for two different rooms and coordinating times for these rooms complicates hospital resource scheduling and logistics. In addition, the added delays could expose younger children to additional risks associated with the use of general anesthesia. To address these issues, we propose a new technique to streamline the arthrography procedure. Our proposed technology aims to eliminate exposure to ionizing radiation and to streamline arthrography procedures that are conducted solely under MRI. This toolkit consists of a 3D slicer-based user interface, a spatially unique silicone grid template, and a hand-held needle guidance device. Together, these tools are intended to simplify and shorten the procedure while maintaining accuracy and precision comparable to the current gold standard procedure. In our cadaver study, we evaluated the feasibility and accuracy of our novel MRI-safe Needle Guidance Toolkit for MRI arthrography procedures, achieving an average targeting accuracy of 3.2 ± 1.0 mm. The results presented in this study showed the feasibility and promise of our novel MRI-safe needle guidance toolkit for arthrography procedures.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2045-2322
2045-2322
DOI:10.1038/s41598-023-45063-w