Evaluation of a Lyophilized CRISPR-Cas12 Assay for a Sensitive, Specific, and Rapid Detection of SARS-CoV-2

We evaluated a lyophilized CRISPR-Cas12 assay for SARS-CoV-2 detection (Lyo-CRISPR SARS-CoV-2 kit) based on reverse transcription, isothermal amplification, and CRISPR-Cas12 reaction. From a total of 210 RNA samples extracted from nasopharyngeal swabs using spin columns, the Lyo-CRISPR SARS-CoV-2 ki...

Full description

Saved in:
Bibliographic Details
Published in:Viruses Vol. 13; no. 3; p. 420
Main Authors: Curti, Lucía Ana, Primost, Ivana, Valla, Sofia, Ibañez Alegre, Daiana, Olguin Perglione, Cecilia, Repizo, Guillermo Daniel, Lara, Julia, Parcerisa, Ivana, Palacios, Antonela, Llases, María Eugenia, Rinflerch, Adriana, Barrios, Melanie, Pereyra Bonnet, Federico, Gimenez, Carla Alejandra, Marcone, Débora Natalia
Format: Journal Article
Language:English
Published: Switzerland MDPI AG 05-03-2021
MDPI
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We evaluated a lyophilized CRISPR-Cas12 assay for SARS-CoV-2 detection (Lyo-CRISPR SARS-CoV-2 kit) based on reverse transcription, isothermal amplification, and CRISPR-Cas12 reaction. From a total of 210 RNA samples extracted from nasopharyngeal swabs using spin columns, the Lyo-CRISPR SARS-CoV-2 kit detected 105/105 (100%; 95% confidence interval (CI): 96.55-100) positive samples and 104/105 (99.05%; 95% CI: 94.81-99.97) negative samples that were previously tested using commercial RT-qPCR. The estimated overall Kappa index was 0.991, reflecting an almost perfect concordance level between the two diagnostic tests. An initial validation test was also performed on 30 nasopharyngeal samples collected in lysis buffer, in which the Lyo-CRISPR SARS-CoV-2 kit detected 20/21 (95.24%; 95% CI: 76.18-99.88) positive samples and 9/9 (100%; 95% CI: 66.37-100) negative samples. The estimated Kappa index was 0.923, indicating a strong concordance between the test procedures. The Lyo-CRISPR SARS-CoV-2 kit was suitable for detecting a wide range of RT-qPCR-positive samples (cycle threshold range: 11.45-36.90) and dilutions of heat-inactivated virus (range: 2.5-100 copies/µL); no cross-reaction was observed with the other respiratory pathogens tested. We demonstrated that the performance of the Lyo-CRISPR SARS-CoV-2 kit was similar to that of commercial RT-qPCR, as the former was highly sensitive and specific, timesaving (1.5 h), inexpensive, and did not require sophisticated equipment. The use of this kit would reduce the time taken for diagnosis and facilitate molecular diagnosis in low-resource laboratories.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Undefined-1
ObjectType-Feature-3
content type line 23
These first authors contributed equally to this article.
These authors were co-principal investigators.
ISSN:1999-4915
1999-4915
DOI:10.3390/v13030420