Mechanical stability of the femoral fixation for single- and double-bundle ACL reconstruction in an in vitro experimental model
Anterior cruciate ligament ACL reconstruction using the double‐bundle (DB) technique is gaining popularity. A possible weak link in the DB technique could be that two tendon grafts of smaller diameters are used. The purpose of this study was to test different femoral fixation methods and graft diame...
Saved in:
Published in: | Scandinavian journal of medicine & science in sports Vol. 23; no. 3; pp. 263 - 270 |
---|---|
Main Authors: | , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Denmark
Blackwell Publishing Ltd
01-06-2013
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Anterior cruciate ligament ACL reconstruction using the double‐bundle (DB) technique is gaining popularity. A possible weak link in the DB technique could be that two tendon grafts of smaller diameters are used. The purpose of this study was to test different femoral fixation methods and graft diameters representing single‐bundle (SB) and DB ACL reconstructions and compare their biomechanical properties. We hypothesized that SB 6‐mm graft constructs had inferior biomechanical properties than SB 9‐mm grafts or DB 2 × 6‐mm grafts. Furthermore, we hypothesized that interference (IF) screw fixation would demonstrate less elongation and a higher stiffness than Endobutton (Smith & Nephew®, Inc., Andover, Massachusetts, USA) fixation (EBF). We performed an in vitro study using porcine knees and extensor tendons. The mechanical test consisted of a cyclic test followed by a load‐to‐failure test. We found that 6‐mm graft constructs had an ultimate failure load that was up to 40% less than both the 9‐mm and 2 × 6‐mm graft constructs, despite the fixation method (P‐values ≥ 0.004). Comparing fixation methods, EBF was superior to IF concerning maximum load to failure (P < 0.001); IF resulted in a higher stiffness of the femur/graft complex than the EBF (P < 0.001) but no significant difference in elongation between fixation methods. Since the two graft strands are subjected to different loads in different knee flexion angles, the reduced strength of the individual graft strands in DB ACL reconstruction could be a concern. |
---|---|
Bibliography: | Orthoconcept Inc. Danish Rheumatoid association (Gigtforeningen) istex:E0EE8BF868EB8A91CAA4F05D98143DDA5F156533 ArticleID:SMS1402 ark:/67375/WNG-GJNFDJCX-P ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 ObjectType-Article-2 ObjectType-Feature-1 |
ISSN: | 0905-7188 1600-0838 |
DOI: | 10.1111/j.1600-0838.2011.01402.x |