Abstract Many surgical methods and hemostatic agents can be used to achieve and maintain hemostasis in surgical fields. Numerous clinical situations exist where current treatment modalities are neither effective nor practical. Assessment of new hemostats primarily targets efficacy. However, the bioc...

Full description

Saved in:
Bibliographic Details
Published in:Biomaterials Vol. 31; no. 13; pp. 3649 - 3656
Main Authors: Muench, Tim R, Kong, Wei, Harmon, Alex M
Format: Journal Article
Language:English
Published: Netherlands Elsevier Ltd 01-05-2010
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Many surgical methods and hemostatic agents can be used to achieve and maintain hemostasis in surgical fields. Numerous clinical situations exist where current treatment modalities are neither effective nor practical. Assessment of new hemostats primarily targets efficacy. However, the biocompatibility and healing properties associated with hemostats are crucial for regulatory approval and product acceptance. Standard biocompatibility and healing studies may not be appropriate for hemostats containing active biologics. Liver defects in NTac:NIH- Whn (athymic) and Sprague Dawley® ™ Outbred (immunocompetent) rats were treated with Fibrin Pad (absorbable matrix containing human-derived biologics) or the matrix only. Defects were evaluated at 14 and 28 days post-implantation. As expected, Fibrin Pad in immunocompetent rats induced a cellular immune response. Unexpectedly, biologically significant decreases in healing, material absorption, and local fibrin degradation were also present. Evaluation of Fibrin Pad in immunocompetent animal models must consider potentially significant alterations in healing, material absorption, and local fibrin degradation, in addition to the expected immune response; none of which may be relevant when Fibrin Pad is used in the clinical setting. These considerations are essential when standard efficacy and biocompatibility studies assessing Fibrin Pad are submitted for regulatory consideration or utilized as pre-clinical translational studies.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0142-9612
1878-5905
DOI:10.1016/j.biomaterials.2010.01.070