Hemodynamic and clinical outcomes with the biocor valve in the aortic position: an 8-year experience

The aim of this study was to analyze the 8-year experience, survival, prosthetic complications, and hemodynamics of patients who received the Biocor valve, a new-generation tissue valve, in the aortic position. From May 1992 through May 2001, 257 consecutive patients (129 women and 128 men; mean age...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of thoracic and cardiovascular surgery Vol. 127; no. 6; pp. 1616 - 1623
Main Authors: Bottio, Tomaso, Rizzoli, Giulio, Thiene, Gaetano, Nesseris, Georgios, Casarotto, Dino, Gerosa, Gino
Format: Journal Article
Language:English
Published: Philadelphia, PA Mosby, Inc 01-06-2004
AATS/WTSA
Elsevier
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The aim of this study was to analyze the 8-year experience, survival, prosthetic complications, and hemodynamics of patients who received the Biocor valve, a new-generation tissue valve, in the aortic position. From May 1992 through May 2001, 257 consecutive patients (129 women and 128 men; mean age, 75 ± 6 years; age range, 45-91 years) received 258 aortic Biocor porcine prostheses. One female patient who received 2 Biocor valves in the aortic position during 2 consecutive operations was entered twice in the statistical analysis. Twelve (4.6%) patients had previous aortic valve operations. Preoperatively, 82 (32%) patients were in New York Heart Association functional class III or IV. Associated surgical procedures included coronary artery bypass grafting in 56 (21.7%) patients, aortic annular enlargement or aortoplasty in 20 (8%) patients, and others in 8 (3%) patients. Echocardiography was performed in the majority of long-term survivors (91.6%). Follow-up included 1215 patient-years and was 100% complete, with a median time of 5 patient-years (range, 0.4-10.5 years). There were 16 (6.2%) early deaths. According to a univariate analysis, New York Heart Association functional class III or IV, concomitant procedures, ejection fractions of less than 40%, and urgent operations were identified as significant perioperative risk factors. At follow-up, 75 patients died; 8-year actuarial Kaplan-Meier survival was 48% ± 5%. At 8 years, the actuarial freedom from valve-related death was 92% ± 2.6%, the freedom from thromboembolism was 93% ± 2%, the freedom from anticoagulant-related hemorrhage was 95% ± 2%, the freedom from endocarditis was 99% ± 0.6%, the freedom from paravalvular leak was 96% ± 1.5%, the freedom from all valve-related complications was 78% ± 4.5%, and the freedom from structural valve deterioration was 95% ± 3.7%. At 8 years, the actuarial freedom from structural valve deterioration was 89% ± 10% and 95.8% ± 4% in patients younger and older than 65 years, respectively. At 10 years, in patients older than 65 years, the actual freedom from structural valve deterioration was 97.9% ± 2.1%, and the freedom from reoperation was 97% ± 1.3%. New York Heart Association status was I or II in 90% of patients at the end of follow-up. The mean echocardiographic follow-up time was 4.6 ± 2 years. By using Doppler echocardiography, the peak and mean transprosthetic gradients were determined to be 30.8 ± 9.3 mm Hg and 16.6 ± 5.3 mm Hg, respectively. Mean mass/volume ratio and left ventricular end-diastolic volume were 1.37 ± 0.17 g/mL and 63.4 ± 22.6 mL/m 2, respectively. The majority of patients showed a persistent left ventricular hypertrophy. The Biocor is an effective bioprosthesis with a low incidence of valve-related complications comparable with that of other second-generation bioprostheses. This stented porcine prosthesis provides satisfactory results in terms of hemodynamics, valve durability, and freedom from reoperation.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0022-5223
1097-685X
DOI:10.1016/j.jtcvs.2003.10.041