Arthroscopic Meniscal Repair Using the BioStinger

Purpose: Biodegradable devices are available for all-inside meniscal repairs. One device, the BioStinger (Linvatec, Largo, FL), is made of molded poly-L-lactic acid. The purpose of this study was to evaluate the effectiveness of and any adverse events associated with meniscus repair using this devic...

Full description

Saved in:
Bibliographic Details
Published in:Arthroscopy Vol. 21; no. 6; pp. 744 - 750
Main Authors: Barber, F. Alan, Johnson, Donald H., Halbrecht, Jeffrey L.
Format: Journal Article
Language:English
Published: Philadelphia, PA Elsevier Inc 01-06-2005
Elsevier
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Purpose: Biodegradable devices are available for all-inside meniscal repairs. One device, the BioStinger (Linvatec, Largo, FL), is made of molded poly-L-lactic acid. The purpose of this study was to evaluate the effectiveness of and any adverse events associated with meniscus repair using this device. Type of Study Nonrandomized prospective cohort study. Methods: A prospective, consecutive, 3-center meniscal repair series using BioStingers (group 1), vertical inside-out sutures (group 2), or hybrid repairs combining BioStingers and sutures (group 3) was studied. Lysholm, Tegner, Cincinnati, and IKDC activity scores were obtained and clinical outcomes and adverse events documented. Results: There were 85 patients who underwent 89 meniscus repairs with an average 26.5 months of follow-up. There were 47 BioStinger repairs (group 1), 29 suture repairs (group 2), and 13 hybrid repairs (group 3). The tear length was statistically greater for the hybrid repair group ( P < .5). There were 73 repairs associated with anterior cruciate ligament reconstructions and 12 repeat arthroscopies were performed. Meniscal healing failed in 6 knees (4 in group 1, 0 in group 2, and 2 in group 3). The meniscal healing failed in 7% of those associated with anterior cruciate ligament reconstructions. Mean Tegner scores improved from 2.8 to 6.3, the final IKDC activity score was 3.2 out of 4, the mean Lysholm score improved from 51 to 88, and the mean Cincinnati score improved from 44 to 84. Two BioStinger repair cases had joint-line tenderness from device migration confirmed by magnetic resonance imaging. No tenting of the skin or articular cartilage scuffing was observed. Conclusions: The success rate for the 29 suture repairs was 100% and for the 47 BioStinger repairs was 91%. These preliminary results are consistent with other repair techniques. Level of Evidence: Level II, Therapeutic Prospective Cohort Study.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0749-8063
1526-3231
DOI:10.1016/j.arthro.2005.03.002