The impact of gestational age and fetal weight on the risk of failure of spinal anesthesia for cesarean delivery

Abstract Background There are limited data about spinal dosing for cesarean delivery in preterm parturients. We investigated the hypothesis that preterm gestation is associated with an increased incidence of inadequate spinal anesthesia for cesarean delivery compared with term gestation. Methods We...

Full description

Saved in:
Bibliographic Details
Published in:International journal of obstetric anesthesia Vol. 26; pp. 8 - 14
Main Authors: Adesope, O.A, Einhorn, L.M, Olufolabi, A.J, Cooter, M, Habib, A.S
Format: Journal Article
Language:English
Published: Netherlands Elsevier Ltd 01-05-2016
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Background There are limited data about spinal dosing for cesarean delivery in preterm parturients. We investigated the hypothesis that preterm gestation is associated with an increased incidence of inadequate spinal anesthesia for cesarean delivery compared with term gestation. Methods We searched our perioperative database for women who underwent cesarean delivery under spinal or combined spinal-epidural anesthesia with hyperbaric bupivacaine ⩾10.5 mg. The primary outcome was the incidence of inadequate surgical anesthesia needing conversion to general anesthesia or repetition or supplementation of the block. We divided patients into four categories: <28, 28 to <32, 32 to <37 and ⩾37 weeks of gestation. The chi-square test was used to compare failure rates and a multivariable regression analysis was performed to investigate potential confounders of the relationship between gestational age and failure. Results A total of 5015 patients (3387 term and 1628 preterm) were included. There were 278 failures (5.5%). The incidence of failure was higher in preterm versus term patients (6.4% vs. 5.1%, P =0.02). Failure rates were 10.8%, 7.7 %, 5.3 % and 5 % for <28, 28 to <32, 32 to <37 and ⩾37 weeks of gestation, respectively. In the multivariable model, low birth weight ( P <0.0001), gestational age ( P =0.03), ethnicity ( P =0.02) and use of combined spinal-epidural anesthesia ( P <0.0001) were significantly associated with failure. Conclusions At standard spinal doses of hyperbaric bupivacaine used in our practice (⩾10.5 mg), there were higher odds of inadequate surgical anesthesia in preterm parturients. When adjusting for potential confounders, low birth weight was the main factor associated with failure.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0959-289X
1532-3374
DOI:10.1016/j.ijoa.2016.01.007