Influence of antibiotic pellets on pore size and shear stress resistance of impacted native and thermodisinfected cancellous bone: An in vitro femoral impaction bone grafting model
Morphology and mechanic properties of impacted cancellous bone are affected by carrier substances which provide high local concentrations of antibiotics. Bone chips were taken from the femoral head of 6–7 months old piglets. One half was thermodisinfected and the other remained native. Ten specimens...
Saved in:
Published in: | Journal of orthopaedics Vol. 22; pp. 414 - 421 |
---|---|
Main Authors: | , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
India
Elsevier B.V
01-11-2020
Elsevier |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Morphology and mechanic properties of impacted cancellous bone are affected by carrier substances which provide high local concentrations of antibiotics.
Bone chips were taken from the femoral head of 6–7 months old piglets. One half was thermodisinfected and the other remained native. Ten specimens each were mixed with Herafill® antibiotic pellets and a control group of each 10 specimens respectively was examined. The cancellous bone was impacted according to Exeter technique and the implants were cemented. The distribution of the particles and the pores were defined with three dimensional computertomographic scan and shear force resistance was measured until failure.
Shear force resistance was not measured significantly less for thermodisinfected (2.7 Nm) compared with native bone (3.5 Nm) and addition of antibiotic pellets reduced shear force resistance in both groups since this was significant for the native group. The average pore volume of the native bone specimens appeared significant smaller compared to the thermodisinfected group (p = 0.011) and the pore volume showed a negative correlation with shear force resistance (p = 0.044). Pore volume around the pellets was found significantly increased and it appeared smaller for native bone. The number of pellets located next to the implant showed a negative correlation with shear force resistance (p = 0.034) and the negative correlation increased for pellets below the tip of the shaft model (p = 0.024).
Adding antibiotic pellets to native and thermodisinfected impacted cancellous bone increased pore volume since the area around the pellets showed increased porosity which correlated with reduced shear force resistance. Computertomographic three dimensional measurement of porosity might predict shear force resistance of impacted cancellous bone and improve impaction of bone grafting intraoperatively. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0972-978X 0972-978X |
DOI: | 10.1016/j.jor.2020.09.011 |