A rapid, sensitive and reliable diagnostic test for scrub typhus in China
Purpose: To evaluate the performances for detection of IgM and IgG antibodies to Orientia. tsutsugamushi (Ot) using a gold conjugate-based rapid diagnostic test (RDT). Materials and Methods: The RDT employing mixture recombinant 56-kDa proteins of O. tsutsugamushi and the mIFA assay was performed on...
Saved in:
Published in: | Indian journal of medical microbiology Vol. 29; no. 4; pp. 368 - 371 |
---|---|
Main Authors: | , , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
India
Elsevier B.V
01-10-2011
Elsevier Limited |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Purpose: To evaluate the performances for detection of IgM and IgG antibodies to Orientia. tsutsugamushi (Ot) using a gold conjugate-based rapid diagnostic test (RDT). Materials and Methods: The RDT employing mixture recombinant 56-kDa proteins of O. tsutsugamushi and the mIFA assay was performed on 33 patients from Fujian and Yunnan province respectively and 94 positive sera (36 from Hainan province and 58 from Jiangsu province) from convalescent stages of the patients with scrub typhus respectively and 82 negative sera from healthy farmers from Anhui province and Beijing City respectively in 2009. A comparison of the RDT and mIFA assay was performed by using the χ2 test and the P level of ≤0.05 was considered to be significant. Results: Among these 94 positive sera from convalescent stages of the illness and 82 sera from control farmers, the specificity of RDT was 100% for both IgM and IgG tests. In 33 cases with scrub typhus, 5 cases were positively detected earlier by RDT than by mIFA for the IgM test, and 2 cases were positive for the IgG test. The sensitivities of RDT were 93.9% and 90.9% for IgM and IgG, respectively. Considering IgM and IgG together, the sensitivity was 100%. The geometric mean titre (GMT) of IFA and the RDT assay in diluted sera from confirmed cases were 1:37 versus 1:113 respectively (P<0.001) for IgM test and 1:99 versus 1:279 respectively (P<0.016) for IgG. Conclusions: The RDT was more sensitive than the traditional IFA for the early diagnosis of scrub typhus and was particularly suitable for use in rural areas. |
---|---|
Bibliography: | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 |
ISSN: | 0255-0857 1998-3646 |
DOI: | 10.4103/0255-0857.90166 |