Positive End-expiratory Pressure and Distribution of Ventilation in Pneumoperitoneum Combined with Steep Trendelenburg Position

BACKGROUND:Pneumoperitoneum and a steep Trendelenburg position during robot-assisted laparoscopic prostatectomy have been demonstrated to promote a cranial shift of the diaphragm and the formation of atelectasis in the dorsal parts of the lungs. However, neither an impact of higher positive end-expi...

Full description

Saved in:
Bibliographic Details
Published in:Anesthesiology (Philadelphia) Vol. 132; no. 3; pp. 476 - 490
Main Authors: Shono, Atsuko, Katayama, Nozomi, Fujihara, Tatsuya, Böhm, Stephan H., Waldmann, Andreas D., Ugata, Kei, Nikai, Tetsuro, Saito, Yoji
Format: Journal Article
Language:English
Published: United States the American Society of Anesthesiologists, Inc. Wolters Kluwer Health, Inc 01-03-2020
Copyright by , the American Society of Anesthesiologists, Inc. Wolters Kluwer Health, Inc
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:BACKGROUND:Pneumoperitoneum and a steep Trendelenburg position during robot-assisted laparoscopic prostatectomy have been demonstrated to promote a cranial shift of the diaphragm and the formation of atelectasis in the dorsal parts of the lungs. However, neither an impact of higher positive end-expiratory pressure (PEEP) on preserving the ventilation in the dorsal region nor its physiologic effects have been fully examined. The authors hypothesized that PEEP of 15 cm H2O during robot-assisted laparoscopic prostatectomy might maintain ventilation in the dorsal parts and thus improve lung mechanics. METHODS:In this randomized controlled study, 48 patients undergoing robot-assisted laparoscopic prostatectomy were included in the analysis. Patients were assigned to the conventional PEEP (5 cm H2O) group or the high PEEP (15 cm H2O) group. Regional ventilation was monitored using electrical impedance tomography before and after the establishment of pneumoperitoneum and 20° Trendelenburg position during the surgery. The primary endpoint was the regional ventilation in the dorsal parts of the lungs while the secondary endpoints were lung mechanics and postoperative lung function. RESULTS:Compared to that in the conventional PEEP group, the fraction of regional ventilation in the most dorsal region was significantly higher in the high PEEP group during pneumoperitoneum and Trendelenburg position (mean values at 20 min after taking Trendelenburg positionconventional PEEP, 5.5 ± 3.9%; high PEEP, 9.9 ± 4.7%; difference, –4.5%; 95% CI, –7.4 to –1.6%; P = 0.004). Concurrently, lower driving pressure (conventional PEEP, 14.9 ± 2.5 cm H2O; high PEEP, 11.5 ± 2.8 cm H2O; P < 0.001), higher lung dynamic compliance, and better oxygenation were demonstrated in the high PEEP group. Postoperative lung function did not differ between the groups. CONCLUSIONS:Application of a PEEP of 15 cm H2O resulted in more homogeneous ventilation and favorable physiologic effects during robot-assisted laparoscopic prostatectomy but did not improve postoperative lung function.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-News-1
ObjectType-Feature-3
content type line 23
ISSN:0003-3022
1528-1175
DOI:10.1097/ALN.0000000000003062