Development of a Method for the Determination of Naphthalene and Phenanthrene in Workplace Air Using Diffusive Sampling and Thermal Desorption GC-MS Analysis

Diffusive sampling methods have been validated for the determination of naphthalene and phenanthrene in workplace air. The diffusive sampler tested was the Perkin Elmer ATD tube, and the analysis was performed with thermal desorption, gas chromatography, and mass spectrometric detection. The samplin...

Full description

Saved in:
Bibliographic Details
Published in:The Annals of occupational hygiene Vol. 55; no. 6; pp. 681 - 687
Main Authors: lindahl, Roger, Claesson, Anna-Sara, khan, Muhammad akhtar, levin, Jan-olof
Format: Journal Article
Language:English
Published: Oxford Oxford University Press 01-07-2011
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Diffusive sampling methods have been validated for the determination of naphthalene and phenanthrene in workplace air. The diffusive sampler tested was the Perkin Elmer ATD tube, and the analysis was performed with thermal desorption, gas chromatography, and mass spectrometric detection. The sampling methods were validated in controlled test atmospheres, mainly according to the protocol proposed in the European standard EN 838. For the determination of naphthalene, the diffusive sampling rate was 0.41 ml min−1 with a coefficient of variation (CV) of 19%. The mean sampling rate for phenanthrene was 0.49 ml min−1 with a CV of 21%. Field tests confirmed the naphthalene results but could not be used to confirm the phenanthrene results. The method is not recommended for phenanthrene sampling unless the method has been tested in the specific environment and the results confirm the laboratory tests.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0003-4878
1475-3162
1475-3162
DOI:10.1093/annhyg/mer039