Failures after revision hip arthroplasties with threaded cups and structural bone allografts. Loosening of 13/18 cases after 1-4 years
Uncemented threaded, smooth cup acetabular components and structural deep-frozen bone allografts harvested from femoral heads during arthroplasties were used for reconstruction of the acetabulum in 18 revision hip arthroplasties. Autogenous bone grafts were also used in every case. The mean follow-u...
Saved in:
Published in: | Acta orthopaedica Scandinavica Vol. 64; no. 4; p. 403 |
---|---|
Main Authors: | , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
England
1993
|
Subjects: | |
Online Access: | Get more information |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Uncemented threaded, smooth cup acetabular components and structural deep-frozen bone allografts harvested from femoral heads during arthroplasties were used for reconstruction of the acetabulum in 18 revision hip arthroplasties. Autogenous bone grafts were also used in every case. The mean follow-up time was 2.5 (1-4) years. Loosening of the prosthetic component occurred in 13 cases. In 8 cases revision of the acetabular component has already been performed, and 5 cases remain to be reoperated. The use of uncemented, threaded cups in combination with reconstruction of bone defects with structural allografts cannot be recommended in acetabular revisions. |
---|---|
ISSN: | 0001-6470 |
DOI: | 10.3109/17453679308993654 |