Glycaemic variability in paediatric patients with type 1 diabetes on continuous subcutaneous insulin infusion (CSII) or multiple daily injections (MDI): a cross-sectional cohort study

Summary Objective This cross‐sectional observational cohort study was designed to investigate i) whether glycaemic variability in paediatric patients with type 1 diabetes is lower in those using an insulin pump (CSII) compared with those using multiple daily insulin injections (MDI) and ii) whether...

Full description

Saved in:
Bibliographic Details
Published in:Clinical endocrinology (Oxford) Vol. 79; no. 5; pp. 641 - 647
Main Authors: Schreiver, C., Jacoby, U., Watzer, B., Thomas, A., Haffner, D., Fischer, D.-C.
Format: Journal Article
Language:English
Published: Oxford Blackwell Publishing Ltd 01-11-2013
Blackwell
Wiley Subscription Services, Inc
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract Summary Objective This cross‐sectional observational cohort study was designed to investigate i) whether glycaemic variability in paediatric patients with type 1 diabetes is lower in those using an insulin pump (CSII) compared with those using multiple daily insulin injections (MDI) and ii) whether urinary F2‐isoprostanes and/or urinary prostaglandin F2 excretion as surrogate marker of oxidative stress and cyclooxygenase activity are associated with glycaemic variability. Methods 48 paediatric patients with type 1 diabetes (22 using an insulin pump) underwent an ambulatory 3‐day continuous glucose monitoring. All patients continued with normal daily activities and collected urine for two consecutive 24 h periods. The glucose pentagon was used to calculate the glycaemic risk parameter. Results Insulin requirements, HDL‐cholesterol, the mean of glycaemic excursions (P < 0·01) and the standard deviation of mean glucose concentration (P < 0·05) were significantly lower in patients with CSII compared with those using MDI. By contrast, averaged HbA1c during the last twelve months as well as at the time of sensor insertion did not differ significantly between both groups. Summarizing characteristic parameter of acute and long‐term metabolic control into the glucose pentagon revealed a significantly lower glycaemic risk parameter in CSI patients compared with both, healthy subjects and patients using MDI (P < 0·05). Conclusions Paediatric patients with type 1 diabetes using an insulin pump presented with lower glycaemic variability and a concomitantly lower glycaemic risk parameter compared with those using MDII. Whether these findings translate into a lower risk of diabetes associated cardiovascular complications remains to be elucidated.
AbstractList Summary Objective This cross-sectional observational cohort study was designed to investigate i) whether glycaemic variability in paediatric patients with type 1 diabetes is lower in those using an insulin pump (CSII) compared with those using multiple daily insulin injections (MDI) and ii) whether urinary F2-isoprostanes and/or urinary prostaglandin F2 excretion as surrogate marker of oxidative stress and cyclooxygenase activity are associated with glycaemic variability. Methods 48 paediatric patients with type 1 diabetes (22 using an insulin pump) underwent an ambulatory 3-day continuous glucose monitoring. All patients continued with normal daily activities and collected urine for two consecutive 24 h periods. The glucose pentagon was used to calculate the glycaemic risk parameter. Results Insulin requirements, HDL-cholesterol, the mean of glycaemic excursions (P < 0·01) and the standard deviation of mean glucose concentration (P < 0·05) were significantly lower in patients with CSII compared with those using MDI. By contrast, averaged HbA1c during the last twelve months as well as at the time of sensor insertion did not differ significantly between both groups. Summarizing characteristic parameter of acute and long-term metabolic control into the glucose pentagon revealed a significantly lower glycaemic risk parameter in CSI patients compared with both, healthy subjects and patients using MDI (P < 0·05). Conclusions Paediatric patients with type 1 diabetes using an insulin pump presented with lower glycaemic variability and a concomitantly lower glycaemic risk parameter compared with those using MDII. Whether these findings translate into a lower risk of diabetes associated cardiovascular complications remains to be elucidated. [PUBLICATION ABSTRACT]
Summary Objective This cross‐sectional observational cohort study was designed to investigate i) whether glycaemic variability in paediatric patients with type 1 diabetes is lower in those using an insulin pump ( CSII ) compared with those using multiple daily insulin injections ( MDI ) and ii) whether urinary F 2 ‐isoprostanes and/or urinary prostaglandin F 2 excretion as surrogate marker of oxidative stress and cyclooxygenase activity are associated with glycaemic variability. Methods 48 paediatric patients with type 1 diabetes (22 using an insulin pump) underwent an ambulatory 3‐day continuous glucose monitoring. All patients continued with normal daily activities and collected urine for two consecutive 24 h periods. The glucose pentagon was used to calculate the glycaemic risk parameter. Results Insulin requirements, HDL ‐cholesterol, the mean of glycaemic excursions ( P  < 0·01) and the standard deviation of mean glucose concentration ( P  < 0·05) were significantly lower in patients with CSII compared with those using MDI . By contrast, averaged HbA 1c during the last twelve months as well as at the time of sensor insertion did not differ significantly between both groups. Summarizing characteristic parameter of acute and long‐term metabolic control into the glucose pentagon revealed a significantly lower glycaemic risk parameter in CSI patients compared with both, healthy subjects and patients using MDI ( P  < 0·05). Conclusions Paediatric patients with type 1 diabetes using an insulin pump presented with lower glycaemic variability and a concomitantly lower glycaemic risk parameter compared with those using MDII . Whether these findings translate into a lower risk of diabetes associated cardiovascular complications remains to be elucidated.
Summary Objective This cross‐sectional observational cohort study was designed to investigate i) whether glycaemic variability in paediatric patients with type 1 diabetes is lower in those using an insulin pump (CSII) compared with those using multiple daily insulin injections (MDI) and ii) whether urinary F2‐isoprostanes and/or urinary prostaglandin F2 excretion as surrogate marker of oxidative stress and cyclooxygenase activity are associated with glycaemic variability. Methods 48 paediatric patients with type 1 diabetes (22 using an insulin pump) underwent an ambulatory 3‐day continuous glucose monitoring. All patients continued with normal daily activities and collected urine for two consecutive 24 h periods. The glucose pentagon was used to calculate the glycaemic risk parameter. Results Insulin requirements, HDL‐cholesterol, the mean of glycaemic excursions (P < 0·01) and the standard deviation of mean glucose concentration (P < 0·05) were significantly lower in patients with CSII compared with those using MDI. By contrast, averaged HbA1c during the last twelve months as well as at the time of sensor insertion did not differ significantly between both groups. Summarizing characteristic parameter of acute and long‐term metabolic control into the glucose pentagon revealed a significantly lower glycaemic risk parameter in CSI patients compared with both, healthy subjects and patients using MDI (P < 0·05). Conclusions Paediatric patients with type 1 diabetes using an insulin pump presented with lower glycaemic variability and a concomitantly lower glycaemic risk parameter compared with those using MDII. Whether these findings translate into a lower risk of diabetes associated cardiovascular complications remains to be elucidated.
OBJECTIVEThis cross-sectional observational cohort study was designed to investigate i) whether glycaemic variability in paediatric patients with type 1 diabetes is lower in those using an insulin pump (CSII) compared with those using multiple daily insulin injections (MDI) and ii) whether urinary F2 -isoprostanes and/or urinary prostaglandin F2 excretion as surrogate marker of oxidative stress and cyclooxygenase activity are associated with glycaemic variability.METHODS48 paediatric patients with type 1 diabetes (22 using an insulin pump) underwent an ambulatory 3-day continuous glucose monitoring. All patients continued with normal daily activities and collected urine for two consecutive 24 h periods. The glucose pentagon was used to calculate the glycaemic risk parameter.RESULTSInsulin requirements, HDL-cholesterol, the mean of glycaemic excursions (P < 0·01) and the standard deviation of mean glucose concentration (P < 0·05) were significantly lower in patients with CSII compared with those using MDI. By contrast, averaged HbA1c during the last twelve months as well as at the time of sensor insertion did not differ significantly between both groups. Summarizing characteristic parameter of acute and long-term metabolic control into the glucose pentagon revealed a significantly lower glycaemic risk parameter in CSI patients compared with both, healthy subjects and patients using MDI (P < 0·05).CONCLUSIONSPaediatric patients with type 1 diabetes using an insulin pump presented with lower glycaemic variability and a concomitantly lower glycaemic risk parameter compared with those using MDII. Whether these findings translate into a lower risk of diabetes associated cardiovascular complications remains to be elucidated.
This cross-sectional observational cohort study was designed to investigate i) whether glycaemic variability in paediatric patients with type 1 diabetes is lower in those using an insulin pump (CSII) compared with those using multiple daily insulin injections (MDI) and ii) whether urinary F2 -isoprostanes and/or urinary prostaglandin F2 excretion as surrogate marker of oxidative stress and cyclooxygenase activity are associated with glycaemic variability. 48 paediatric patients with type 1 diabetes (22 using an insulin pump) underwent an ambulatory 3-day continuous glucose monitoring. All patients continued with normal daily activities and collected urine for two consecutive 24 h periods. The glucose pentagon was used to calculate the glycaemic risk parameter. Insulin requirements, HDL-cholesterol, the mean of glycaemic excursions (P < 0·01) and the standard deviation of mean glucose concentration (P < 0·05) were significantly lower in patients with CSII compared with those using MDI. By contrast, averaged HbA1c during the last twelve months as well as at the time of sensor insertion did not differ significantly between both groups. Summarizing characteristic parameter of acute and long-term metabolic control into the glucose pentagon revealed a significantly lower glycaemic risk parameter in CSI patients compared with both, healthy subjects and patients using MDI (P < 0·05). Paediatric patients with type 1 diabetes using an insulin pump presented with lower glycaemic variability and a concomitantly lower glycaemic risk parameter compared with those using MDII. Whether these findings translate into a lower risk of diabetes associated cardiovascular complications remains to be elucidated.
Author Thomas, A.
Haffner, D.
Watzer, B.
Schreiver, C.
Fischer, D.-C.
Jacoby, U.
Author_xml – sequence: 1
  givenname: C.
  surname: Schreiver
  fullname: Schreiver, C.
  organization: Department of Paediatrics, University Hospital Rostock, Hannover, Germany
– sequence: 2
  givenname: U.
  surname: Jacoby
  fullname: Jacoby, U.
  organization: Department of Paediatrics, University Hospital Rostock, Hannover, Germany
– sequence: 3
  givenname: B.
  surname: Watzer
  fullname: Watzer, B.
  organization: Department of Paediatrics, Philipps University Marburg, Hannover, Germany
– sequence: 4
  givenname: A.
  surname: Thomas
  fullname: Thomas, A.
  organization: Medtronic GmbH, Meerbusch, Germany
– sequence: 5
  givenname: D.
  surname: Haffner
  fullname: Haffner, D.
  organization: Department of Paediatrics, University Hospital Rostock, Hannover, Germany
– sequence: 6
  givenname: D.-C.
  surname: Fischer
  fullname: Fischer, D.-C.
  email: dagmar-christiane.fischer@med.uni-rostock.de
  organization: Department of Paediatrics, University Hospital Rostock, Hannover, Germany
BackLink http://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=27774835$$DView record in Pascal Francis
https://www.ncbi.nlm.nih.gov/pubmed/23134485$$D View this record in MEDLINE/PubMed
BookMark eNp1kctuEzEUhi1URNPCghdAlhBSspjW17mwQ6GESCGAuC0tj8ejOjiewfZQ5sl4PZxOWiQkvLHs853_9_F_Bk5c5zQATzG6wGldKu0uMEEVfQBmmOY8IyTnJ2CGKEIZynN2Cs5C2CGEeImKR-CUUEwZK_kM_F7ZUUm9Nwr-lN7I2lgTR2gc7KVujIw-VXoZjXYxwBsTr2Ecew0xTMVaRx1g56DqXDRu6IYAw1CrIUqnDwfjwmCTlnHtEEwC58tP6_UCdh7uBxtNbzVspLEHw51WMSEBzt-9Xi9eQgmV70LIwnQvbXK57nyEIQ7N-Bg8bKUN-slxPwdf3lx9Xr7NNu9X6-WrTaYYwTTTvGRSMs5og6Vu87pCMqeVlDz9TYsUaUtOmGoZrzRXpMjrvFGsrBQvS84Io-dgPun2vvsx6BDF3gSlrZ0mFJgxSkuGME7o83_QXTf49PBEcVLxAlWEJ2oxUbfTed2K3pu99KPASBzSFClNcZtmYp8dFYd6r5t78i6-BLw4AjIoaVsvnTLhL1cUBSvpgbucuBtj9fh_R7G82t5ZZ1OHCVH_uu-Q_rvIC1pw8W27Ehu8_cg_fEViSf8ABQ7Iog
CODEN CLECAP
CitedBy_id crossref_primary_10_1186_s40842_019_0081_z
crossref_primary_10_1089_dia_2013_0357
crossref_primary_10_1159_000511241
crossref_primary_10_1155_2013_791283
crossref_primary_10_1002_dmrr_3086
crossref_primary_10_1111_dom_13842
crossref_primary_10_3390_nu13124473
crossref_primary_10_1016_j_anpedi_2013_09_007
crossref_primary_10_1016_j_anpedi_2016_12_008
crossref_primary_10_1016_j_bspc_2024_106065
crossref_primary_10_3310_hta22420
crossref_primary_10_1038_s41598_017_18284_z
crossref_primary_10_1007_s13410_021_01025_4
crossref_primary_10_1111_dme_13963
crossref_primary_10_1111_dme_12950
crossref_primary_10_1016_j_anpede_2013_09_005
crossref_primary_10_3389_fendo_2021_608232
crossref_primary_10_1007_s00592_014_0619_6
crossref_primary_10_1038_s41598_019_52165_x
crossref_primary_10_3390_jcm8111797
crossref_primary_10_1007_s11428_017_0205_y
crossref_primary_10_1080_02713683_2024_2333770
crossref_primary_10_1155_2016_4385312
crossref_primary_10_1007_s13340_021_00513_6
crossref_primary_10_1016_j_anpede_2016_12_007
crossref_primary_10_3390_jcm10112445
Cites_doi 10.1089/dia.2008.0119
10.1210/jc.2008-1415
10.1002/(SICI)1096-9888(199712)32:12<1362::AID-JMS606>3.0.CO;2-N
10.1056/NEJMoa0805017
10.1055/s-2007-985157
10.2337/diacare.26.4.1079
10.1007/s001120170107
10.1089/dia.2005.7.253
10.1089/dia.2007.0291
10.1681/ASN.2008030287
10.1507/endocrj.K08E-330
10.1007/s00125-007-0842-6
10.1016/0378-4347(93)E0408-I
10.1089/dia.2008.0138
10.1002/dmrr.1195
10.1001/jama.295.14.1681
10.1089/dia.2008.0132
10.1542/peds.114.2.S2.555
10.1007/s00592-009-0132-5
10.1042/CS20050025
10.2337/dc10-0355
10.1111/j.1399-543X.2006.00145.x
10.1111/j.1464-5491.2007.02311.x
10.1159/000151592
10.2337/diabetes.54.6.1615
10.1007/s00125-008-0974-3
10.1161/CIRCULATIONAHA.104.529651
ContentType Journal Article
Copyright 2012 John Wiley & Sons Ltd
2014 INIST-CNRS
2012 John Wiley & Sons Ltd.
Copyright © 2013 John Wiley & Sons Ltd
Copyright_xml – notice: 2012 John Wiley & Sons Ltd
– notice: 2014 INIST-CNRS
– notice: 2012 John Wiley & Sons Ltd.
– notice: Copyright © 2013 John Wiley & Sons Ltd
DBID BSCLL
IQODW
CGR
CUY
CVF
ECM
EIF
NPM
AAYXX
CITATION
7QP
K9.
NAPCQ
7X8
DOI 10.1111/cen.12093
DatabaseName Istex
Pascal-Francis
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
CrossRef
Calcium & Calcified Tissue Abstracts
ProQuest Health & Medical Complete (Alumni)
Nursing & Allied Health Premium
MEDLINE - Academic
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
CrossRef
ProQuest Health & Medical Complete (Alumni)
Nursing & Allied Health Premium
Calcium & Calcified Tissue Abstracts
MEDLINE - Academic
DatabaseTitleList ProQuest Health & Medical Complete (Alumni)
CrossRef

MEDLINE - Academic
MEDLINE
Database_xml – sequence: 1
  dbid: ECM
  name: MEDLINE
  url: https://search.ebscohost.com/login.aspx?direct=true&db=cmedm&site=ehost-live
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1365-2265
EndPage 647
ExternalDocumentID 3317548201
10_1111_cen_12093
23134485
27774835
CEN12093
ark_67375_WNG_L1NQ5PV0_C
Genre article
Research Support, Non-U.S. Gov't
Journal Article
GrantInformation_xml – fundername: Medtronic, Meerbusch Germany
GroupedDBID ---
.3N
.55
.GA
.GJ
.Y3
05W
08P
0R~
10A
1OB
1OC
29B
31~
33P
36B
3O-
3SF
4.4
50Y
50Z
51W
51X
52M
52N
52O
52P
52R
52S
52T
52U
52V
52W
52X
53G
5GY
5HH
5LA
5RE
5VS
66C
6J9
702
7PT
8-0
8-1
8-3
8-4
8-5
8UM
930
A01
A03
AAESR
AAEVG
AAHHS
AAKAS
AANLZ
AAONW
AAQQT
AASGY
AAXRX
AAZKR
ABCQN
ABCUV
ABEML
ABJNI
ABPVW
ABQWH
ABXGK
ACAHQ
ACBWZ
ACCFJ
ACCZN
ACGFO
ACGFS
ACGOF
ACMXC
ACPOU
ACPRK
ACSCC
ACXBN
ACXQS
ADBBV
ADBTR
ADEOM
ADIZJ
ADKYN
ADMGS
ADOZA
ADXAS
ADZCM
ADZMN
ADZOD
AEEZP
AEGXH
AEIGN
AEIMD
AENEX
AEQDE
AEUQT
AEUYR
AFBPY
AFEBI
AFFNX
AFFPM
AFGKR
AFPWT
AFZJQ
AHBTC
AHEFC
AHMBA
AIACR
AIAGR
AITYG
AIURR
AIWBW
AJBDE
ALAGY
ALMA_UNASSIGNED_HOLDINGS
ALUQN
AMBMR
AMYDB
ASPBG
ATUGU
AVWKF
AZBYB
AZFZN
AZVAB
BAFTC
BDRZF
BFHJK
BHBCM
BMXJE
BROTX
BRXPI
BSCLL
BY8
C45
CAG
COF
CS3
D-6
D-7
D-E
D-F
DCZOG
DPXWK
DR2
DRFUL
DRMAN
DRSTM
DU5
DUUFO
EBS
EJD
EMOBN
ESX
EX3
F00
F01
F04
F5P
FEDTE
FUBAC
FZ0
G-S
G.N
GODZA
H.X
HF~
HGLYW
HVGLF
HZI
HZ~
IHE
IX1
J0M
J5H
K48
KBYEO
LATKE
LC2
LC3
LEEKS
LH4
LITHE
LOXES
LP6
LP7
LUTES
LW6
LYRES
MEWTI
MJL
MK4
MRFUL
MRMAN
MRSTM
MSFUL
MSMAN
MSSTM
MXFUL
MXMAN
MXSTM
N04
N05
N9A
NF~
O66
O9-
OIG
OVD
P2P
P2W
P2X
P2Z
P4B
P4D
PALCI
PQQKQ
Q.N
Q11
QB0
R.K
REN
RIWAO
RJQFR
ROL
RX1
SAMSI
SUPJJ
TEORI
UB1
V8K
W8V
W99
WBKPD
WHWMO
WIH
WIJ
WIK
WOHZO
WOW
WQJ
WRC
WUP
WVDHM
WXI
WXSBR
X7M
XG1
YOC
YUY
ZGI
ZXP
ZZTAW
~IA
~WT
08R
AAJUZ
AAPBV
AAVGM
ABCVL
ABFLS
ABHUG
ABPTK
ACXME
ADAWD
ADDAD
ADGIM
AFVGU
AGJLS
IPNFZ
IQODW
PQEST
UMP
ZA5
CGR
CUY
CVF
ECM
EIF
NPM
AAYXX
CITATION
7QP
K9.
NAPCQ
7X8
ID FETCH-LOGICAL-c4213-e584aa4543d1aef6b90a639aa5030f0c2f8524cf459e5c276b6dc489c58854243
IEDL.DBID 33P
ISSN 0300-0664
IngestDate Fri Aug 16 22:39:26 EDT 2024
Thu Oct 10 17:38:57 EDT 2024
Fri Aug 23 01:15:13 EDT 2024
Sat Sep 28 07:57:42 EDT 2024
Fri Nov 25 01:04:04 EST 2022
Sat Aug 24 00:53:29 EDT 2024
Wed Oct 30 09:56:43 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 5
Keywords Endocrinopathy
Human
Immunopathology
Multiple
Variability
Autoimmune disease
Injection
Daily
Type 1 diabetes
Insulin pump
Cohort study
Cross sectional study
Child
Endocrinology
Glycemia
Public health
Language English
License CC BY 4.0
2012 John Wiley & Sons Ltd.
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c4213-e584aa4543d1aef6b90a639aa5030f0c2f8524cf459e5c276b6dc489c58854243
Notes Medtronic, Meerbusch Germany
ark:/67375/WNG-L1NQ5PV0-C
ArticleID:CEN12093
istex:219FBA26F4B6FB74F968610CE68F9BA1EAB63172
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
PMID 23134485
PQID 1529570925
PQPubID 36523
PageCount 7
ParticipantIDs proquest_miscellaneous_1443384011
proquest_journals_1529570925
crossref_primary_10_1111_cen_12093
pubmed_primary_23134485
pascalfrancis_primary_27774835
wiley_primary_10_1111_cen_12093_CEN12093
istex_primary_ark_67375_WNG_L1NQ5PV0_C
PublicationCentury 2000
PublicationDate November 2013
PublicationDateYYYYMMDD 2013-11-01
PublicationDate_xml – month: 11
  year: 2013
  text: November 2013
PublicationDecade 2010
PublicationPlace Oxford
PublicationPlace_xml – name: Oxford
– name: England
PublicationTitle Clinical endocrinology (Oxford)
PublicationTitleAlternate Clin Endocrinol
PublicationYear 2013
Publisher Blackwell Publishing Ltd
Blackwell
Wiley Subscription Services, Inc
Publisher_xml – name: Blackwell Publishing Ltd
– name: Blackwell
– name: Wiley Subscription Services, Inc
References Monami, M., Lamanna, C., Marchionni, N. et al. (2010) Continuous subcutaneous insulin infusion versus multiple daily insulin injections in type 1 diabetes: a meta-analysis. Acta Diabetologica, 47, 77-81.
Schweer, H., Watzer, B., Seyberth, H.W. et al. (1997) Improved quantification of 8-epi-prostaglandin F2 alpha and F2-isoprostanes by gas chromatography/triple-stage quadrupole mass spectrometry: partial cyclooxygenase-dependent formation of 8-epi-prostaglandin F2 alpha in humans. Journal of Mass Spectrometry, 32, 1362-1370.
Clarke, W. & Kovatchev, B. (2009) Statistical tools to analyze continuous glucose monitor data. Diabetes Technol Ther, 11(Suppl 1), S45-54.
Monnier, L., Mas, E., Ginet, C. et al. (2006) Activation of oxidative stress by acute glucose fluctuations compared with sustained chronic hyperglycemia in patients with type 2 diabetes. JAMA, 295, 1681-1687.
Giannini, C., Mohn, A., Chiarelli, F. et al. (2011) Macrovascular angiopathy in children and adolescents with type 1 diabetes. Diabetes Metab Res Rev, 27, 436-460.
Tamborlane, W.V., Beck, R.W., Bode, B.W. et al. (2008) Continuous glucose monitoring and intensive treatment of type 1 diabetes. New England Journal of Medicine, 359, 1464-1476.
Kromeyer-Hauschild, K., Wabitsch, M., Kunze, D. et al. (2001) Percentiles of body mass index in children and adolescents evaluated from different regional German studies. Monatsschr Kinderh, 149, 807-818.
Jeitler, K., Horvath, K., Berghold, A. et al. (2008) Continuous subcutaneous insulin infusion versus multiple daily insulin injections in patients with diabetes mellitus: systematic review and meta-analysis. Diabetologia, 51, 941-951.
Schalkwijk, C.G. & Stehouwer, C.D. (2005) Vascular complications in diabetes mellitus: the role of endothelial dysfunction. Clin Sci (Lond), 109, 143-159.
Mastrototaro, J., Shin, J., Marcus, A. et al. (2008) The accuracy and efficacy of real-time continuous glucose monitoring sensor in patients with type 1 diabetes. Diabetes Technol Ther, 10, 385-390.
Brownlee, M. (2005) The pathobiology of diabetic complications: a unifying mechanism. Diabetes, 54, 1615-1625.
Karagianni, P., Sampanis, C., Katsoulis, C. et al. (2009) Continuous subcutaneous insulin infusion versus multiple daily injections. Hippokratia, 13, 93-96.
Schwartz, G.J., Muñoz, A., Schneider, M.F. et al. (2009) New equations to estimate GFR in children with CKD. Journal of the American Society of Nephrology, 20, 629-637.
Hanas, R. & Adolfsson, P. (2006) Insulin pumps in pediatric routine care improve long-term metabolic control without increasing the risk of hypoglycemia. Pediatric diabetes, 7, 25-31.
Jakisch, B.I., Wagner, V.M., Heidtmann, B. et al. (2008) Comparison of continuous subcutaneous insulin infusion (CSII) and multiple daily injections (MDI) in paediatric Type 1 diabetes: a multicentre matched-pair cohort analysis over 3 years. Diabetic Medicine, 25, 80-85.
Derosa, G., Maffioli, P., D'Angelo, A. et al. (2009) Effects of insulin therapy with continuous subcutaneous insulin infusion (CSII) in diabetic patients: comparison with multi-daily insulin injections therapy (MDI). Endocrine Journal, 56, 571-578.
Danne, T., Lange, K. & Kordonouri, O. (2008) Real-time glucose sensors in children and adolescents with type-1 diabetes. Hormone Research, 70, 193-202.
McDonnell, C.M., Donath, S.M., Vidmar, S.I. et al. (2005) A novel approach to continuous glucose analysis utilizing glycemic variation. Diabetes Technol Ther, 7, 253-263.
Schweer, H., Watzer, B. & Seyberth, H.W. (1994) Determination of seven prostanoids in 1 ml of urine by gas chromatography-negative ion chemical ionization triple stage quadrupole mass spectrometry. Journal of Chromatography, 652, 221-227.
Wentholt, I.M., Kulik, W., Michels, R.P. et al. (2008) Glucose fluctuations and activation of oxidative stress in patients with type 1 diabetes. Diabetologia, 51, 183-190.
Colette, C. & Monnier, L. (2007) Acute glucose fluctuations and chronic sustained hyperglycemia as risk factors for cardiovascular diseases in patients with type 2 diabetes. Hormone and Metabolic Research, 39, 683-686.
Weissberg-Benchell, J., Antisdel-Lomaglio, J. & Seshadri, R. (2003) Insulin pump therapy: a meta-analysis. Diabetes Care, 26, 1079-1087.
Lepore, G., Corsi, A., Dodesini, A.R. et al. (2010) Continuous subcutaneous insulin infusion is better than multiple daily insulin injections in reducing glucose variability only in type 1 diabetes with good metabolic control. Diabetes Care, 33, e81.
Rodbard, D. (2009) Interpretation of continuous glucose monitoring data: glycemic variability and quality of glycemic control. Diabetes Technol Ther, 11(Suppl 1), S55-67.
Thomas, A., Schonauer, M., Achermann, F. et al. (2009) The "glucose pentagon": assessing glycemic control of patients with diabetes mellitus by a model integrating different parameters from glucose profiles. Diabetes Technol Ther, 11, 399-409.
Libby, P., Nathan, D.M., Abraham, K. et al. (2005) Report of the National Heart, Lung, and Blood Institute-National Institute of Diabetes and Digestive and Kidney Diseases Working Group on Cardiovascular Complications of Type 1 Diabetes Mellitus. Circulation, 111, 3489-3493.
Fatourechi, M.M., Kudva, Y.C., Murad, M.H. et al. (2009) Clinical review: Hypoglycemia with intensive insulin therapy: a systematic review and meta-analyses of randomized trials of continuous subcutaneous insulin infusion versus multiple daily injections. Journal of Clinical Endocrinology and Metabolism, 94, 729-740.
2007; 39
2009; 56
1994; 652
2009; 11
2010; 33
2009; 13
2010; 47
2009; 20
2005; 111
1997; 32
2009; 94
2006; 7
2008; 25
2006; 295
2005; 109
2005; 7
2003; 26
2005; 54
2008; 359
2008; 10
2011; 27
2008; 51
2008; 70
2001; 149
Karagianni P. (e_1_2_9_22_1) 2009; 13
e_1_2_9_11_1
e_1_2_9_10_1
e_1_2_9_13_1
e_1_2_9_12_1
e_1_2_9_15_1
e_1_2_9_14_1
e_1_2_9_17_1
e_1_2_9_16_1
e_1_2_9_19_1
e_1_2_9_18_1
e_1_2_9_20_1
e_1_2_9_21_1
e_1_2_9_24_1
e_1_2_9_23_1
e_1_2_9_8_1
e_1_2_9_7_1
e_1_2_9_6_1
e_1_2_9_5_1
e_1_2_9_4_1
e_1_2_9_3_1
e_1_2_9_2_1
e_1_2_9_9_1
e_1_2_9_26_1
e_1_2_9_25_1
e_1_2_9_28_1
e_1_2_9_27_1
e_1_2_9_29_1
References_xml – volume: 51
  start-page: 941
  year: 2008
  end-page: 951
  article-title: Continuous subcutaneous insulin infusion versus multiple daily insulin injections in patients with diabetes mellitus: systematic review and meta‐analysis
  publication-title: Diabetologia
– volume: 10
  start-page: 385
  year: 2008
  end-page: 390
  article-title: The accuracy and efficacy of real‐time continuous glucose monitoring sensor in patients with type 1 diabetes
  publication-title: Diabetes Technol Ther
– volume: 56
  start-page: 571
  year: 2009
  end-page: 578
  article-title: Effects of insulin therapy with continuous subcutaneous insulin infusion (CSII) in diabetic patients: comparison with multi‐daily insulin injections therapy (MDI)
  publication-title: Endocrine Journal
– volume: 109
  start-page: 143
  year: 2005
  end-page: 159
  article-title: Vascular complications in diabetes mellitus: the role of endothelial dysfunction
  publication-title: Clin Sci (Lond)
– volume: 13
  start-page: 93
  year: 2009
  end-page: 96
  article-title: Continuous subcutaneous insulin infusion versus multiple daily injections
  publication-title: Hippokratia
– volume: 359
  start-page: 1464
  year: 2008
  end-page: 1476
  article-title: Continuous glucose monitoring and intensive treatment of type 1 diabetes
  publication-title: New England Journal of Medicine
– volume: 33
  start-page: e81
  year: 2010
  article-title: Continuous subcutaneous insulin infusion is better than multiple daily insulin injections in reducing glucose variability only in type 1 diabetes with good metabolic control
  publication-title: Diabetes Care
– volume: 149
  start-page: 807
  year: 2001
  end-page: 818
  article-title: Percentiles of body mass index in children and adolescents evaluated from different regional German studies
  publication-title: Monatsschr Kinderh
– volume: 26
  start-page: 1079
  year: 2003
  end-page: 1087
  article-title: Insulin pump therapy: a meta‐analysis
  publication-title: Diabetes Care
– volume: 94
  start-page: 729
  year: 2009
  end-page: 740
  article-title: Clinical review: Hypoglycemia with intensive insulin therapy: a systematic review and meta‐analyses of randomized trials of continuous subcutaneous insulin infusion versus multiple daily injections
  publication-title: Journal of Clinical Endocrinology and Metabolism
– volume: 11
  start-page: S55
  issue: Suppl 1
  year: 2009
  end-page: 67
  article-title: Interpretation of continuous glucose monitoring data: glycemic variability and quality of glycemic control
  publication-title: Diabetes Technol Ther
– volume: 54
  start-page: 1615
  year: 2005
  end-page: 1625
  article-title: The pathobiology of diabetic complications: a unifying mechanism
  publication-title: Diabetes
– volume: 20
  start-page: 629
  year: 2009
  end-page: 637
  article-title: New equations to estimate GFR in children with CKD
  publication-title: Journal of the American Society of Nephrology
– volume: 39
  start-page: 683
  year: 2007
  end-page: 686
  article-title: Acute glucose fluctuations and chronic sustained hyperglycemia as risk factors for cardiovascular diseases in patients with type 2 diabetes
  publication-title: Hormone and Metabolic Research
– volume: 7
  start-page: 25
  year: 2006
  end-page: 31
  article-title: Insulin pumps in pediatric routine care improve long‐term metabolic control without increasing the risk of hypoglycemia
  publication-title: Pediatric diabetes
– volume: 7
  start-page: 253
  year: 2005
  end-page: 263
  article-title: A novel approach to continuous glucose analysis utilizing glycemic variation
  publication-title: Diabetes Technol Ther
– volume: 652
  start-page: 221
  year: 1994
  end-page: 227
  article-title: Determination of seven prostanoids in 1 ml of urine by gas chromatography‐negative ion chemical ionization triple stage quadrupole mass spectrometry
  publication-title: Journal of Chromatography
– volume: 11
  start-page: S45
  issue: Suppl 1
  year: 2009
  end-page: 54
  article-title: Statistical tools to analyze continuous glucose monitor data
  publication-title: Diabetes Technol Ther
– volume: 25
  start-page: 80
  year: 2008
  end-page: 85
  article-title: Comparison of continuous subcutaneous insulin infusion (CSII) and multiple daily injections (MDI) in paediatric Type 1 diabetes: a multicentre matched‐pair cohort analysis over 3 years
  publication-title: Diabetic Medicine
– volume: 11
  start-page: 399
  year: 2009
  end-page: 409
  article-title: The “glucose pentagon”: assessing glycemic control of patients with diabetes mellitus by a model integrating different parameters from glucose profiles
  publication-title: Diabetes Technol Ther
– volume: 27
  start-page: 436
  year: 2011
  end-page: 460
  article-title: Macrovascular angiopathy in children and adolescents with type 1 diabetes
  publication-title: Diabetes Metab Res Rev
– volume: 111
  start-page: 3489
  year: 2005
  end-page: 3493
  article-title: Report of the National Heart, Lung, and Blood Institute‐National Institute of Diabetes and Digestive and Kidney Diseases Working Group on Cardiovascular Complications of Type 1 Diabetes Mellitus
  publication-title: Circulation
– volume: 70
  start-page: 193
  year: 2008
  end-page: 202
  article-title: Real‐time glucose sensors in children and adolescents with type‐1 diabetes
  publication-title: Hormone Research
– volume: 32
  start-page: 1362
  year: 1997
  end-page: 1370
  article-title: Improved quantification of 8‐epi‐prostaglandin F2 alpha and F2‐isoprostanes by gas chromatography/triple‐stage quadrupole mass spectrometry: partial cyclooxygenase‐dependent formation of 8‐epi‐prostaglandin F2 alpha in humans
  publication-title: Journal of Mass Spectrometry
– volume: 47
  start-page: 77
  year: 2010
  end-page: 81
  article-title: Continuous subcutaneous insulin infusion versus multiple daily insulin injections in type 1 diabetes: a meta‐analysis
  publication-title: Acta Diabetologica
– volume: 51
  start-page: 183
  year: 2008
  end-page: 190
  article-title: Glucose fluctuations and activation of oxidative stress in patients with type 1 diabetes
  publication-title: Diabetologia
– volume: 295
  start-page: 1681
  year: 2006
  end-page: 1687
  article-title: Activation of oxidative stress by acute glucose fluctuations compared with sustained chronic hyperglycemia in patients with type 2 diabetes
  publication-title: JAMA
– ident: e_1_2_9_16_1
  doi: 10.1089/dia.2008.0119
– ident: e_1_2_9_20_1
  doi: 10.1210/jc.2008-1415
– ident: e_1_2_9_7_1
  doi: 10.1002/(SICI)1096-9888(199712)32:12<1362::AID-JMS606>3.0.CO;2-N
– ident: e_1_2_9_9_1
  doi: 10.1056/NEJMoa0805017
– ident: e_1_2_9_6_1
  doi: 10.1055/s-2007-985157
– ident: e_1_2_9_24_1
  doi: 10.2337/diacare.26.4.1079
– ident: e_1_2_9_11_1
  doi: 10.1007/s001120170107
– ident: e_1_2_9_14_1
  doi: 10.1089/dia.2005.7.253
– ident: e_1_2_9_25_1
  doi: 10.1089/dia.2007.0291
– ident: e_1_2_9_10_1
  doi: 10.1681/ASN.2008030287
– ident: e_1_2_9_19_1
  doi: 10.1507/endocrj.K08E-330
– ident: e_1_2_9_15_1
  doi: 10.1007/s00125-007-0842-6
– ident: e_1_2_9_13_1
  doi: 10.1016/0378-4347(93)E0408-I
– ident: e_1_2_9_26_1
  doi: 10.1089/dia.2008.0138
– ident: e_1_2_9_3_1
  doi: 10.1002/dmrr.1195
– ident: e_1_2_9_29_1
  doi: 10.1001/jama.295.14.1681
– ident: e_1_2_9_27_1
  doi: 10.1089/dia.2008.0132
– ident: e_1_2_9_12_1
  doi: 10.1542/peds.114.2.S2.555
– ident: e_1_2_9_23_1
  doi: 10.1007/s00592-009-0132-5
– ident: e_1_2_9_4_1
  doi: 10.1042/CS20050025
– ident: e_1_2_9_28_1
  doi: 10.2337/dc10-0355
– ident: e_1_2_9_17_1
  doi: 10.1111/j.1399-543X.2006.00145.x
– ident: e_1_2_9_21_1
  doi: 10.1111/j.1464-5491.2007.02311.x
– ident: e_1_2_9_8_1
  doi: 10.1159/000151592
– ident: e_1_2_9_5_1
  doi: 10.2337/diabetes.54.6.1615
– volume: 13
  start-page: 93
  year: 2009
  ident: e_1_2_9_22_1
  article-title: Continuous subcutaneous insulin infusion versus multiple daily injections
  publication-title: Hippokratia
  contributor:
    fullname: Karagianni P.
– ident: e_1_2_9_18_1
  doi: 10.1007/s00125-008-0974-3
– ident: e_1_2_9_2_1
  doi: 10.1161/CIRCULATIONAHA.104.529651
SSID ssj0005807
Score 2.2954345
Snippet Summary Objective This cross‐sectional observational cohort study was designed to investigate i) whether glycaemic variability in paediatric patients with type...
This cross-sectional observational cohort study was designed to investigate i) whether glycaemic variability in paediatric patients with type 1 diabetes is...
Summary Objective This cross-sectional observational cohort study was designed to investigate i) whether glycaemic variability in paediatric patients with type...
OBJECTIVEThis cross-sectional observational cohort study was designed to investigate i) whether glycaemic variability in paediatric patients with type 1...
SourceID proquest
crossref
pubmed
pascalfrancis
wiley
istex
SourceType Aggregation Database
Index Database
Publisher
StartPage 641
SubjectTerms Adolescent
Biological and medical sciences
Blood Glucose - drug effects
Child
Cross-Sectional Studies
Diabetes Mellitus, Type 1 - blood
Diabetes Mellitus, Type 1 - drug therapy
Diabetes. Impaired glucose tolerance
Drug Administration Schedule
Endocrine pancreas. Apud cells (diseases)
Endocrinopathies
Etiopathogenesis. Screening. Investigations. Target tissue resistance
Female
Fundamental and applied biological sciences. Psychology
General aspects
Humans
Infusions, Subcutaneous
Injections
Insulin - administration & dosage
Insulin - therapeutic use
Insulin Infusion Systems
Male
Medical sciences
Vertebrates: endocrinology
Title Glycaemic variability in paediatric patients with type 1 diabetes on continuous subcutaneous insulin infusion (CSII) or multiple daily injections (MDI): a cross-sectional cohort study
URI https://api.istex.fr/ark:/67375/WNG-L1NQ5PV0-C/fulltext.pdf
https://onlinelibrary.wiley.com/doi/abs/10.1111%2Fcen.12093
https://www.ncbi.nlm.nih.gov/pubmed/23134485
https://www.proquest.com/docview/1529570925
https://search.proquest.com/docview/1443384011
Volume 79
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1Lb9QwELagSIgL70egVANCaHvYKo7tJIYT2m7bleiqqLxukeM40kKVrTYNojd-An-Hv8MvYcZ5lJVAQuKURI4T2TNjz4y_mWHsWUrbSGL1OC_Q0pGpsOM0NgptHm54qJ0xObmyD46T-cd0d0ppcl72sTBtfojB4UaS4ddrEnCT178JuXXVDgV-UqZPtBJ8-IY4uoB3dKHSgiKn41h2WYUIxTP0XNuLrtC0fiVspKlxesq2rsWfFM91PdZvRHs3_msIN9n1Tv-EVy3D3GKXXHWbXT3sTtjvsB_7J-fWEGIevqAZ3WbxPodFBaemr-oBXTLWGsiLC-TFBQ69FxeWFRAAflE1y6aGusltgxqoo4cO-Y7XsiE3HYwmx7PZNixX0CMboTCLE_rhJw8Sq2oYHe7Otl-AAT-LP799r9sWHAaV912dgc-Re5e925u-nRyMu_IOYysjLsYOdR9jpJKi4MaVca5Dg_qSMQqJVoY2KlMVSVtKpZ2yURLncWFlqq1KUyUjKe6xjWpZuQcMuE6c1dLmoc1lkiotpVNFXGhXFriClQF72hM6O22zeGS99YNEyDwRAvbcs8Dwhll9JthborIP8_3sNZ-_UUfvw2wSsK01Hhk6RAkq06jSBmyzZ5qsWxLqjNORahLqCJufDM0ozHRC01IB7TApBJrcnAfsfstsFx8XXKAtjb1Hnqf-PpBsMp37m4f__uojdi2iQh8-ynKTbZytGveYXa6LZsvL1S8NNiXd
link.rule.ids 315,782,786,1408,27935,27936,46066,46490
linkProvider Wiley-Blackwell
linkToHtml http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1Lb9QwELZoKwEX3o9AKQNCaHsIimM7iREXtN12V-yuiloet8hxHGmhylabBtEbP4G_w9_hl-BxHmUlkJA4JZHjRPbM2DPjb2YIeZbgNhJr6We5tXR4wrSfREpYm4cqGkijVIau7PFRPP-Y7I0wTc6rLhamyQ_RO9xQMtx6jQKODunfpFyb8gVGfrINssUjLrFwA2OHFwCPNliaYex0FPE2rxDiePqua7vRFk7sV0RHqspOUNFUtviT6rmuybqtaP_6_w3iBrnWqqDwuuGZm-SSKW-Ry7P2kP02-XFwcq4Vgubhi7Wkm0Te57Ao4VR1hT2gzcdaATpyAR25QKFz5MKyBMTAL8p6WVdQ1ZmurRJq8KEFv9trUaOnDgbDo8lkF5Yr6MCNkKvFCf7wk8OJlRUMZnuT3ZegwE3jz2_fq6bFDgMr_K7OwKXJvUPe7Y-Oh2O_rfDgax5S5hur_ijFBWc5VaaIMhkoqzIpJSzVikCHRSJCrgsupBE6jKMsyjVPpBZJInjI2V2yWS5Lc58AlbHRkuss0BmPEyE5NyKPcmmK3C5ihUeedpROT5tEHmlnAFkipI4IHnnueKB_Q60-I_ItFumH-UE6pfO34vB9kA49srPGJH2HMLb6tNVqPbLdcU3argpVSvFUNQ5kaJuf9M1WnvGQpqGCNcU4Y9bqptQj9xpuu_g4o8ya07b3wDHV3weSDkdzd_Pg3199TK6Mj2fTdDqZv3lIroZY98MFXW6TzbNVbR6RjSqvd5yQ_QJi1yn-
linkToPdf http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1Lb9QwELZoK1VceD8CpQwIoe0hKI7tPOCE9tGuaKNFBcotchxHWqiyq02D6I2f0L_Tv8MvweM8ykogIXFKIseJ7JmxZ8bfzBDyIsJtJFSxm-XG0uERU24USGFsHiqpF2spM3RlHxyHyedoNMY0OW-6WJgmP0TvcEPJsOs1CvgyL34TcqXLVxj4yTbIFkc1HOM32OwK39HGSjMMnQ4C3qYVQhhP33VtM9rCef2O4EhZmfkpmsIWf9I81xVZuxNNbv7XGG6RG60CCm8bjrlNrunyDtk-ao_Y75LL_dNzJREyD9-MHd2k8T6HeQlL2ZX1gDYbawXoxgV04wKFzo0LixIQAT8v60VdQVVnqjYqqMaHFvpurkWNfjoYDI-n0z1YrKCDNkIu56f4wy8WJVZWMDgaTfdegwQ7iz9_XFRNixkG1vddnYFNknuPfJyMPwwP3La-g6u4T5mrjfIjJRec5VTqIshiTxqFSUphiFZ4yi8i4XNVcBFrofwwyIJc8ShWIooE9zm7TzbLRakfEqBxqFXMVeapjIeRiDnXIg_yWBe5WcIKhzzvCJ0umzQeaWf-GCKklggOeWlZoH9Drr4i7i0U6Umynx7S5L2YffLSoUN213ik7-CHRps2Oq1DdjqmSds1oUopnqmGXuyb5md9s5FmPKJpqGAMMc6YsbkpdciDhtmuPs4oM8a06T2wPPX3gaTDcWJvHv37q0_J9mw0SQ-nybvH5LqPRT9sxOUO2Txb1foJ2ajyeteK2C_H8Cit
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Glycaemic+variability+in+paediatric+patients+with+type+1+diabetes+on+continuous+subcutaneous+insulin+infusion+%28CSII%29+or+multiple+daily+injections+%28MDI%29%3A+a+cross%E2%80%90sectional+cohort+study&rft.jtitle=Clinical+endocrinology+%28Oxford%29&rft.au=Schreiver%2C+C.&rft.au=Jacoby%2C+U.&rft.au=Watzer%2C+B.&rft.au=Thomas%2C+A.&rft.date=2013-11-01&rft.issn=0300-0664&rft.eissn=1365-2265&rft.volume=79&rft.issue=5&rft.spage=641&rft.epage=647&rft_id=info:doi/10.1111%2Fcen.12093&rft.externalDBID=10.1111%252Fcen.12093&rft.externalDocID=CEN12093
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0300-0664&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0300-0664&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0300-0664&client=summon