Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation
Signal properties of the first large-area, high resolution, active matrix, flat-panel imager are reported. The imager is based on an array of 1536×1920 pixels with a pixel-to-pixel pitch of 127 μm. Each pixel consists of a discrete amorphous silicon n-i-p photodiode coupled to an amorphous silicon t...
Saved in:
Published in: | Medical physics (Lancaster) Vol. 24; no. 1; pp. 51 - 70 |
---|---|
Main Authors: | , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
United States
American Association of Physicists in Medicine
01-01-1997
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Abstract | Signal properties of the first large-area, high resolution, active matrix, flat-panel imager are reported. The imager is based on an array of 1536×1920 pixels with a pixel-to-pixel pitch of 127 μm. Each pixel consists of a discrete amorphous silicon n-i-p photodiode coupled to an amorphous silicon thin-film transistor. The imager detects incident x rays indirectly by means of an intensifying screen placed over the array. External acquisition electronics send control signals to the array and process analog imaging signals from the pixels. Considerations for operation of the imager in both fluoroscopic and radiographic modes are detailed and empirical signal performance data are presented with an emphasis on exploring similarities and differences between the two modes. Measurements which characterize the performance of the imager were performed as a function of operational parameters in the absence or presence of illumination from a light-emitting diode or x rays. These measurements include characterization of the drift and magnitude of the pixel dark signal, the size of the pixel switching transient, the temporal behavior of pixel sampling and the implied maximum frame rate, the dependence of relative pixel efficiency and pixel response on photodiode reverse bias voltage and operational mode, the degree of linearity of pixel response, and the trapping and release of charge from metastable states in the photodiodes. In addition, x-ray sensitivity as a function of energy for a variety of phosphor screens for both fluoroscopic and radiographic operation is reported. Example images of a line-pair pattern and an anthropomorphic phantom in each mode are presented along with a radiographic image of a human hand. General and specific improvements in imager design are described and anticipated developments are discussed. This represents the first systematic investigation of the operation and properties in both radiographic and fluoroscopic modes of an imager incorporating such an array. |
---|---|
AbstractList | Signal properties of the first large-area, high resolution, active matrix, flat-panel imager are reported. The imager is based on an array of 1536 x 1920 pixels with a pixel-to-pixel pitch of 127 microns. Each pixel consists of a discrete amorphous silicon n-i-p photodiode coupled to an amorphous silicon thin-film transistor. The imager detects incident x rays indirectly by means of an intensifying screen placed over the array. External acquisition electronics send control signals to the array and process analog imaging signals from the pixels. Considerations for operation of the imager in both fluoroscopic and radiographic modes are detailed and empirical signal performance data are presented with an emphasis on exploring similarities and differences between the two modes. Measurements which characterize the performance of the imager were performed as a function of operational parameters in the absence or presence of illumination from a light-emitting diode or x rays. These measurements include characterization of the drift and magnitude of the pixel dark signal, the size of the pixel switching transient, the temporal behavior of pixel sampling and the implied maximum frame rate, the dependence of relative pixel efficiency and pixel response on photodiode reverse bias voltage and operational mode, the degree of linearity of pixel response, and the trapping and release of charge from metastable states in the photodiodes. In addition, X-ray sensitivity as a function of energy for a variety of phosphor screens for both fluoroscopic and radiographic operation is reported. Example images of a line-pair pattern and an anthropomorphic phantom in each mode are presented along with a radiographic image of a human hand. General and specific improvements in imager design are described and anticipated developments are discussed. This represents the first systematic investigation of the operation and properties in both radiographic and fluoroscopic modes of an imager incorporating such an array. Signal properties of the first large‐area, high resolution, active matrix, flat‐panel imager are reported. The imager is based on an array of 1536×1920 pixels with a pixel‐to‐pixel pitch of 127 μm. Each pixel consists of a discrete amorphous silicon n‐i‐p photodiode coupled to an amorphous silicon thin‐film transistor. The imager detects incident x rays indirectly by means of an intensifying screen placed over the array. External acquisition electronics send control signals to the array and process analog imaging signals from the pixels. Considerations for operation of the imager in both fluoroscopic and radiographic modes are detailed and empirical signal performance data are presented with an emphasis on exploring similarities and differences between the two modes. Measurements which characterize the performance of the imager were performed as a function of operational parameters in the absence or presence of illumination from a light‐emitting diode or x rays. These measurements include characterization of the drift and magnitude of the pixel dark signal, the size of the pixel switching transient, the temporal behavior of pixel sampling and the implied maximum frame rate, the dependence of relative pixel efficiency and pixel response on photodiode reverse bias voltage and operational mode, the degree of linearity of pixel response, and the trapping and release of charge from metastable states in the photodiodes. In addition, x‐ray sensitivity as a function of energy for a variety of phosphor screens for both fluoroscopic and radiographic operation is reported. Example images of a line‐pair pattern and an anthropomorphic phantom in each mode are presented along with a radiographic image of a human hand. General and specific improvements in imager design are described and anticipated developments are discussed. This represents the first systematic investigation of the operation and properties in both radiographic and fluoroscopic modes of an imager incorporating such an array. Signal properties of the first large‐area, high resolution, active matrix, flat‐panel imager are reported. The imager is based on an array of 1536×1920 pixels with a pixel‐to‐pixel pitch of 127 μm. Each pixel consists of a discrete amorphous silicon n‐i‐p photodiode coupled to an amorphous silicon thin‐film transistor. The imager detects incident x rays indirectly by means of an intensifying screen placed over the array. External acquisition electronics send control signals to the array and process analog imaging signals from the pixels. Considerations for operation of the imager in both fluoroscopic and radiographic modes are detailed and empirical signal performance data are presented with an emphasis on exploring similarities and differences between the two modes. Measurements which characterize the performance of the imager were performed as a function of operational parameters in the absence or presence of illumination from a light‐emitting diode or x rays. These measurements include characterization of the drift and magnitude of the pixel dark signal, the size of the pixel switching transient, the temporal behavior of pixel sampling and the implied maximum frame rate, the dependence of relative pixel efficiency and pixel response on photodiode reverse bias voltage and operational mode, the degree of linearity of pixel response, and the trapping and release of charge from metastable states in the photodiodes. In addition, x‐ray sensitivity as a function of energy for a variety of phosphor screens for both fluoroscopic and radiographic operation is reported. Example images of a line‐pair pattern and an anthropomorphic phantom in each mode are presented along with a radiographic image of a human hand. General and specific improvements in imager design are described and anticipated developments are discussed. This represents the first systematic investigation of the operation and properties in both radiographic and fluoroscopic modes of an imager incorporating such an array. |
Author | Huang, W. Street, R. A. Yorkston, J. Scarpine, V. E. Siewerdsen, J. H. El-Mohri, Y. Antonuk, L. E. |
Author_xml | – sequence: 1 givenname: L. E. surname: Antonuk fullname: Antonuk, L. E. organization: Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, Michigan 48109 – sequence: 2 givenname: Y. surname: El-Mohri fullname: El-Mohri, Y. organization: Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, Michigan 48109 – sequence: 3 givenname: J. H. surname: Siewerdsen fullname: Siewerdsen, J. H. organization: Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, Michigan 48109 – sequence: 4 givenname: J. surname: Yorkston fullname: Yorkston, J. organization: Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, Michigan 48109 – sequence: 5 givenname: W. surname: Huang fullname: Huang, W. organization: Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, Michigan 48109 – sequence: 6 givenname: V. E. surname: Scarpine fullname: Scarpine, V. E. organization: Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, Michigan 48109 – sequence: 7 givenname: R. A. surname: Street fullname: Street, R. A. organization: Xerox Palo Alto Research Center, 3333 Coyote Road, Palo Alto, California 94304 |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/9029541$$D View this record in MEDLINE/PubMed |
BookMark | eNp9UcFu1DAQtVBR2RYkfgDJJ9RKTbEdb2Ifq6qFSq3oAc7RxLGzRkkc7GRLv4pfZHazglM5jTzvzZvneSfkaAiDJeQ9Z5ecc_WJX651qbl6RVZClnkmBdNHZMWYlpmQbP2GnKT0gzFW5Gt2TI41E3ot-Yr8vulHH72Bjvpha9PkW5h8GGhwdNpYmnw7IDba6ELsYTB2hwDd-HaTRZtCN-_oFzjd-GjNRBs7Ydn3AOvW0h6m6H9R18GUjTBYXNVDayM9u3q4fbw7pyiN6BxiSCaM3lAYGhqh8aGNMG6wEdDA3tdb8tpBl-y7Qz0l329vvl1_ye6_fr67vrrPjOSlykRZFNCA5YIxpXkpciZKwQpnygJAcyulcggIJZSuQeG7rqXTUDMjjKnzU_Jx0R1j-DnjXareJ2O7Dv2HOVWlUiLHeSSeLUSD7lO0rhojfi8-V5xVu2wqXi3ZIPXDQXOue9v8JR7CQPxiwZ98Z59f1KkeHg9y5ws9GT_tj_O_1S9ytyH-kx4bl_8BjsS3Aw |
CODEN | MPHYA6 |
CitedBy_id | crossref_primary_10_1109_42_746724 crossref_primary_10_1118_1_598837 crossref_primary_10_1016_j_acra_2009_10_012 crossref_primary_10_1016_j_radphyschem_2011_09_010 crossref_primary_10_1118_1_1750992 crossref_primary_10_1118_1_598831 crossref_primary_10_3938_jkps_65_1969 crossref_primary_10_1118_1_2178452 crossref_primary_10_1016_S0168_9002_99_00275_2 crossref_primary_10_1118_1_1380213 crossref_primary_10_1118_1_1713298 crossref_primary_10_1118_1_1287053 crossref_primary_10_1118_1_4867867 crossref_primary_10_1118_1_1585051 crossref_primary_10_1053_crad_2000_0493 crossref_primary_10_1002_1522_2586_200102_13_2_294__AID_JMRI1042_3_0_CO_2_X crossref_primary_10_1118_1_1487858 crossref_primary_10_1088_0031_9155_45_9_316 crossref_primary_10_1118_1_1286721 crossref_primary_10_1118_1_2805993 crossref_primary_10_1118_1_2937652 crossref_primary_10_1002_mp_13791 crossref_primary_10_1007_s11426_018_9308_2 crossref_primary_10_1118_1_1413516 crossref_primary_10_1557_PROC_487_399 crossref_primary_10_1109_19_744358 crossref_primary_10_1557_opl_2012_840 crossref_primary_10_1088_0031_9155_53_5_011 crossref_primary_10_1118_1_3049602 crossref_primary_10_1118_1_4944868 crossref_primary_10_1016_j_apradiso_2008_10_007 crossref_primary_10_1118_1_1782676 crossref_primary_10_1118_1_3416924 crossref_primary_10_1118_1_1758350 crossref_primary_10_1118_1_2188082 crossref_primary_10_1016_S0026_2714_02_00024_0 crossref_primary_10_1118_1_3116364 crossref_primary_10_1118_1_598612 crossref_primary_10_1148_radiol_2272010839 crossref_primary_10_1118_1_1368878 crossref_primary_10_1118_1_598657 crossref_primary_10_1016_S1522_1865_98_00008_0 crossref_primary_10_1016_j_nima_2019_162364 crossref_primary_10_1118_1_2717405 crossref_primary_10_1118_1_3691180 crossref_primary_10_1080_14786430802709113 crossref_primary_10_1088_0022_3727_33_11_323 crossref_primary_10_1088_0031_9155_49_21_004 crossref_primary_10_1118_1_1376136 crossref_primary_10_1016_S0168_9002_01_02129_5 crossref_primary_10_1118_1_1357457 crossref_primary_10_1259_bjr_74_885_740789 crossref_primary_10_1109_TMI_2021_3063350 crossref_primary_10_3938_jkps_69_1168 crossref_primary_10_1016_j_semradonc_2005_01_003 crossref_primary_10_1109_23_856709 crossref_primary_10_1016_S0720_048X_99_00083_2 crossref_primary_10_1088_1361_6560_ad1999 crossref_primary_10_1118_1_598252 crossref_primary_10_1120_jacmp_v7i1_2158 crossref_primary_10_1118_1_598649 crossref_primary_10_1007_s00330_005_2734_9 crossref_primary_10_1063_1_1489485 crossref_primary_10_1118_1_2403967 crossref_primary_10_1016_j_nima_2013_05_174 crossref_primary_10_1016_S0360_3016_98_00210_7 crossref_primary_10_1118_1_1382609 crossref_primary_10_1118_1_597919 crossref_primary_10_1118_1_3259721 crossref_primary_10_1002_mp_13177 crossref_primary_10_5392_JKCA_2016_16_07_681 crossref_primary_10_1016_S0895_6111_97_00041_4 crossref_primary_10_1118_1_2008407 crossref_primary_10_1088_1361_6560_abbc82 crossref_primary_10_1118_1_1796091 crossref_primary_10_1088_0031_9155_50_12_012 crossref_primary_10_1118_1_598367 crossref_primary_10_1118_1_598243 crossref_primary_10_1118_1_599010 |
Cites_doi | 10.1016/0022-3093(96)00103-2 10.1117/12.208344 10.1117/12.206513 10.1016/S0360-3016(96)00358-6 10.1557/PROC-377-757 10.1117/12.208340 10.1109/16.370038 10.1117/12.208342 10.1117/12.237812 10.1557/PROC-192-441 10.1117/12.154598 10.1118/1.597628 10.1117/12.174247 10.1557/PROC-258-1145 10.1017/CBO9780511525247 10.1557/PROC-258-1069 10.1109/23.322874 10.1557/PROC-258-1127 10.1557/PROC-336-855 10.1118/1.597919 10.1080/13642819108205566 10.1148/radiographics.15.4.7569143 10.1557/PROC-258-1163 10.1117/12.59391 10.1118/1.597668 10.1118/1.596802 10.1557/PROC-297-945 10.1557/PROC-297-951 10.1117/12.43434 10.1143/JJAP.32.458 10.1117/12.174248 10.1117/12.59387 10.1109/23.322938 10.1557/PROC-297-939 10.1557/S0883769400046728 10.1117/12.148607 10.1557/PROC-219-173 |
ContentType | Journal Article |
Copyright | American Association of Physicists in Medicine 1997 American Association of Physicists in Medicine |
Copyright_xml | – notice: American Association of Physicists in Medicine – notice: 1997 American Association of Physicists in Medicine |
DBID | CGR CUY CVF ECM EIF NPM AAYXX CITATION 7X8 |
DOI | 10.1118/1.597918 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed CrossRef MEDLINE - Academic |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) CrossRef MEDLINE - Academic |
DatabaseTitleList | MEDLINE MEDLINE - Academic CrossRef |
Database_xml | – sequence: 1 dbid: ECM name: MEDLINE url: https://search.ebscohost.com/login.aspx?direct=true&db=cmedm&site=ehost-live sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine Physics |
EISSN | 2473-4209 |
EndPage | 70 |
ExternalDocumentID | 10_1118_1_597918 9029541 MP7918 |
Genre | article Research Support, U.S. Gov't, P.H.S Journal Article Comparative Study |
GrantInformation_xml | – fundername: NCI NIH HHS grantid: R01-CA56135 |
GroupedDBID | --- --Z -DZ .GJ 0R~ 1OB 1OC 29M 2WC 33P 36B 3O- 4.4 476 53G 5GY 5RE 5VS AAHHS AANLZ AAQQT AASGY AAXRX AAZKR ABCUV ABEFU ABFTF ABJNI ABLJU ABQWH ABTAH ABXGK ACAHQ ACBEA ACCFJ ACCZN ACGFO ACGFS ACGOF ACPOU ACSMX ACXBN ACXQS ADBBV ADBTR ADKYN ADOZA ADXAS ADZMN AEEZP AEGXH AEIGN AENEX AEQDE AEUYR AFBPY AFFPM AHBTC AIACR AIAGR AIURR AIWBW AJBDE ALMA_UNASSIGNED_HOLDINGS ALUQN AMYDB ASPBG BFHJK C45 CS3 DCZOG DRFUL DRMAN DRSTM DU5 EBD EBS EJD EMB EMOBN F5P G8K HDBZQ HGLYW I-F KBYEO LATKE LEEKS LOXES LUTES LYRES MEWTI O9- OVD P2P P2W PALCI PHY RJQFR RNS ROL SAMSI SUPJJ SV3 TEORI TN5 TWZ USG WOHZO WXSBR XJT ZGI ZVN ZXP ZY4 ZZTAW AITYG CGR CUY CVF ECM EIF NPM AAMNL AAYXX ABDPE CITATION 7X8 |
ID | FETCH-LOGICAL-c4178-2766adae1200891723027206fc76aa91e448f89128289ba8e44bb4f9ab0c2ccb3 |
IEDL.DBID | 33P |
ISSN | 0094-2405 |
IngestDate | Fri Oct 25 23:39:23 EDT 2024 Fri Nov 22 00:01:32 EST 2024 Sat Sep 28 07:38:23 EDT 2024 Sat Aug 24 01:03:11 EDT 2024 Fri Jun 21 00:29:02 EDT 2024 Sun Jul 14 10:05:18 EDT 2019 |
IsDoiOpenAccess | false |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 1 |
Keywords | 87.56.01.g 87.56.02 87.56.06 |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c4178-2766adae1200891723027206fc76aa91e448f89128289ba8e44bb4f9ab0c2ccb3 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
OpenAccessLink | http://deepblue.lib.umich.edu/bitstream/2027.42/135013/1/mp7918.pdf |
PMID | 9029541 |
PQID | 78823912 |
PQPubID | 23479 |
PageCount | 20 |
ParticipantIDs | pubmed_primary_9029541 wiley_primary_10_1118_1_597918_MP7918 proquest_miscellaneous_78823912 crossref_primary_10_1118_1_597918 scitation_primary_10_1118_1_597918 |
PublicationCentury | 1900 |
PublicationDate | 19970100 January 1997 1997-Jan 1997-01-00 19970101 |
PublicationDateYYYYMMDD | 1997-01-01 |
PublicationDate_xml | – month: 01 year: 1997 text: 19970100 |
PublicationDecade | 1990 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Medical physics (Lancaster) |
PublicationTitleAlternate | Med Phys |
PublicationYear | 1997 |
Publisher | American Association of Physicists in Medicine |
Publisher_xml | – name: American Association of Physicists in Medicine |
References | van Berkel, Bird, Curling, French (r8) 1993; 297 Antonuk, Boudry, Huang, McShan, Morton, Yorkston, Longo, Street (r2) 1992; 19 Yorkston, Antonuk, Seraji, Huang, Siewerdsen, El-Mohri (r20) 1995; 2432 Boudry, Antonuk (r40) 1996; 23 Antonuk, El-Mohri, Huang, Siewerdsen, Yorkston, Street (r18) 1994; 336 Yamaguchi, Kaneko, Tsutsui (r5) 1993; 32 Kobayashi, Makida, Sato, Hamano (r3) 1993; 1900 Antonuk, Yorkston, Huang, Boudry, Morton, Longo, Street (r36) 1992; 258 Antonuk, Boudry, Kim, Longo, Morton, Yorkston, Street (r21) 1991; 1443 Street, Fujieda, Weisfield, Nelson, Nylen (r30) 1992; 258 Siewerdsen, Antonuk, El-Mohri, Yorkston, Huang, Boudry, Cunningham (r19) 1997; 24 Matsunaga, Hatori, Hiroyuki, Yoshida (r31) 1995; 42 Street, Nelson, Antonuk, Mendez (r1) 1990; 192 Antonuk, Boudry, El-Mohri, Huang, Siewerdsen, Yorkston (r15) 1994; 2163 Morton, Antonuk, Berry, Huang, Mody, Yorkston (r25) 1994; 41 Schiff, Street, Weisfield (r37) 1996; 198–200 Schiebel, Conrads, Jung, Weibrecht, Wieczorek, Zaengel, Powell, French, Glasse (r39) 1994; 2163 Antonuk, Yorkston, Huang, Sandler, Siewerdsen, El-Mohri (r24) 1996; 36 Zhao, Rowlands (r7) 1995; 22 Chabbal, Chaussat, Ducourant, Fritsch, Michailos, Spinnler, Vieux, Arques, Hahm, Hoheisel, Horbaschek, Schulz, Spahn (r10) 1996; 2708 Zhao, Rowlands (r12) 1992; 1651 Antonuk, Yorkston, Huang, Siewerdsen, Street (r38) 1993; 297 Yorkston, Antonuk, Morton, Boudry, Huang, Kim, Longo, Street (r27) 1991; 219 Lee, Cheung, Jeromin (r6) 1995; 2432 Antonuk, Boudry, Yorkston, Morton, Huang, Street (r13) 1992; 1651 Yorkston, Antonuk, Seraji, Boudry, Huang, Morton, Street (r34) 1992; 258 Graeve, Huang, Alexander, Li (r11) 1995; 2415 Antonuk, Yorkston, Huang, Boudry, Morton, Street (r23) 1993; 1896 Powell, French, Hughes, Bird, Davies, Glasse, Curran (r4) 1992; 258 Yorkston, Antonuk, Huang, Street (r32) 1993; 297 Antonuk, Siewerdsen, Yorkston, Huang (r33) 1994; 41 Street, Wu, Weisfield, Ready, Apte, Nguyen, Nylen (r14) 1995; 377 Antonuk, Boudry, El-Mohri, Huang, Siewerdsen, Yorkston, Street (r17) 1995; 2432 1991; 1443 1995; 42 1994; 336 1992; 1651 1995; 2432 1993; 32 1995; 22 1995; 2415 1997; 24 1992; 258 1990; 192 1996; 2708 1992; 19 1996; 198–200 1995; 377 1996; 36 1993; 1900 1993; 297 1994; 41 1994; 2163 1991; 219 1996; 23 1993; 1896 e_1_2_1_42_1 e_1_2_1_20_1 e_1_2_1_41_1 e_1_2_1_40_1 e_1_2_1_23_1 e_1_2_1_24_1 e_1_2_1_21_1 e_1_2_1_22_1 e_1_2_1_43_1 e_1_2_1_27_1 e_1_2_1_28_1 e_1_2_1_25_1 e_1_2_1_26_1 e_1_2_1_29_1 e_1_2_1_7_1 e_1_2_1_31_1 e_1_2_1_8_1 e_1_2_1_30_1 e_1_2_1_5_1 e_1_2_1_6_1 e_1_2_1_3_1 e_1_2_1_12_1 e_1_2_1_35_1 e_1_2_1_4_1 e_1_2_1_13_1 e_1_2_1_34_1 e_1_2_1_10_1 e_1_2_1_33_1 e_1_2_1_2_1 e_1_2_1_11_1 e_1_2_1_32_1 e_1_2_1_16_1 e_1_2_1_39_1 e_1_2_1_17_1 e_1_2_1_38_1 e_1_2_1_14_1 e_1_2_1_37_1 e_1_2_1_15_1 e_1_2_1_36_1 e_1_2_1_9_1 e_1_2_1_18_1 e_1_2_1_19_1 |
References_xml | – volume: 297 start-page: 939 year: 1993 ident: r8 article-title: 2D image sensor arrays with nip diodes,” publication-title: Mater. Res. Soc. Symp. Proc. contributor: fullname: French – volume: 2708 start-page: 499 year: 1996 ident: r10 article-title: Amorphous silicon x ray image sensor publication-title: Proc. SPIE contributor: fullname: Spahn – volume: 2163 start-page: 129 year: 1994 ident: r39 article-title: Fluoroscopic x-ray imaging with amorphous silicon thin-film arrays publication-title: Proc. SPIE contributor: fullname: Glasse – volume: 1651 start-page: 94 year: 1992 ident: r13 article-title: Development of thin-film, flat-panel arrays for diagnostic and radiotherapy imaging,” publication-title: Proc. SPIE contributor: fullname: Street – volume: 32 start-page: 458 year: 1993 ident: r5 article-title: Two-dimensional contact-type image sensor using amorphous silicon photo-transistor,” publication-title: Jpn. J. Appl. Phys., Part 1 contributor: fullname: Tsutsui – volume: 297 start-page: 951 year: 1993 ident: r32 article-title: Photoresponse linearity of -Si:H imaging pixels,” publication-title: Mater. Res. Soc. Symp. Proc. contributor: fullname: Street – volume: 258 start-page: 1069 year: 1992 ident: r36 article-title: Factors affecting image quality for megavoltage and diagnostic x-ray -Si:H imaging arrays publication-title: Mater. Res. Soc. Symp. Proc. contributor: fullname: Street – volume: 41 start-page: 1150 year: 1994 ident: r25 article-title: A data acquisition system for flat-panel imaging arrays publication-title: IEEE Trans. Nucl. Sci. contributor: fullname: Yorkston – volume: 1900 start-page: 40 year: 1993 ident: r3 article-title: pixel -Si:H TFT driven 2-dimensional image sensor,” publication-title: Proc. SPIE contributor: fullname: Hamano – volume: 22 start-page: 1595 year: 1995 ident: r7 article-title: X-ray imaging using amorphous selenium: Feasibility of a flat panel self-scanned detector digital radiology,” publication-title: Med. Phys. contributor: fullname: Rowlands – volume: 192 start-page: 441 year: 1990 ident: r1 article-title: Amorphous silicon sensor arrays for radiation imaging publication-title: Mater. Res. Soc. Symp. Proc. contributor: fullname: Mendez – volume: 198–200 start-page: 1155 year: 1996 ident: r37 article-title: Reverse bias currents in amorphous silicon nip sensors publication-title: J. Non-Cryst. Solids contributor: fullname: Weisfield – volume: 258 start-page: 1145 year: 1992 ident: r30 article-title: Large area 2-dimensional -Si:H imaging arrays,” publication-title: Mater. Res. Soc. Symp. Proc. contributor: fullname: Nylen – volume: 336 start-page: 855 year: 1994 ident: r18 article-title: A large area, high-resolution -Si:H array for x-ray imaging publication-title: Mater. Res. Soc. Symp. Proc. contributor: fullname: Street – volume: 2415 start-page: 177 year: 1995 ident: r11 article-title: Amorphous silicon image sensor for x-ray applications,” publication-title: Proc. SPIE contributor: fullname: Li – volume: 1896 start-page: 18 year: 1993 ident: r23 article-title: Large area, flat-panel -Si:H arrays for x-ray imaging,” publication-title: Proc. SPIE contributor: fullname: Street – volume: 219 start-page: 173 year: 1991 ident: r27 article-title: The dynamic response of hydrogenated amorphous silicon imaging pixels,” publication-title: Mater. Res. Soc. Symp. Proc. contributor: fullname: Street – volume: 36 start-page: 661 year: 1996 ident: r24 article-title: Megavoltage imaging with a large area, flat-panel, amorphous silicon imaging array,” publication-title: Int. J. Radiat. Oncol., Biol., Phys. contributor: fullname: El-Mohri – volume: 258 start-page: 1127 year: 1992 ident: r4 article-title: Amorphous silicon image sensor arrays,” publication-title: Mater. Res. Soc. Symp. Proc. contributor: fullname: Curran – volume: 1651 start-page: 134 year: 1992 ident: r12 article-title: A large area solid-state detector for radiology using amorphous selenium,” publication-title: Proc. SPIE contributor: fullname: Rowlands – volume: 2432 start-page: 260 year: 1995 ident: r20 article-title: MTF measurements with high resolution -Si:H imaging arrays,” publication-title: Proc. SPIE contributor: fullname: El-Mohri – volume: 297 start-page: 945 year: 1993 ident: r38 article-title: Considerations for high frame rate operation of two-dimensional -Si:H imaging arrays publication-title: Mater. Res. Soc. Symp. Proc. contributor: fullname: Street – volume: 377 start-page: 757 year: 1995 ident: r14 article-title: Two dimensional amorphous silicon image sensor arrays,” publication-title: Mater. Res. Soc. Symp. Proc. contributor: fullname: Nylen – volume: 2432 start-page: 216 year: 1995 ident: r17 article-title: Large area, flat-panel amorphous silicon imagers publication-title: Proc. SPIE contributor: fullname: Street – volume: 2163 start-page: 118 year: 1994 ident: r15 article-title: A high resolution, high frame rate, flat-panel TFT array for digital x-ray imaging,” publication-title: Proc. SPIE contributor: fullname: Yorkston – volume: 1443 start-page: 108 year: 1991 ident: r21 article-title: Signal, noise and readout considerations in the development of amorphous silicon photodiode arrays for radiotherapy and diagnostic x-ray imaging,” publication-title: Proc. SPIE contributor: fullname: Street – volume: 19 start-page: 1445 year: 1992 ident: r2 article-title: Demonstration of megavoltage and diagnostic x-ray imaging with hydrogenated amorphous silicon arrays publication-title: Med. Phys. contributor: fullname: Street – volume: 42 start-page: 38 year: 1995 ident: r31 article-title: Analysis of signal to noise ratio of photoconductive layered solid-state imaging device,” publication-title: IEEE Trans. Electron Devices contributor: fullname: Yoshida – volume: 258 start-page: 1163 year: 1992 ident: r34 article-title: Comparison of computer simulations with measurements from -Si:H imaging arrays publication-title: Mater. Res. Soc. Symp. Proc. contributor: fullname: Street – volume: 2432 start-page: 237 year: 1995 ident: r6 article-title: A new digital detector for projection radiography,” publication-title: Proc. SPIE contributor: fullname: Jeromin – volume: 24 start-page: 71 year: 1997 ident: r19 article-title: Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology,” publication-title: Med. Phys. contributor: fullname: Cunningham – volume: 41 start-page: 1500 year: 1994 ident: r33 article-title: Radiation response of amorphous silicon imaging arrays at diagnostic energies,” publication-title: IEEE Trans. Nucl. Sci. contributor: fullname: Huang – volume: 23 start-page: 743 year: 1996 ident: r40 article-title: Radiation damage of amorphous silicon, thin-film, field-effect transistors publication-title: Med. Phys. contributor: fullname: Antonuk – volume: 2163 start-page: 118 year: 1994 end-page: 128 article-title: A high resolution, high frame rate, flat‐panel TFT array for digital x‐ray imaging,” publication-title: Proc. SPIE – volume: 2415 start-page: 177 year: 1995 end-page: 181 article-title: Amorphous silicon image sensor for x‐ray applications,” publication-title: Proc. SPIE – volume: 24 start-page: 71 year: 1997 end-page: 89 article-title: Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat‐panel imagers (AMFPIs) for diagnostic radiology,” publication-title: Med. Phys. – volume: 36 start-page: 661 year: 1996 end-page: 672 article-title: Megavoltage imaging with a large area, flat‐panel, amorphous silicon imaging array,” publication-title: Int. J. Radiat. Oncol., Biol., Phys. – volume: 22 start-page: 1595 year: 1995 end-page: 1604 article-title: X‐ray imaging using amorphous selenium: Feasibility of a flat panel self‐scanned detector digital radiology,” publication-title: Med. Phys. – volume: 41 start-page: 1500 year: 1994 end-page: 1505 article-title: Radiation response of amorphous silicon imaging arrays at diagnostic energies,” publication-title: IEEE Trans. Nucl. Sci. – volume: 258 start-page: 1145 year: 1992 end-page: 1150 article-title: Large area 2‐dimensional ‐Si:H imaging arrays,” publication-title: Mater. Res. Soc. Symp. Proc. – volume: 258 start-page: 1163 year: 1992 end-page: 1168 article-title: Comparison of computer simulations with measurements from ‐Si:H imaging arrays publication-title: Mater. Res. Soc. Symp. Proc. – volume: 42 start-page: 38 year: 1995 end-page: 42 article-title: Analysis of signal to noise ratio of photoconductive layered solid‐state imaging device,” publication-title: IEEE Trans. Electron Devices – volume: 297 start-page: 945 year: 1993 end-page: 950 article-title: Considerations for high frame rate operation of two‐dimensional ‐Si:H imaging arrays publication-title: Mater. Res. Soc. Symp. Proc. – volume: 377 start-page: 757 year: 1995 end-page: 765 article-title: Two dimensional amorphous silicon image sensor arrays,” publication-title: Mater. Res. Soc. Symp. Proc. – volume: 258 start-page: 1127 year: 1992 end-page: 1137 article-title: Amorphous silicon image sensor arrays,” publication-title: Mater. Res. Soc. Symp. Proc. – volume: 2708 start-page: 499 year: 1996 end-page: 510 article-title: Amorphous silicon x ray image sensor publication-title: Proc. SPIE – volume: 336 start-page: 855 year: 1994 end-page: 860 article-title: A large area, high‐resolution ‐Si:H array for x‐ray imaging publication-title: Mater. Res. Soc. Symp. Proc. – volume: 1443 start-page: 108 year: 1991 end-page: 119 article-title: Signal, noise and readout considerations in the development of amorphous silicon photodiode arrays for radiotherapy and diagnostic x‐ray imaging,” publication-title: Proc. SPIE – volume: 19 start-page: 1445 year: 1992 end-page: 1466 article-title: Demonstration of megavoltage and diagnostic x‐ray imaging with hydrogenated amorphous silicon arrays publication-title: Med. Phys. – volume: 32 start-page: 458 year: 1993 end-page: 461 article-title: Two‐dimensional contact‐type image sensor using amorphous silicon photo‐transistor,” publication-title: Jpn. J. Appl. Phys., Part 1 – volume: 192 start-page: 441 year: 1990 end-page: 452 article-title: Amorphous silicon sensor arrays for radiation imaging publication-title: Mater. Res. Soc. Symp. Proc. – volume: 1896 start-page: 18 year: 1993 end-page: 29 article-title: Large area, flat‐panel ‐Si:H arrays for x‐ray imaging,” publication-title: Proc. SPIE – volume: 219 start-page: 173 year: 1991 end-page: 178 article-title: The dynamic response of hydrogenated amorphous silicon imaging pixels,” publication-title: Mater. Res. Soc. Symp. Proc. – volume: 297 start-page: 939 year: 1993 end-page: 944 article-title: 2D image sensor arrays with nip diodes,” publication-title: Mater. Res. Soc. Symp. Proc. – volume: 1651 start-page: 134 year: 1992 end-page: 143 article-title: A large area solid‐state detector for radiology using amorphous selenium,” publication-title: Proc. SPIE – volume: 2432 start-page: 260 year: 1995 end-page: 269 article-title: MTF measurements with high resolution ‐Si:H imaging arrays,” publication-title: Proc. SPIE – volume: 258 start-page: 1069 year: 1992 end-page: 1074 article-title: Factors affecting image quality for megavoltage and diagnostic x‐ray ‐Si:H imaging arrays publication-title: Mater. Res. Soc. Symp. Proc. – volume: 23 start-page: 743 year: 1996 end-page: 754 article-title: Radiation damage of amorphous silicon, thin‐film, field‐effect transistors publication-title: Med. Phys. – volume: 2432 start-page: 237 year: 1995 end-page: 249 article-title: A new digital detector for projection radiography,” publication-title: Proc. SPIE – volume: 198–200 start-page: 1155 year: 1996 end-page: 1158 article-title: Reverse bias currents in amorphous silicon nip sensors publication-title: J. Non‐Cryst. Solids – volume: 2163 start-page: 129 year: 1994 end-page: 140 article-title: Fluoroscopic x‐ray imaging with amorphous silicon thin‐film arrays publication-title: Proc. SPIE – volume: 297 start-page: 951 year: 1993 end-page: 956 article-title: Photoresponse linearity of ‐Si:H imaging pixels,” publication-title: Mater. Res. Soc. Symp. Proc. – volume: 1651 start-page: 94 year: 1992 end-page: 105 article-title: Development of thin‐film, flat‐panel arrays for diagnostic and radiotherapy imaging,” publication-title: Proc. SPIE – volume: 41 start-page: 1150 year: 1994 end-page: 1154 article-title: A data acquisition system for flat‐panel imaging arrays publication-title: IEEE Trans. Nucl. Sci. – volume: 1900 start-page: 40 year: 1993 end-page: 46 article-title: pixel ‐Si:H TFT driven 2‐dimensional image sensor,” publication-title: Proc. SPIE – volume: 2432 start-page: 216 year: 1995 end-page: 227 article-title: Large area, flat‐panel amorphous silicon imagers publication-title: Proc. SPIE – ident: e_1_2_1_38_1 doi: 10.1016/0022-3093(96)00103-2 – ident: e_1_2_1_21_1 doi: 10.1117/12.208344 – ident: e_1_2_1_12_1 doi: 10.1117/12.206513 – ident: e_1_2_1_25_1 doi: 10.1016/S0360-3016(96)00358-6 – ident: e_1_2_1_15_1 doi: 10.1557/PROC-377-757 – ident: e_1_2_1_43_1 – ident: e_1_2_1_18_1 doi: 10.1117/12.208340 – ident: e_1_2_1_32_1 doi: 10.1109/16.370038 – ident: e_1_2_1_7_1 doi: 10.1117/12.208342 – ident: e_1_2_1_11_1 doi: 10.1117/12.237812 – ident: e_1_2_1_2_1 doi: 10.1557/PROC-192-441 – ident: e_1_2_1_24_1 doi: 10.1117/12.154598 – ident: e_1_2_1_8_1 doi: 10.1118/1.597628 – ident: e_1_2_1_16_1 doi: 10.1117/12.174247 – ident: e_1_2_1_31_1 doi: 10.1557/PROC-258-1145 – ident: e_1_2_1_29_1 doi: 10.1017/CBO9780511525247 – ident: e_1_2_1_37_1 doi: 10.1557/PROC-258-1069 – ident: e_1_2_1_26_1 doi: 10.1109/23.322874 – ident: e_1_2_1_5_1 doi: 10.1557/PROC-258-1127 – ident: e_1_2_1_19_1 doi: 10.1557/PROC-336-855 – ident: e_1_2_1_20_1 doi: 10.1118/1.597919 – ident: e_1_2_1_42_1 – ident: e_1_2_1_27_1 doi: 10.1080/13642819108205566 – ident: e_1_2_1_36_1 doi: 10.1148/radiographics.15.4.7569143 – ident: e_1_2_1_17_1 – ident: e_1_2_1_35_1 doi: 10.1557/PROC-258-1163 – ident: e_1_2_1_13_1 doi: 10.1117/12.59391 – ident: e_1_2_1_41_1 doi: 10.1118/1.597668 – ident: e_1_2_1_3_1 doi: 10.1118/1.596802 – ident: e_1_2_1_39_1 doi: 10.1557/PROC-297-945 – ident: e_1_2_1_33_1 doi: 10.1557/PROC-297-951 – ident: e_1_2_1_22_1 doi: 10.1117/12.43434 – ident: e_1_2_1_6_1 doi: 10.1143/JJAP.32.458 – ident: e_1_2_1_40_1 doi: 10.1117/12.174248 – ident: e_1_2_1_14_1 doi: 10.1117/12.59387 – ident: e_1_2_1_30_1 – ident: e_1_2_1_34_1 doi: 10.1109/23.322938 – ident: e_1_2_1_9_1 doi: 10.1557/PROC-297-939 – ident: e_1_2_1_23_1 doi: 10.1557/S0883769400046728 – ident: e_1_2_1_4_1 doi: 10.1117/12.148607 – ident: e_1_2_1_10_1 – ident: e_1_2_1_28_1 doi: 10.1557/PROC-219-173 |
SSID | ssj0006350 |
Score | 1.9202335 |
Snippet | Signal properties of the first large-area, high resolution, active matrix, flat-panel imager are reported. The imager is based on an array of 1536×1920 pixels... Signal properties of the first large‐area, high resolution, active matrix, flat‐panel imager are reported. The imager is based on an array of 1536×1920 pixels... Signal properties of the first large-area, high resolution, active matrix, flat-panel imager are reported. The imager is based on an array of 1536 x 1920... |
SourceID | proquest crossref pubmed wiley scitation |
SourceType | Aggregation Database Index Database Publisher Enrichment Source |
StartPage | 51 |
SubjectTerms | 87.56.01.g 87.56.02 87.56.06 Amorphous semiconductors biomedical equipment Bone and Bones - diagnostic imaging diagnostic radiography Electronics Equipment Design Fluoroscopy Fluoroscopy - instrumentation Fluoroscopy - methods Hand - diagnostic imaging Humans Illumination Medical imaging Medical X‐ray imaging Non‐ionizing radiation equipment and techniques Phantoms, Imaging photodiodes Process monitoring and control Radiography Radiography - instrumentation Radiography - methods Sensitivity and Specificity Thin film transistors X-Ray Film X-Rays X‐ray detectors X‐ray imaging |
Title | Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation |
URI | http://dx.doi.org/10.1118/1.597918 https://onlinelibrary.wiley.com/doi/abs/10.1118%2F1.597918 https://www.ncbi.nlm.nih.gov/pubmed/9029541 https://search.proquest.com/docview/78823912 |
Volume | 24 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1bS9xAFD5YQVsf6qWVpq11lBZaaNpMNmsmvkndRR9WFqzQtzC3wEI3CXsRH_0J_hf_UX9Jz5nJRsRaCn0KyVySMOc655xvAN5LkcZdoVXIO2kUJoUoQpklChmvUCo9QB3o0PZPztOzH-K4RzA5h4taGI8P0W64EWc4eU0MLlVzCgmnxHX-BW3hjFOdLzoJrnqjM2yFMOpRX32SJRRA6Da4szj062LgfU30wLxcg6eohHw8_L7l6lRPf_1_PnoDnjcGJzvyFLIJS7bcgtVBE1LfghWXA6qnL-C2N65HDjGEje7QN6qSVQVDM5FRqge21XelBtQiGSEe_7q-Qb-9IePPjALhJEqZsTOX64XPpJOsbExnAlyx4qec4SCURRZfNyYkDfbxaNAfnn5iOD22zysC2qzqkWayNGwizcjDa-ODqraecl_CRb_3_dtJ2JzpEOqEo8Ma4_pLIy2nvAt0FWOKm8YRVRwdSJlxi-5igQ3OE1RS4L1SSZFJFelYa9XZhuWyKu0rYF0pEuyC3r1Am85qpXFMZKQQJkpSEwWwt1jfvPbQHbl3eUTOc78OAewuFj5HvqJgCf53NZ_mKboeHfyOALY9PbRzZBHFRnkA-y19_GX-P3S6rCZth7w2RQAfHM08Oks-GNLl9T_2ewPPPMgubRS9heXZZG534MnUzN85JvkNEioUaA |
link.rule.ids | 315,782,786,1408,27933,27934,46064,46488 |
linkProvider | Wiley-Blackwell |
linkToHtml | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1ba9RAFD7YFq0-tFpbGi_tKAoKTZtks5sJPhXdZYvdsmAF34a5BRa6SdiL-OhP8L_4j_wlnjOTTSleEHwKyVwyYc51zjlfAF5IniVdrlUYd7IoTAtehDJPFTJeoVTWQx3o0PaHH7KLT_xdn2By3qxqYTw-RHvgRpzh5DUxOB1IN1xOmevxMRrDeczXYCPtIR1S_UZn3Iph1KS-_iRPKYTQbZBncezJauRNXfSLgXkPNlEN-Yj4TdvVKZ_B9n8t-z5sNTYnO_VE8gBu2XIH7oyaqPoO3HZpoHr-EL73p_XEgYawyTUAR1WyqmBoKTLK9sC2-rragFokI9DjH1-_oeveUPIRo1g4SVNm7MKle-Ez6YQrm9JvAb6w4koucBCKI4uvmxKYBnt1OhqMz14znB7blxVhbVb1RDNZGjaTZuIRtvFBVVtPvLvwcdC_fDsMm986hDqN0WdNkASkkTam1Av0FhMKnSYRFR31pMxjix5jgQ3OGVSS471SaZFLFelEa9XZg_WyKu0-sK7kKXZBB5-jWWe10jgmMpJzE6WZiQJ4ttpgUXv0DuG9Hi5i4fchgMPVzgtkLYqX4HdXy7nI0Pvo4DoC2PME0c6RRxQejQN43hLIX-b_TafP1aztIGpTBPDSEc0fZxGjMV0e_WO_Q9gcXo7OxfnZxfvHcNdj7tK50RNYX8yW9imszc3ywHHMT25IGJA |
linkToPdf | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1ba9RAFD70gq0-VK0txltHUWjBaG7bTPpW7C4tumVBhb4NcwssuEnYi_joT-h_6T_yl3jOTDaleEHwKWRumTDnOufMNwAvJc-THtcqjNM8CrOSl6EsMoWMVyqVH6IOdGj7px_z8wt-0ieYnKPlWRiPD9FtuBFnOHlNDN6YsmVySlyP36AtXMR8FdYztMIJNz9NR50URkXqj58UGUUQei3wLPZ9u-x5UxX9Yl_egU3UQj4gftN0dbpncPd_Zn0PtlqLkx17ErkPK7baho1hG1PfhlsuCVTPHsBVf9KMHWQIG1_Db9QVq0uGdiKjXA-sa67PGlCNZAR5_OP7JTruLR2_ZhQJJ1nKjJ27ZC8sk060sgldCvCNlV_kHDuhMLL4uQlBabD94-FgdHbAcHisX9SEtFk3Y81kZdhUmrHH18aCurGedHfg86D_6d1p2F7qEOosRo81QQKQRtqYEi_QV0wocJpEdOToUMoitugvlljhXEElOb4rlZWFVJFOtFbpLqxVdWUfAutJnmETdO85GnVWK419IiM5N1GWmyiA58v1FY3H7hDe5-EiFn4dAthbLrxAxqJoCf53vZiJHH2PFOcRwK6nh26MIqLgaBzAi44-_jL-bxp9raddA4H0EcArRzN_HEUMR_R49I_t9mBjdDIQH87O3z-G2x5wlzaNnsDafLqwT2F1ZhbPHL_8BPgCFzY |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Empirical+investigation+of+the+signal+performance+of+a+high%E2%80%90resolution%2C+indirect+detection%2C+active+matrix+flat%E2%80%90panel+imager+%28AMFPI%29+for+fluoroscopic+and+radiographic+operation&rft.jtitle=Medical+physics+%28Lancaster%29&rft.au=Antonuk%2C+L.+E.&rft.au=El%E2%80%90Mohri%2C+Y.&rft.au=Siewerdsen%2C+J.+H.&rft.au=Yorkston%2C+J.&rft.date=1997-01-01&rft.pub=American+Association+of+Physicists+in+Medicine&rft.issn=0094-2405&rft.eissn=2473-4209&rft.volume=24&rft.issue=1&rft.spage=51&rft.epage=70&rft_id=info:doi/10.1118%2F1.597918&rft.externalDBID=10.1118%252F1.597918&rft.externalDocID=MP7918 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0094-2405&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0094-2405&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0094-2405&client=summon |