Diagnostic Performance of a Novel Three-Dimensional Neuroretinal Rim Parameter for Glaucoma Using High-Density Volume Scans

To evaluate the diagnostic performance of a 3-dimensional (3D) neuroretinal rim parameter, the minimum distance band (MDB), using optical coherence tomography (OCT) high-density volume scans for open-angle glaucoma. Reliability analysis. setting: Institutional. study population: Total of 163 patient...

Full description

Saved in:
Bibliographic Details
Published in:American journal of ophthalmology Vol. 169; pp. 168 - 178
Main Authors: Shieh, Eric, Lee, Ramon, Que, Christian, Srinivasan, Vivek, Guo, Rong, DeLuna, Regina, Pandit, Sumir, Simavli, Huseyin, Seevaratnam, Rajini, Tsikata, Edem, de Boer, Johannes, Chen, Teresa C.
Format: Journal Article
Language:English
Published: United States Elsevier Inc 01-09-2016
Elsevier Limited
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To evaluate the diagnostic performance of a 3-dimensional (3D) neuroretinal rim parameter, the minimum distance band (MDB), using optical coherence tomography (OCT) high-density volume scans for open-angle glaucoma. Reliability analysis. setting: Institutional. study population: Total of 163 patients (105 glaucoma and 58 healthy subjects). observation procedures: One eye of each patient was included. MDB and retinal nerve fiber layer (RNFL) thickness values were determined for 4 quadrants and 4 sectors using a spectral-domain OCT device. main outcome measures: Area under the receiver operating characteristic curve (AUROC) values, sensitivities, specificities, and positive and negative predictive values. The best AUROC values of 3D MDB thickness for glaucoma and early glaucoma were for the overall globe (0.969, 0.952), followed by the inferior quadrant (0.966, 0.949) and inferior-temporal sector (0.966, 0.944), and then followed by the superior-temporal sector (0.964, 0.932) and superior quadrant (0.962, 0.924). All 3D MDB thickness AUROC values were higher than those of 2D RNFL thickness. Pairwise comparisons showed that the diagnostic performance of the 3D MDB parameter was significantly better than 2D RNFL thickness only for the nasal quadrant and inferior-nasal and superior-nasal sectors (P = .023–.049). Combining 3D MDB with 2D RNFL parameters provided significantly better diagnostic performance (AUROC 0.984) than most single MDB parameters and all single RNFL parameters. Compared with the 2D RNFL thickness parameter, the 3D MDB neuroretinal rim thickness parameter had uniformly equal or better diagnostic performance for glaucoma in all regions and was significantly better in the nasal region.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0002-9394
1879-1891
DOI:10.1016/j.ajo.2016.06.028