A semi-automated, isotope-dilution high-resolution mass spectrometry assay for therapeutic drug monitoring of antidepressants

Therapeutic drug monitoring (TDM) of antidepressants is important to ensure compliance and to rule out pharmacokinetic abnormalities. Therefore, reliable methods for quantification are important for clinical laboratories. Most of the currently used mass spectrometry methods use triple quadrupoles as...

Full description

Saved in:
Bibliographic Details
Published in:Clinical mass spectrometry (Del Mar, Calif.) Vol. 14 Pt B; pp. 89 - 98
Main Authors: Lindner, Johanna M, Vogeser, Michael, Sorg, Katharina, Grimm, Stefanie H
Format: Journal Article
Language:English
Published: Netherlands Elsevier 01-11-2019
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Therapeutic drug monitoring (TDM) of antidepressants is important to ensure compliance and to rule out pharmacokinetic abnormalities. Therefore, reliable methods for quantification are important for clinical laboratories. Most of the currently used mass spectrometry methods use triple quadrupoles as mass analyzers. We aimed to develop a method using high-resolution mass spectrometry (HRMS) and wanted to test the suitability of this analyzer for quantitative TDM assays. This would be beneficial since HRMS instruments can also be used for metabolomics and protein analysis and, thus, many different analyses could be run on one instrument. After manual protein precipitation of serum samples, further sample clean-up was achieved using a Turbo Flow column preconnected to the analytical LC column. Stable isotope-labelled counterparts of the target analytes were used as internal standards. For detection, we used a Q Exactive Focus Orbitrap mass spectrometer operating in full-scan mode. Ionization was performed in positive ESI. Accuracy, recovery, and matrix effect were acceptable for all analytes. The method demonstrated outstanding precision (within-run imprecision <4.5%, between-run imprecision <7.5%). The selectivity of the method was ensured by chromatographic separation of all isobaric compounds. Close agreement between Orbitrap and triple stage based quantification was observed in a comparison measurement of leftover patient samples. We have established a selective method for the quantification of antidepressants with outstanding precision using a high-resolution Orbitrap mass spectrometer. The applicability of HRMS instruments to TDM was demonstrated.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2376-9998
2213-8005
2376-9998
DOI:10.1016/j.clinms.2019.05.004