A new technique for right heart catheterization with a Swan-Ganz balloon catheter via femoral vein in the patient with dilated right heart chambers, utilizing a modified transseptal-type sheath
Right heart catheterization with a Swan-Ganz balloon catheter via femoral vein in the patient with dilated right atrium and ventricle is frequently difficult due to excessive catheter coiling in the dilated atrium. A new technique is described in this situation. By using a modified transseptal-type...
Saved in:
Published in: | Catheterization and cardiovascular diagnosis Vol. 23; no. 1; p. 54 |
---|---|
Main Authors: | , |
Format: | Journal Article |
Language: | English |
Published: |
United States
01-05-1991
|
Subjects: | |
Online Access: | Get more information |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Right heart catheterization with a Swan-Ganz balloon catheter via femoral vein in the patient with dilated right atrium and ventricle is frequently difficult due to excessive catheter coiling in the dilated atrium. A new technique is described in this situation. By using a modified transseptal-type sheath positioned counterclockwise in right atrium as an introducing sheath, a balloon catheter can be easily advanced to the distal pulmonary artery by smooth counterclockwise direction and secure support from this sheath. |
---|---|
ISSN: | 0098-6569 |
DOI: | 10.1002/ccd.1810230115 |