A less traumatic catheter for coronary arteriography
A deformable soft-tipped angiographic catheter has been designed and developed to reduce vascular trauma during coronary arteriography. In order to test the ability of the catheter tip glide over vascular endothelium, the coefficient of resistance was tested using fresh human aortic tissue. The mean...
Saved in:
Published in: | Catheterization and cardiovascular diagnosis Vol. 11; no. 2; p. 187 |
---|---|
Main Authors: | , , , , |
Format: | Journal Article |
Language: | English |
Published: |
United States
1985
|
Subjects: | |
Online Access: | Get more information |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Abstract | A deformable soft-tipped angiographic catheter has been designed and developed to reduce vascular trauma during coronary arteriography. In order to test the ability of the catheter tip glide over vascular endothelium, the coefficient of resistance was tested using fresh human aortic tissue. The mean frictional coefficients of resistance (FRc) for the soft-tipped catheter, as compared with two commonly used catheters (N = 10/group), were .78 +/- .08 units for the soft-tipped catheter and 1.10 +/- .10 (p less than .006) and .98 +/- .10 (p less than .034) for the conventional catheters. This demonstrates a significant 23% reduction in FRc with the soft-tipped catheter. The ease of penetration into a wax media was also measured using the soft-tipped catheter and compared with the same two conventional catheters. The indentation depths for the soft-tipped catheter and the two other catheter groups (N = 7/group) were 140 +/- 18 micron, 246 +/- 15 micron and 318 +/- 20 micron, respectively. This represents a 56% decrease in indentation depth with the soft-tipped catheter. Histologic studies in canines have demonstrated considerably less endothelial damage and subsequent intimal proliferation in the aorta and coronary ostia with the soft-tipped catheters compared with control catheters. It is concluded that a soft-tipped angiographic catheter is less traumatic to vascular tissue and may offer a safer approach to intravascular studies. |
---|---|
AbstractList | A deformable soft-tipped angiographic catheter has been designed and developed to reduce vascular trauma during coronary arteriography. In order to test the ability of the catheter tip glide over vascular endothelium, the coefficient of resistance was tested using fresh human aortic tissue. The mean frictional coefficients of resistance (FRc) for the soft-tipped catheter, as compared with two commonly used catheters (N = 10/group), were .78 +/- .08 units for the soft-tipped catheter and 1.10 +/- .10 (p less than .006) and .98 +/- .10 (p less than .034) for the conventional catheters. This demonstrates a significant 23% reduction in FRc with the soft-tipped catheter. The ease of penetration into a wax media was also measured using the soft-tipped catheter and compared with the same two conventional catheters. The indentation depths for the soft-tipped catheter and the two other catheter groups (N = 7/group) were 140 +/- 18 micron, 246 +/- 15 micron and 318 +/- 20 micron, respectively. This represents a 56% decrease in indentation depth with the soft-tipped catheter. Histologic studies in canines have demonstrated considerably less endothelial damage and subsequent intimal proliferation in the aorta and coronary ostia with the soft-tipped catheters compared with control catheters. It is concluded that a soft-tipped angiographic catheter is less traumatic to vascular tissue and may offer a safer approach to intravascular studies. |
Author | MacCarter, D J Rydell, M A Vlodaver, Z Van Tassel, R A Gobel, F L |
Author_xml | – sequence: 1 givenname: R A surname: Van Tassel fullname: Van Tassel, R A – sequence: 2 givenname: F L surname: Gobel fullname: Gobel, F L – sequence: 3 givenname: M A surname: Rydell fullname: Rydell, M A – sequence: 4 givenname: Z surname: Vlodaver fullname: Vlodaver, Z – sequence: 5 givenname: D J surname: MacCarter fullname: MacCarter, D J |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/3986900$$D View this record in MEDLINE/PubMed |
BookMark | eNotzrlqAzEUhWEVDo6XtOkCeoFx7pU0WkpjkjhgSBPXRms8wbMgjQu_fQbi6sBfHL4lmXV9Fwl5RtggAHv1PmxQIyACQ5yRBYDRlayleSTLUn4BQEgu5mTOjZYGYEHEll5iKXTM9trasfHU2_Ecx5hp6jP1fe47m2_U5ik1_U-2w_m2Jg_JXkp8uu-KHN_fvnf76vD18bnbHiovQGHltBKx9jW64JNRqJUDlJMtpmCk4RiUSyIZgc4HbSKg5gmYFrwOXHDBVuTl_3e4ujaG05CbdsKc7nr2B5B-RZY |
CitedBy_id | crossref_primary_10_1002_ccd_1810120515 crossref_primary_10_1016_0002_9149_89_90879_5 crossref_primary_10_1016_S0025_6196_12_60956_2 crossref_primary_10_4103_0972_0820_304628 crossref_primary_10_1007_s10856_013_4953_y crossref_primary_10_1002_ccd_1810130112 crossref_primary_10_1016_S0735_1097_97_00558_5 crossref_primary_10_1002_ccd_1810120410 crossref_primary_10_1002_ccd_1810180416 crossref_primary_10_1111_j_1540_8183_1988_tb00408_x |
ContentType | Journal Article |
DBID | CGR CUY CVF ECM EIF NPM |
DOI | 10.1002/ccd.1810110211 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: ECM name: MEDLINE url: https://search.ebscohost.com/login.aspx?direct=true&db=cmedm&site=ehost-live sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
Discipline | Medicine |
ExternalDocumentID | 3986900 |
Genre | Journal Article |
GroupedDBID | .GA .GJ .Y3 10A 1L6 1OB 1OC 1ZS 29B 31~ 3WU 4ZD 51W 51X 52N 52O 52P 52R 52S 52T 52W 52X 53G 5GY 5RE 66C 7PT 8-1 8-4 8-5 930 A01 A03 AAEVG AAHHS AANLZ AAXRX AAZKR ABCUV ABIJN ABJNI ABQWH ABXGK ACAHQ ACBWZ ACCFJ ACCZN ACGFS ACMXC ACPOU ACXBN ACXQS ADBTR ADEOM ADIZJ ADMGS ADOZA ADZOD AEEZP AEIGN AEIMD AEQDE AEUQT AEUYR AFBPY AFFPM AFGKR AFPWT AFZJQ AHBTC AIACR AITYG AIURR AIWBW AJBDE ALMA_UNASSIGNED_HOLDINGS ALUQN AMBMR AMYDB ASPBG ATUGU AVWKF AZFZN BDRZF BPMNR BRXPI BY8 CGR CO8 CS3 CUY CVF D-7 D-F DCZOG DRFUL DRMAN DRSTM ECM EIF F00 F01 F04 F5P FEDTE G-S GODZA HGLYW HHY HHZ HVGLF J5H JPC KQQ LATKE LAW LEEKS LH4 LITHE LOXES LP6 LP7 LUTES LYRES M65 MEWTI MRFUL MRMAN MRSTM MSFUL MSMAN MSSTM MXFUL MXMAN MXSTM NPM P4B P4D PALCI QB0 QRW RGB RIWAO ROL RWI SAMSI SUPJJ UB1 W99 WIH WIJ WIK WJL WQJ WRC WUP WXI WXSBR XG1 XV2 ZGI ZXP ZZTAW |
ID | FETCH-LOGICAL-c4071-b874e5c51bdcf97187b016102efd96931d7bf4f941bcd89e0183f028435d34342 |
ISSN | 0098-6569 |
IngestDate | Sat Sep 28 08:37:02 EDT 2024 |
IsPeerReviewed | false |
IsScholarly | false |
Issue | 2 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c4071-b874e5c51bdcf97187b016102efd96931d7bf4f941bcd89e0183f028435d34342 |
PMID | 3986900 |
ParticipantIDs | pubmed_primary_3986900 |
PublicationCentury | 1900 |
PublicationDate | 1985-00-00 |
PublicationDateYYYYMMDD | 1985-01-01 |
PublicationDate_xml | – year: 1985 text: 1985-00-00 |
PublicationDecade | 1980 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Catheterization and cardiovascular diagnosis |
PublicationTitleAlternate | Cathet Cardiovasc Diagn |
PublicationYear | 1985 |
SSID | ssj0004634 |
Score | 1.2085711 |
Snippet | A deformable soft-tipped angiographic catheter has been designed and developed to reduce vascular trauma during coronary arteriography. In order to test the... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 187 |
SubjectTerms | Angiography Animals Aorta, Abdominal - injuries Aorta, Abdominal - pathology Aorta, Thoracic - injuries Aorta, Thoracic - pathology Cardiac Catheterization - adverse effects Cardiac Catheterization - instrumentation Coronary Angiography Coronary Vessels - injuries Coronary Vessels - pathology Dogs Humans |
Title | A less traumatic catheter for coronary arteriography |
URI | https://www.ncbi.nlm.nih.gov/pubmed/3986900 |
Volume | 11 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV27TsMwFLUoCNQF8RRvZWCrAnHiJPZYlRaWMpRSIZYqfkmVSlsBHfh7rmM3SYsQMLBEke1Ese_xzbF9fYzQpc50An8p7rNEch96YuxTKrQvRIA51jRjMj_E9iG9f6I3bdIulwvKtH-1NKSBrc3O2T9Yu3gpJMA92ByuYHW4_sruzcbYOK_312xu1VhzYVYjhWgCCoURLDCBcnko56iqV13IFdjibn-m3fe2HLQqbXjeqKDjA3ASfWDhdsW_V86P3k65Tes0iknm3od0ax3dsuBgPJWZCyZ9LmciMKNxZSbCeVdGfeCHbMm74gqKwoqrxPZH-8WFW0lYIeQVNuJj5uhxXC0IzT17yY0XMXOcVvBj5oqgtsupoRqwI0OgW93KTtqILFRWTU0WMp9BeL38RXW06d6zMh7JeUl_B227AYXXtEjYRWtqsoe2ui5kYh-RpmcA4RWA8BaA8AAQ3gIQ3hIgDtBjp91v3fnuqAxfmBG5z2lKVCxizKXQDPhGyg2XD0KlJUtYhGXKNdGMYC4kZSoAT66BWgJZlhGJSHiI1ifTiTpCHk0Vk4IqoKKSkCzJwpgnqYDnUx3TSB2jQ1vf4czqoQxdQ5x8l3GK6iVcztCGhq6mzlHtTc4v8ub_BDQXR2Y |
link.rule.ids | 782 |
linkProvider | EBSCOhost |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=A+less+traumatic+catheter+for+coronary+arteriography&rft.jtitle=Catheterization+and+cardiovascular+diagnosis&rft.au=Van+Tassel%2C+R+A&rft.au=Gobel%2C+F+L&rft.au=Rydell%2C+M+A&rft.au=Vlodaver%2C+Z&rft.date=1985-01-01&rft.issn=0098-6569&rft.volume=11&rft.issue=2&rft.spage=187&rft_id=info:doi/10.1002%2Fccd.1810110211&rft_id=info%3Apmid%2F3986900&rft_id=info%3Apmid%2F3986900&rft.externalDocID=3986900 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0098-6569&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0098-6569&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0098-6569&client=summon |