Biomechanical and finite element study of drilling sites for benign lesions in femoral head and neck with curettage, bone-grafting and internal fixation

To evaluate the influence of drilling sites for benign lesions in femoral head and neck with curettage, bone-grafting and internal fixation. Twelve paired formalin-fixed human cadaveric femora were grouped randomly into 2 groups of 6 pairs each, which were group 1 and group 2, and one of each pair o...

Full description

Saved in:
Bibliographic Details
Published in:Mathematical biosciences and engineering : MBE Vol. 16; no. 6; pp. 7808 - 7828
Main Authors: Dou, Bang, Zhang, Fang Fang, Ni, Ming, Dai, Ya Hui, Wang, Zhi Yuan, Qin, Tao, Ma, Wen Qian, Zhu, Wei, Mei, Jiong
Format: Journal Article
Language:English
Published: United States AIMS Press 01-01-2019
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To evaluate the influence of drilling sites for benign lesions in femoral head and neck with curettage, bone-grafting and internal fixation. Twelve paired formalin-fixed human cadaveric femora were grouped randomly into 2 groups of 6 pairs each, which were group 1 and group 2, and one of each pair of femora was grouped randomly to drill an oval-shaped hole in the anterior femoral neck, and the contralateral femur was assigned to drill an oval-shaped hole in the lateral of the proximal femur. Group 1 femora were simulated the operation of curettage, bone-grafting and internal fixation, and group 2 femora were simulated the operation of curettage. Besides, finite element models corresponding to mechanical testing were simulated according to one of the twelve femora, then finite element analysis were done. Wilcoxon signed-rank test was used for statistical analysis, with a p value < 0.05 indicating statistical significance. The simulated operation of curettage decreased the axial stiffness and torsional stiffness of the intact proximal femur significantly, while there was no statistical difference on the degree of the decline between different drilling sites. Although the simulated operation of bone-grafting and internal fixation in different drilling sites increased the axial stiffness and torsional stiffness, only in the case of implanting bones and internal fixation for the lateral cortical drilled hole increased the axial stiffness greatly and made a statistical difference, even more stiff than the intact proximal femur model. Compared with drilling in the anterior femoral neck, a bigger stability could be obtained after drilling in the lateral proximal femur for benign lesions in femoral head and neck with curettage, bone-grafting and internal fixation.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1551-0018
1551-0018
DOI:10.3934/mbe.2019392