Use of Machine Learning to Screen for Acute Respiratory Distress Syndrome Using Raw Ventilator Waveform Data

To develop and characterize a machine learning algorithm to discriminate acute respiratory distress syndrome from other causes of respiratory failure using only ventilator waveform data. Retrospective, observational cohort study. Academic medical center ICU. Adults admitted to the ICU requiring inva...

Full description

Saved in:
Bibliographic Details
Published in:Critical care explorations Vol. 3; no. 1; p. e0313
Main Authors: Rehm, Gregory B, Cortés-Puch, Irene, Kuhn, Brooks T, Nguyen, Jimmy, Fazio, Sarina A, Johnson, Michael A, Anderson, Nicholas R, Chuah, Chen-Nee, Adams, Jason Y
Format: Journal Article
Language:English
Published: United States Lippincott Williams & Wilkins 08-01-2021
Wolters Kluwer
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To develop and characterize a machine learning algorithm to discriminate acute respiratory distress syndrome from other causes of respiratory failure using only ventilator waveform data. Retrospective, observational cohort study. Academic medical center ICU. Adults admitted to the ICU requiring invasive mechanical ventilation, including 50 patients with acute respiratory distress syndrome and 50 patients with primary indications for mechanical ventilation other than hypoxemic respiratory failure. None. Pressure and flow time series data from mechanical ventilation during the first 24-hours after meeting acute respiratory distress syndrome criteria (or first 24-hr of mechanical ventilation for non-acute respiratory distress syndrome patients) were processed to extract nine physiologic features. A random forest machine learning algorithm was trained to discriminate between the patients with and without acute respiratory distress syndrome. Model performance was assessed using the area under the receiver operating characteristic curve, sensitivity, specificity, positive predictive value, and negative predictive value. Analyses examined performance when the model was trained using data from the first 24 hours and tested using withheld data from either the first 24 hours (24/24 model) or 6 hours (24/6 model). Area under the receiver operating characteristic curve, sensitivity, specificity, positive predictive value, and negative predictive value were 0.88, 0.90, 0.71, 0.77, and 0.90 (24/24); and 0.89, 0.90, 0.75, 0.83, and 0.83 (24/6). Use of machine learning and physiologic information derived from raw ventilator waveform data may enable acute respiratory distress syndrome screening at early time points after intubation. This approach, combined with traditional diagnostic criteria, could improve timely acute respiratory distress syndrome recognition and enable automated clinical decision support, especially in settings with limited availability of conventional diagnostic tests and electronic health records.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2639-8028
2639-8028
DOI:10.1097/CCE.0000000000000313