SSEP amplitude accurately predicts both good and poor neurological outcome early after cardiac arrest; a post-hoc analysis of the ProNeCA multicentre study

To assess if, in comatose resuscitated patients, the amplitude of the N20 wave (N20amp) of somatosensory evoked potentials (SSEP) can predict 6-months neurological outcome. Multicentre study in 13 Italian intensive care units. The N20amp in microvolts (μV) was measured at 12 h, 24 h, and 72 h from c...

Full description

Saved in:
Bibliographic Details
Published in:Resuscitation Vol. 163; pp. 162 - 171
Main Authors: Scarpino, Maenia, Lolli, Francesco, Lanzo, Giovanni, Carrai, Riccardo, Spalletti, Maddalena, Valzania, Franco, Lombardi, Maria, Audenino, Daniela, Contardi, Sara, Celani, Maria Grazia, Marrelli, Alfonso, Mecarelli, Oriano, Minardi, Chiara, Minicucci, Fabio, Politini, Lucia, Vitelli, Eugenio, Peris, Adriano, Amantini, Aldo, Grippo, Antonello, Sandroni, Claudio, Bandinelli, Chiara, Bernardo, Pasquale, Cantisani, Teresa Anna, Ciuffini, Roberta, Marudi, Andrea, Cossu, Cesarina, Olivo, Giuseppe, Rikani, Klaudio, Sabadini, Rossella
Format: Journal Article
Language:English
Published: Ireland Elsevier B.V 01-06-2021
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To assess if, in comatose resuscitated patients, the amplitude of the N20 wave (N20amp) of somatosensory evoked potentials (SSEP) can predict 6-months neurological outcome. Multicentre study in 13 Italian intensive care units. The N20amp in microvolts (μV) was measured at 12 h, 24 h, and 72 h from cardiac arrest, along with pupillary reflex (PLR) and a 30-min EEG classified according to the ACNS terminology. Sensitivity and false positive rate (FPR) of N20amp alone or in combination were calculated. 403 patients (age 69[58–68] years) were included. At 12 h, an N20amp >3 μV predicted good neurological outcome (Cerebral Performance Categories [CPC] 1–2) with 61[50−72]% sensitivity and 11[6–18]% FPR. Combining it with a benign (continuous or nearly continuous) EEG increased sensitivity to 91[82−96]%. For poor outcome (CPC 3–5), an N20Amp ≤0.38 μV, ≤0.73 μV and ≤1.01 μV at 12 h, 24 h, and 72 h, respectively, had 0% FPR with sensitivity ranging from 61[51−69]% and 82[76−88]%. Sensitivity was higher than that of a bilaterally absent N20 at all time points. At 12 h and 24 h, a highly malignant (suppression or burst-suppression) EEG and bilaterally absent PLR achieved 0% FPR only when combined with SSEP. A combination of all three predictors yielded a 0[0−4]% FPR, with maximum sensitivity of 44[36−53]%. At 12 h from arrest, a high N20Amp predicts good outcome with high sensitivity, especially when combined with benign EEG. At 12 h and 24 h from arrest a low-voltage N20amp has a high sensitivity and is more specific than EEG or PLR for predicting poor outcome.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0300-9572
1873-1570
DOI:10.1016/j.resuscitation.2021.03.028