Echocardiography-guided percutaneous closure of oval-shaped secundum atrial septal defects
An atrial septal defect (ASD) is considered oval-shaped when its shortest diameter is less than 75% of the longest diameter. Research on percutaneous closure of oval-shaped ASDs is limited, with no known reports of non-fluoroscopic closure for this population. To assess the effectiveness of non-fluo...
Saved in:
Published in: | BMC cardiovascular disorders Vol. 24; no. 1; pp. 534 - 8 |
---|---|
Main Authors: | , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
England
BioMed Central
03-10-2024
BMC |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | An atrial septal defect (ASD) is considered oval-shaped when its shortest diameter is less than 75% of the longest diameter. Research on percutaneous closure of oval-shaped ASDs is limited, with no known reports of non-fluoroscopic closure for this population.
To assess the effectiveness of non-fluoroscopic percutaneous closure for oval-shaped ASDs.
This single-center retrospective study evaluates patients undergoing non-fluoroscopic percutaneous closure of oval-shaped ASDs, defined by the shortest to longest diameter ratio < 0.75, a circular index of 1.33, or ultrasound visualization of an oval shape. Device size was chosen to be 0-4 mm larger than the defect's longest diameter, based on transthoracic and transesophageal ultrasound measurements.
We identified 78 patients (33.3% children, 20.5% males) with a mean age of 27.4 ± 16.3 years and a mean weight of 46.8 ± 19.8 kg. The mean longest diameter and mean shortest diameter of ASDs were 23.3 ± 6.8 mm and 15.8 ± 5 mm, respectively. The mean ratio of the shortest to longest diameter was 0.7 ± 0.1. Percutaneous closure was not attempted in 7/78 (9%) patients. Three out of 71 (4.2%) procedures were fluoroscopy-guided upfront due to technical difficulties, and 5/71 (7%) were converted to fluoroscopy-guided closure. Overall procedural success rate was 98.6% (70/71) including 63/71 (88.7%) performed with zero fluoroscopy. Mean device size was 26.5 ± 7.1 mm. Mean procedural time was 45.3 ± 22.6 min. Eleven intraprocedural complications occurred including 6 arrhythmias, 3 pericardial effusions, and 2 device dislodgements.
Transcatheter closure of oval-shaped ASD is safe and feasible. Echocardiography is adequate for adequate operative guidance. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1471-2261 1471-2261 |
DOI: | 10.1186/s12872-024-04165-7 |