Endoscopic Management of Anchor Erosion Adjacent to the Pylorus Following Duodenal-Jejunal Bypass Sleeve

Introduction Obesity is a pandemic associated with significant comorbidities such as type 2 diabetes (T2DM). RYGB is an effective treatment modality for obesity and T2DM. However, bariatric surgery is currently limited to a relatively small population of patients. The duodenal-jejunal bypass sleeve...

Full description

Saved in:
Bibliographic Details
Published in:Obesity surgery Vol. 29; no. 6; pp. 2003 - 2004
Main Authors: De Moura, Eduardo Guimarães Hourneaux, de Moura, Diogo Turiani Hourneaux, Galvão-Neto, Manoel, Sakai, Christiano Makoto, Silva, Gustavo Luis Rodela, Bazarbashi, Ahmad Najdat, Thompson, Christopher C.
Format: Journal Article
Language:English
Published: New York Springer US 01-06-2019
Springer Nature B.V
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Introduction Obesity is a pandemic associated with significant comorbidities such as type 2 diabetes (T2DM). RYGB is an effective treatment modality for obesity and T2DM. However, bariatric surgery is currently limited to a relatively small population of patients. The duodenal-jejunal bypass sleeve (DJBS) has recently emerged as a promising therapy for obesity and T2DM by providing similar physiological effects to RYGB. We describe a case of a patient with a previously placed DJBS presenting with abdominal pain from anchor erosion managed with an endoscopic approach. Methods A 58-year-old man with obesity and T2DM who had failed prior medical therapy for obesity was referred for DJBS placement. This was placed without complications. At 8 weeks follow-up, he developed abdominal pain and vomiting prompting immediate endoscopic evaluation. Results EGD revealed an anchor erosion resulting in mild stenosis of the pylorus. Additionally, hyperplastic tissue was found to be adhered to the device in the duodenal bulb. Endoscopic removal with balloon dilation was unsuccessful, and a stent was placed in a “stent-in-stent” fashion through the sleeve to compress the area of tissue ingrowth encouraging local tissue necrosis and device extraction. At 15 days follow-up, the stent was removed; however, the DJBS remained adhered and immobile. Next, the ingrowing hyperplastic tissue was resected in a piecemeal fashion. This resulted in mobilization of the sleeve anchors in the duodenal bulb and successful removal of the DJBS. Conclusions DJBS endoscopic removal is safe and effective even in challenging cases, thus preventing the need for surgical intervention.
Bibliography:ObjectType-Case Study-3
SourceType-Scholarly Journals-1
content type line 23
ObjectType-Feature-5
ObjectType-Undefined-1
ObjectType-Report-2
ObjectType-Article-4
ISSN:0960-8923
1708-0428
DOI:10.1007/s11695-019-03855-y