Brazilian Translation, Cross-Cultural Adaptation, Validity, and Reliability of the EMpowerment of PArents in THe Intensive Care 30 (EMPATHIC-30) Questionnaire to Measure Parental Satisfaction in PICUs
OBJECTIVESTo conduct the Brazilian translation, cross-cultural adaptation, validation, and reliability testing of the EMpowerment of PArents in THe Intensive Care (EMPATHIC-30). DESIGNProspective study. SETTINGPICU of a tertiary-care teaching hospital. PATIENTSParents (n = 141) completed the transla...
Saved in:
Published in: | Pediatric critical care medicine Vol. 22; no. 6; pp. e339 - e348 |
---|---|
Main Authors: | , , , , , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Lippincott Williams & Wilkins
01-06-2021
|
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | OBJECTIVESTo conduct the Brazilian translation, cross-cultural adaptation, validation, and reliability testing of the EMpowerment of PArents in THe Intensive Care (EMPATHIC-30). DESIGNProspective study. SETTINGPICU of a tertiary-care teaching hospital. PATIENTSParents (n = 141) completed the translated EMPATHIC-30 questionnaire 72 hours after their child's PICU discharge. INTERVENTIONSNone. MEASUREMENTS AND MAIN RESULTSThe translation and cultural adaptation were performed in accordance with the principles of good practice for the translation and cultural adaptation process for patient-reported outcomes measures. Sentences were adapted according to the Brazilian syntax. Total content validity coefficient was above the established average (> 0.8). Reliability was evaluated with the coefficients McDonald omega and Cronbach alpha. The lowest Cronbach alpha found was 0.47 (CI 95%, 0.35-0.59) in the organization domain, where the lowest response rate was also concentrated. The values of the other domains were as follows: 0.64 (95% CI, 0.55-0.73) for information, 0.77 (95% CI, 0.71-0.83) for care and treatment, 0.72 (95% CI, 0.66-0.78) for parent participation, and 0.72 (95% CI, 0.65-0.79) for professional attitudes. The total internal consistency independent of the domain was 0.90 (CI 95%, 0.88-0.92). With regard to McDonald Omega, values were identified: 0.68 (95% CI, 0.49-0.88) for information, 0.73 (95% CI, 0.61-0.85) for care and treatment, 0.85 (95% CI, 0.47-0.80) for parent participation, 0.85 (95% CI, 0.76-0.93), and 0.72 (95% CI, 0.58-0.86) for professional attitudes. CONCLUSIONSEMPATHIC-30 has been translated and culturally adapted for the Brazilian population. Validation demonstrated an above-average total content validity coefficient, confirming the instrument content validity. A sufficient reliability was observed in both analyzed coefficients. The results support the use of the Brazilian version of EMPATHIC-30 for the evaluation of parents' satisfaction of children admitted to the PICU. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1529-7535 |
DOI: | 10.1097/PCC.0000000000002594 |