Risk Factors and Techniques for Safe Pectus Bar Removal in Adults After Modified Nuss Repair

The Nuss repair involves implants designed for removal after 2 to 3 years. Although rare, significant complications can occur with bar removal, and the incidence of these complications may be higher in adults. This study was performed to review complications and risk factors associated with bar remo...

Full description

Saved in:
Bibliographic Details
Published in:The Annals of thoracic surgery Vol. 116; no. 4; pp. 787 - 794
Main Authors: Aly, Mohamed R., Farina, Juan M., Bostoros, Peter M., Botros, Michael M., Pulivarthi, Venkata S., Peterson, Michelle A., Lackey, Jesse J., Jaroszewski, Dawn E.
Format: Journal Article
Language:English
Published: Netherlands Elsevier Inc 01-10-2023
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The Nuss repair involves implants designed for removal after 2 to 3 years. Although rare, significant complications can occur with bar removal, and the incidence of these complications may be higher in adults. This study was performed to review complications and risk factors associated with bar removal and discuss strategies to improve operative safety. A retrospective study was performed including all patients after pectus excavatum repair who underwent Nuss implant removal at Mayo Clinic Arizona (Phoenix, AZ) from 2013 to 2022. In total, 1555 bars were removed (683 patients; 71% men; median age, 34 years[(range, 15-71 years]). Of the removals, 12.45% of patients had bars placed at outside institutions. Major complications were rare, with bleeding most common (2.05%), followed by pneumothorax (0.88%), infection (0.59%), and effusions (0.44%). Most major bleeding (85.71%) occurred from the bar track during removal and was controlled by packing the track. One patient required subsequent hematoma evacuation and transfusion. Bleeding secondary to lung injury was also successfully controlled with packing. Bar removal in 1 patient with significantly displaced bars required sternotomy and cardiopulmonary bypass as a result of aortic injury. Risk factors identified for bleeding included sternal erosion (P < .001), bar migration (P < .001), higher number of bars (P = .037), and revision of a previous pectus repair (P = 0.001). Bar migration was additionally associated with major complications (P < .001). Older age, although a risk factor for overall complications (P = 0.001), was not a risk factor for bleeding. Bar removal can be safely performed in most patients; however, significant complications, including bleeding, may occur. Identifying potential risk factors and being prepared for rescue maneuvers are critical to prevent catastrophic outcomes. [Display omitted]
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0003-4975
1552-6259
DOI:10.1016/j.athoracsur.2022.11.038