Comparison between two methods for cardiac output measurement in propofol-anesthetized dogs: thermodilution and Doppler

To compare cardiac output (CO) measured by Doppler echocardiography and thermodilution techniques in spontaneously breathing dogs during continuous infusion of propofol. To do so, CO was obtained using the thermodilution method (CO(TD)) and Doppler evaluation of pulmonary flow (CO(DP)) and aortic fl...

Full description

Saved in:
Bibliographic Details
Published in:Veterinary anaesthesia and analgesia Vol. 37; no. 5; p. 401
Main Authors: Lopes, Patricia Cristina Ferro, Sousa, Marlos Gonçalves, Camacho, Aparecido Antonio, Carareto, Roberta, Nishimori, Celina T D, Santos, Paulo S P, Nunes, Newton
Format: Journal Article
Language:English
Published: United States 01-09-2010
Subjects:
Online Access:Get more information
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To compare cardiac output (CO) measured by Doppler echocardiography and thermodilution techniques in spontaneously breathing dogs during continuous infusion of propofol. To do so, CO was obtained using the thermodilution method (CO(TD)) and Doppler evaluation of pulmonary flow (CO(DP)) and aortic flow (CO(DA)). Prospective cohort study. Eight adult dogs weighing 8.3 +/- 2.0 kg. Propofol was used for induction (7.5 +/- 1.9 mg kg(-1) IV) followed by a continuous rate infusion at 0.7 mg kg(-1) minute(-1). The animals were positioned in left lateral recumbency on an echocardiography table that allowed for positioning of the transducer at the 3rd and 5th intercostal spaces of the left hemithorax for Doppler evaluation of pulmonary and aortic valves, respectively. CO(DP) and CO(DA) were calculated from pulmonary and aortic velocity spectra, respectively. A pulmonary artery catheter was inserted via the jugular vein and positioned inside the lumen of the pulmonary artery in order to evaluate CO(TD). The first measurement of CO(TD), CO(DP) and CO(DA) was performed 30 minutes after beginning continuous infusion (T0) and then at 15-minute intervals (T15, T30, T45 and T60). Numeric data were submitted to two-way anova for repeated measurements, Pearson's correlation coefficient and Bland & Altman analysis. Data are presented as mean +/- SD. At T0, CO(TD) was lower than CO(DA). CO(DA) was higher than CO(TD) and CO(DP) at T30, T45 and T60. The difference between the CO(TD) and CO(DP), when all data were included, was -0.04 +/- 0.22 L minute(-1) and Pearson's correlation coefficient (r) was 0.86. The difference between the CO(TD) and CO(DA) was -0.87 +/- 0.54 L minute(-1) and r = 0.69. For CO(TD) and CO(DP), the difference was -0.82 +/- 0.59 L minute(-1) and r = 0.61. Doppler evaluation of pulmonary flow was a clinically acceptable method for assessing the CO in propofol-anesthetized dogs.
ISSN:1467-2995
DOI:10.1111/j.1467-2995.2010.00552.x